DOWNLOAD Sony RM-PJ2 / RM-PJM12 / VPL-CS5A / VPL-CS6 / VPL-CX6 / VPL-EX1 Service Manual ↓ Size: 8.64 MB | Pages: 124 in PDF or view online for FREE

Model
RM-PJ2 RM-PJM12 VPL-CS5A VPL-CS6 VPL-CX6 VPL-EX1
Pages
124
Size
8.64 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector
File
rm-pj2-rm-pjm12-vpl-cs5a-vpl-cs6-vpl-cx6-vpl-ex1.pdf
Date

Sony RM-PJ2 / RM-PJM12 / VPL-CS5A / VPL-CS6 / VPL-CX6 / VPL-EX1 Service Manual ▷ View online

2-1
VPL-CS5A/CS6/CX6/EX1
Section 2
Electrical Adjustments
9.
Tighten the adjustment plate fixing screw.
10. Tighten the six adjustment plate fixing screws manual-
ly with a torque driver.
Tightening torque: 0.19 
±
0.03 Nm
11. Check to see that the illumination range error is within
the tolerable limit.
When installing the optical unit in this model, alignment of
the gear tooth position is required. Perform the following
steps.
Procedure
1.
Rotate the lens focus and zoom in the fully clockwise
positions. Lock the lens gear in the direction shown in
Fig. 1.
Fig. 1
Lens projection
Lens gear
Gear alignment portion
Lens gear
Lens gear
Zoom
Focus
2-1. Preparation
2-1-1. Required Equipment
. Oscilloscope
Sony Tektronix 2465 or equivalent (350 MHz band
width or more)
. NTSC, PAL, SECAM component signal generator
Sony Tektronix TG2000 
+ AVG1 (option module) +
AWVG1 (option module) or equivalent
. VG (programmable video signal generator)
VG814 or equivalent
. Digital voltmeter
Advantest TR6845 or equivalent
. Illuminance meter
n
Allow the warm-up time of 5 minutes after the power is on
before starting the following adjustments.
2-1-2. Opt Unit Adjustment
Rotate the cooling fan and turn on the lamps.
(1) Mirror adjustment
Adjust the screen size to 80 inch at the WIDE end.
1.
Select the green only mode.
2.
Check to see if there is any black zone at the top,
bottom, left or right of screen. If there is any black
zone on screen, loosen the adjustment plate fixing
screw and adjust the G dichroic mirror for minimum
black zone.
3.
Tighten the adjustment plate fixing screw.
4.
Select the cyan only mode.
5.
Check to see if there is any black zone at the top,
bottom, left or right of screen. If there is any black
zone on screen, loosen the adjustment plate fixing
screw and adjust the RB mirror adjustment plate for
minimum black zone and the blue color is distinguish-
ing.
6.
Tighten the adjustment plate fixing screw.
7.
Select the all white mode.
8.
Check to see if there is any black zone at the top,
bottom, left or right of screen. If there is any black
zone on screen, loosen the adjustment plate fixing
screw and adjust the RB mirror adjustment plate for
minimum black zone and the red color is distinguish-
ing.
2-2
VPL-CS5A/CS6/CX6/EX1
2.
Align the marking position of the lens zoom gear with
the protrusion of the lens gear approximately by visual
observation as shown below.
Fig. 2 (inside view)
Confirmation
Install the side panel and confirm that the portions A and
B of the dial cannot be seen from the opening of the side
panel when the ZOOM and FOCUS are moved to their
very ends.
Zoom gear
Lens gear
Protrusion
Rib for marking
2-1-3. How to Enter the Factory Mode
1.
Confirm that the MENU can be displayed.
2.
Close the MENU.
3.
Press the keys in the following order : [ENTER] 
[ENTER] 
→ 
[&] 
 [ENTER].
The message [Do you want to enter the Factory Mode?
Yes : 
↑ 
 No : 
] appears.
Select [Yes : 
].
[Supplementary information: How to Exit the
Factory Mode]
Perform the step 3 KEY operation.
The message [Do you want to return to the User Mode?
Yes : 
↑ 
 No : 
] appears.
Select [Yes : 
].
n
In the Factor mode, you can close the lens shutter if you
keep pressing the TILT key even though the lamp lights.
If the machine is left in this state for long hours, the lens
shutter may melt in the worst case. Be sure to confirm that
the lens shutter is not closed when the lamp lights in the
Factory mode.
2-2. V COM Adjustment
1.
Input the green-only, 30 IRE single-line ON/OFF
signal to the input connector.
(VPL-CS5A/CS6: SVGA signal, VPL-CX6/EX1 :
XGA signal)
2.
Enter the G VCOM adjustment screen of the Device
Adjust.
3.
Adjust the G VCOM value so that the flicker is
minimal.
4.
Switch the input signal from green-only to red-only
then to blue only single-line ON/OFF signal. In the
same way as step 3, adjust the R VCOM and B VCOM
values respectively so that the flicker is minimal.
5.
Take note of the adjustment values.
6.
Set the “Image Flip” to either V or HV.
7.
Input the above R/G/B adjustment values.
8.
Take note of the adjustment values.
9.
Set the “Image Flip” to OFF.
B
A
ZOOM FOCUS
ZOOM FOCUS
Good
No good
2-3
VPL-CS5A/CS6/CX6/EX1
2-3. Initial Values of Adjustment Items
VPL-CS5A/CS6/CX6/EX1
MenuTitle
ItemName
MemoryName
Remark
Set Memory
Picture Memory
W/B Memory
Video
S Video
Input-A
MS
Video
Computer
Dynamic Standard Dynamic Standard Dynamic Standard Dynamic Standard High Low High Low
PICTURE SETTING Picture Mode
Standard
Adjust Picture...
Contrast
95
80
95
80
95
80
95
80
Brightness
40
50
40
50
40
50
40
50
Color
50
50
50
50
50
50
-
-
Hue
50
50
50
50
-
-
-
-
Sharpness
Middle
Middle
Middle
Middle
Middle
Middle
-
-
RGB Enhancer
-
-
-
-
20
20
20
20
Gamma Mode
-
-
-
-
Graphics Graphics Graphics Graphics
Color Temp.
Low
Low
Low
Low
High
High
High
High
Volume
30
INPUT SETTING
Adjust Signal...
Dot Phase
15(*1)
H Size
(*1)
Shift
(*1)
Wide Mode
Off
Off
Off
Off
Off
Off
Off
Off
Scan Conv
On
On
SET SETTING
Smart  APA
On
Auto Input Search
Off
Input-A Signal Sel.
Computer
Color System
Auto
Power Saving
Off
IR Reciever
Front & Rear
Illumination
On
MENU SETTING
Status
On
Languege
English
Menu Position
Center
Menu Color
White
INSTALL SETTING Tilt...
V Keystone
Auto
Manual...
0
Image Flip
Off
Background
Blue
Lamp Mode(*2)
Standard
High Altitude
Off
Security Lock
Off
Key
Enter x 4
Status
Memory
2-4
VPL-CS5A/CS6/CX6/EX1
(VPL-CS5A/CS6/CX6/EX1)
MenuTitle
ItemName
MemoryName
Remark
Set Memory
Picture Memory
W/B Memory
Video
S Video
Input-A
MS
Video
Computer
Dynamic Standard Dynamic Standard Dynamic Standard Dynamic Standard High Low High Low
INFORMATION
fH
Display only
fV
Display only
(Memory No.)
Display  only
(Resolution)
Display only
Lamp Timer
Display only
ROM Version
Display  only
SC ROM Version
Display only
Operation Timer
Display only
Prev. Lamp Timer
Display only
W/B SETTING
Gain R
182
182
160
160
     G
182
150
160
140
     B
182
160
160
150
Bias R
85
85
85
85
     G
85
85
85
85
     B
85
85
85
85
*1 The
 "
Dot Phase E,H Size,Shift H/V and Picture Mode" items in the "INPUT SETTING" menu have their respective initial values for each input signal(PRESET MEMORY No.).
*2 VPL-CS5A is not indicated.
There are some adjustment items that cannot be adjusted, depending on the input signal.
Status
Memory
Page of 124
Display