2-9
VPL-HW10
2-7-2. SUB CPU Upgrade
1.
Double-click Flash.exe to start the application.
Application name:
Main Flash upgrader for Sony
Projector
Execution file name: Flash.exe
n
When starting the application first, the following errors
may appear. But, continue the procedure.
“No. 300:
No information file was found.”
“No. 711:
No download file was found.”
2.
Click the [Select] button to select download informa-
tion file.
The file open window appears.
3.
Select the download information file.
File to be selected
(HW10/HW15): (hh1v
****.dli/hh2v****.dli)
(
**** means version number. Example: hh1v001a.dli)
4.
Click the [Setting] button of the “Com.”.
5.
Set the following items.
Bit rate:
38,400 bit/s
Serial port: Serial port number used for connecting
PC
Time out:
Arbitrary
(Communication retrial time. default: 5
sec.)
6.
Select “User Program Mode”.
7.
Click the [Start] button.
The start window appears.
8.
Click the [OK] button.
The “Please AC Plug In” window appears.
9.
Connect the AC plug.
10. Comfirm the Standby Mode is set to “Standard”.
(Refer to “Preparation” in Section 2-7-1.)
11. Click the [OK] button.
The writing starts and the write window appear.
12. The end window appears. (Upgrade completed)
2-10
VPL-HW10
2-7-3. Scan Converter Upgrade
1.
Connect the AC plug and set this unit to standby state.
2.
Comfirm the Standby Mode is set to “Standard”.
(Refer to “Preparation” in Section 2-7-1.)
3.
Double-click FlashUpgraderForSony35.exe to start the
application.
Application name:
Pixelworks FlashUpgrader
Execution file name: FlashUpgraderForSony35.exe
Version:
3.5 or later
4.
Select the COM port to COM port number used for
connecting PC.
5.
Select the Baud Rate to “115200”.
6.
Click the [Choose...] button.
The file selection window appears.
7.
Select the upgrade file.
File to be selected (HW10/HW15): pw0p
****.inf
(
**** means version number. Example: pw0p100a.inf)
8.
Check that the two hex files appear on the Files To
Download field.
9.
Click the [Ext|_|232C|PW|_|1] button.
10. Click the [Flash] button.
The upgrading starts and the status bar appears. And
the [Flash] button changes to the [Cancel] button.
11. After completed, check that the [Cancel] button
changes to the [Flash] button.
12. Disconnect the AC plug.
2-11
VPL-HW10
2-7-4. Data Write Method of LookUpTable/3Dgamma/DDC/OGMTable/
CSMatrixTable
1.
Connect the AC plug and set this unit to standby state.
2.
Comfirm the Standby Mode is set to “Standard”.
(Refer to “Preparation” in Section 2-7-1.)
3.
When LookUpTable or 3Dgamma data writing, press
the [ON/STANDBY] button to light the lamp.
4.
Double-click QuickAccess.exe to start the application.
Application name:
3Dgamma QuickAccess
Execution file name: QuickAccess.exe
Version:
8.20 or later
5.
Select “VPL-HW10” or “VPL-HW15” on the Model
pull-down menu.
6.
Select Load on the Load/Save pull-down menu.
7.
Select the data type (3Dgamma/LookUpTable/DDC/
OGMTable/CSMatrixTable) on the 3dgm/Lut pull-
down menu.
8.
Click the [Next] button.
9.
Select the serial port used for connecting PC on the
Serial Port pull-down menu.
Upper box: Serial port number used for connecting PC
Lower box: 38400
10. Click the [Next] button.
11. Select “ALL” on the Load field.
12. Check the Verify check box.
13. Click the [Browse...] button and select the data file to
be written.
14. Click the [Next] button.
The massage “There is a wrong file. To continue push
YES.” appears.
15. Click the [YES] button.
The writing is performed.
When completed, the massage “Turn Off and On the
AC and then Power On to enable the new settings.”
appears.
16. Click the [OK] button.
17. Turn off the power and disconnect and connect the AC
plug, to restart this unit.
18. Click the [Complete] button.
2-12
VPL-HW10
2-7-5. Data Obtain Method of LookUpTable/3Dgamma/DDC/OGMTable/
CSMatrixTable from the Board
1.
Connect the AC plug and set this unit to standby state.
2.
Double-click QuickAccess.exe to start the application.
Application name:
3Dgamma QuickAccess
Execution file name: QuickAccess.exe
Version:
8.10 or later
3.
Select “VPL-HW10” or “VPL-HW15” on the Model
pull-down menu.
4.
Select Save on the Load/Save pull-down menu.
5.
Select the data type (3Dgamma/LookUpTable/DDC/
OGMTable/CSMatrixTable) on the 3dgm/Lut pull-
down menu.
6.
Click the [Next] button.
7.
Select the serial port used for connecting PC on the
Serial Port pull-down menu.
Upper box: Serial port number used for connecting PC
Lower box: 38400
8.
Click the [Next] button.
9.
Select “SAVE_ALL” on the Save field.
10. Check the Verify check box.
11. Type an arbitrary file name on the File Name field.
12. Click the [Next] button.
The saving is performed.
When completed, the massage “Verify Success!
Reading Model Name, Serial Number, NVM Map
Version and NVM Data Version is successful.”
appears.
13. Click the [OK] button.
14. Turn off the power of this unit.
15. Click the [Complete] button.
Page of 127