DOWNLOAD Sony DPF-VR100 / DPF-XR100 / DPF-XR80 Service Manual ↓ Size: 2.08 MB | Pages: 18 in PDF or view online for FREE

Model
DPF-VR100 DPF-XR100 DPF-XR80
Pages
18
Size
2.08 MB
Type
PDF
Document
Service Manual
Brand
Device
Service Manual / Other
File
dpf-vr100-dpf-xr100-dpf-xr80.pdf
Date

Sony DPF-VR100 / DPF-XR100 / DPF-XR80 Service Manual ▷ View online

DPF-XR80/XR100/VR100
– 9 –
1-2.  ACCESSORIES
– ENGLISH –
The  components  identified  by  mark  0  or 
dotted line with mark 0 are critical for safety.
Replace only with part number specified.
Les composants identifiés par une marque 
0
 sont critiques pour la sécurité.
Ne les remplacer que par une pièce portant 
le numéro spécifié.
Remote control
(RMT-DPF8)
DPF-XR100/VR100
1-489-219-21
Stand
DPF-XR100/VR100
4-199-171-01
Screw
DPF-XR100/VR100
4-199-206-01
Conversion (2P) Adaptor
DPF-VR100
0
1-569-007-12 (JE)
Conversion (2P) Adaptor
DPF-XR100
0
1-569-008-12 (E (Central & South America))
Hanging unit on the wall
DPF-XR100
4-193-989-01
DPF-VR100
4-193-989-01 (BLACK)
4-193-989-11 (WHITE)
AC adaptor
DPF-XR100
0
1-489-221-11 (US, CND, TW)
0
1-489-221-31 (CH (BLACK))
0
1-489-221-61 (AEP (BLACK), EE (BLACK), RUS (BLACK), E (EXCEPT Saudi, Hong Kong))
0
1-489-221-81 (UK (BLACK), E (Saudi, Hong Kong))
0
1-489-289-31 (CH (SILVER))
0
1-489-289-61 (AEP (SILVER), EE (SILVER), RUS (SILVER))
0
1-489-289-81 (UK (SILVER))
DPF-VR100
0
1-489-221-11 (US, CND, JE)
0
1-489-221-31 (CH (BLACK))
0
1-489-221-41 (KR)
0
1-489-221-51 (AUS)
0
1-489-221-61 (AEP (BLACK), EE (BLACK), RUS (BLACK))
0
1-489-221-81 (UK (BLACK))
0
1-489-221-91 (BR)
0
1-489-289-31 (CH (WHITE))
0
1-489-289-61 (AEP (WHITE), EE (WHITE), RUS (WHITE))
0
1-489-289-81 (UK (WHITE), E)
Operating Instructions
(Only for destination Japanese model)
英語,韓国語,中国語のみ部品供給可能です。
4-259-434-11 (ENGLISH)
*
4-259-434-21
(FRENCH)
*
4-259-434-31
(GERMAN)
*
4-259-434-41 (DUTCH)
*
4-259-434-51 (ITALIAN)
*
4-259-434-61 (SPANISH)
*
4-259-434-71 (PORTUGUESE)
*
4-259-434-81 (RUSSIAN)
*
4-259-434-91 (UKRAINIAN)
*
4-259-435-11 (ARABIC)
*
4-259-435-21 (PERSIAN)
4-259-435-31 (KOREAN)
*
4-259-435-41 (SIMPLIFIED CHINESE)
(JE (DPF-VR100), E (Saudi, Hong Kong))
*
4-259-435-51 (TRADITIONAL CHINESE)
4-259-435-61 (SIMPLIFIED CHINESE) (CH)
CD-ROM
4-256-957-01
*
4-259-436-01 (JAPANESE)
*
4-259-436-11 (ENGLISH)
*
4-259-436-21 (FRENCH)
*
4-259-436-31 (GERMAN)
*
4-259-436-41 (DUTCH)
*
4-259-436-51 (ITALIAN)
*
4-259-436-61 (SPANISH)
*
4-259-436-71 (PORTUGUESE)
*
4-259-436-81 (RUSSIAN)
*
4-259-436-91 (UKRAINIAN)
*
4-259-437-11 (ARABIC)
*
4-259-437-21 (PERSIAN)
*
4-259-437-31 (KOREAN)
*
4-259-437-41 (SIMPLIFIED CHINESE)
*
4-259-437-51 (TRADITIONAL CHINESE)
The CD-ROM supplied contains all of language version of
the Instruction Manual in pdf (Digital Photo Frame Handbook.pdf)
for printing.
・The printed matter is not supplied. If required,
please order it with the part number below.
・(Only for destination Japanese model)
  日本国内については日本語のみが印刷での部品供給可能です。
Digital Photo Frame Handbook
Digital Photo Frame Handbook
*
4-259-437-41 (SIMPLIFIED CHINESE) (CH)
DPF-XR80/XR100/VR100
– 10 –
1-2.  付属品
– JAPANESE –
0
印の部品,または0印付の点線で囲ま
れた部品は,安全性を維持するために,
重要な部品です。
従って交換時は,必ず指定の部品を使用
してください。
デジタルフォトフレーム 
ハンドブック
*
4-259-436-01
(日本語)
スタンド
DPF-XR80/XR100
4-199-171-01
ネジ
DPF-XR80/XR100
4-199-206-01
壁掛けユニット
DPF-XR80/XR100
4-193-989-01
ACアダプタ
DPF-XR80/XR100
0
1-489-221-11 (BLACK)
0
1-489-289-11 (SILVER)
リモコン
(RMT-DPF8)
DPF-XR80/XR100
1-489-219-11
印刷用の
デジタルフォトフレーム ハンドブック (PDF)は,全て
の言語が付属品のCD-ROMに含まれています。
・印刷物は付属されておりません。
 必要な場合は下記部品番号にて注文となります。
・ 日本国内については日本語のみが印刷での部品供給可能です。
デジタルフォトフレーム ハンドブック
*
4-259-436
-01 (日本語)
*
4-259-436
-11 (英語)
*
4-259-436
-21 (フランス語)
*
4-259-436-31 (ドイツ語)
*
4-259-436-41 (オランダ語)
*
4-259-436-51 (イタリア語)
*
4-259-436-61 (スペイン語)
*
4-259-436-71 (ポルトガル語)
*
4-259-436-81 (ロシア語)
*
4-259-436-91 (ウクライナ語)
*
4-259-437-11 (アラビア語)
*
4-259-437-21 (ペルシャ語)
*
4-259-437-31 (韓国語)
*
4-259-437-41 (中国語 (簡体字))
*
4-259-437-51 (中国語 (繁体字))
取扱説明書
・日本語,英語,韓国語,中国語のみ部品供給可能です。
4-259-434-01 (日本語)
4-259-434-11 (英語)
*
4-259-434-21 (フランス語)
*
4-259-434-31 (ドイツ語)
*
4-259-434-41 (オランダ語)
*
4-259-434-51 (イタリア語)
*
4-259-434-61 (スペイン語)
*
4-259-434-71 (ポルトガル語)
*
4-259-434-81 (ロシア語)
*
4-259-434-91 (ウクライナ語)
*
4-259-435-11 (アラビア語)
*
4-259-435-21 (ペルシャ語)
4-259-435-31 (韓国語)
*
4-259-435-41 (中国語 (簡体字))
(E (Saudi, Hong Kong))
*
4-259-435-51 (中国語 (繁体字))
4-259-435-61 (中国語 (簡体字)) (CH)
下記に参考として,海外向取扱説明書の
部品番号と言語について記載しています。
CD-ROM
4-256-957-01
DPF-XR80/XR100/VR100
– 11 –
– ENGLISH –
2. WRITING OF FIRMWARE
The following procedures are used in DPF-XR100 model.
Conduct the same adjustment for the other models.
2-1.  METHOD OF WRITING OF FIRMWARE
Execute writing the latest firmware when the MAI-010 PC Board Assy 
(Service) was replaced.
If the firmware is not written, normal operation is not done.
Note:  Execute the following procedure in order: WRITING OF SUB CPU, PRE 
UPDATE, WRITING OF FIRMWARE and CHANGE THE DESTINA-
TION.
Preparation
1.  Ready the SD card or SDHC card which capacity is 32GB or less. 
(hereinafter referred to as “the SD card”) 
2.  Format  it  by  using  “SD  Formatter  3.0  (or  later)  for  SD/SDHC/
SDXC”  providing via a URL below.
http://www.sdcard.org/consumers/
Note:  Do not use the SD card formatted without tool above. Updater may cause 
abnormal operations.
3.  Download the following three files from the ESI homepage.
•  DPF_ALEX99_2010XXXX.zip (for pre update)
•  SDUPDATER_2010XXXX.zip (photo frame firmware)
•  SUBCPUXX_2010XXXX.zip (sub CPU)
Note:  Download latest files.
4.  Decompress the zip files downloaded.
2-1-1. WRITING OF SUB CPU
Procedure
1.  Copy  SUBCPUXX.VUP  created  by  the  decompression  of 
SUBCPUXX_2010XXXX.zip onto the root directory of the SD 
card. (most significant hierarchy)
Note:  Do not copy the file except SUBCPUXX.VUP.
2.  Insert the SD card into the SD card slot on the back surface of the 
photo frame.
3.  Insert the plug of the AC adaptor of accessories into outlet.
4.  Insert the plug of the AC adaptor into DC IN 9V terminal on the 
back surface of the photo frame while pressing the [VIEW MODE] 
button to turn on the power.
5.  Release the [VIEW MODE] button when a “S-Frame” logo appears.
6.  When the maintenance mode screen appears, move the cursor to 
“Update firmware” by pressing the [V] [v] button, and press the 
[ENTER] button. (Fig. 2-1-1)
8.  After displaying a version screen, confirm whether the “Updated 
version” is the same as the version that has been described in the 
homepage of ESI, and press the [ENTER] button. (Fig. 2-1-3)
9.  After displaying “Completed.”, unplug the AC adapter to turn off 
the power. (Fig. 2-1-4)
Note:  Power cannot be turned off by pressing the 1 (on/standby) button.
10.  Press the [RESET] button on the back surface of the photo frame 
by using small needle.
11.  Insert the plug of the AC adaptor into DC IN 9V terminal on the 
back surface of the photo frame while pressing the [MENU] button 
and [ENTER] button to turn on the power.
12.  Release the [MENU] button and [ENTER] button when a “S-Frame” 
logo appears.
6.  When the maintenance mode screen appears, move the cursor to 
“Update firmware” by pressing the [V] [v] button, and press the 
[ENTER] button. (Fig. 2-1-7)
7.  When a “Checking the update file.” appears, release the [ENTER] 
button. (Fig. 2-1-8)
8.  When the version up screen appears, confirm the figure of “Updated 
version” is 99.99, and press the [ENTER] button. (Fig. 2-1-9)
13.  After displaying an initial screen of the service mode, move the 
cursor to “System Info” by pressing the [V] [v] button, and press 
the [ENTER] button. (Fig. 2-1-5)
15.  Press the [BACK] button to return to the initial screen of the service 
mode.
16.  Turn off the power pressing the 1 (on/standby) button for a second.
17.  Remove the SD card from the photo frame.
2-1-2. PRE UPDATE
Procedure
1.  Delete 
SUBCPUXX.VUP
 from the SD card.
2.  Copy  DPF_ALEX99.VUP  created  by  the  decompression   
of  DPF_ALEX99_2010XXXX.zip  in  the  folder  of  DPF_
ALEX99_2010XXXX onto the root directory of the SD card. (most 
significant hierarchy)
Note:  Do not copy the files except DPF_ALEX99.VUP.
3.  Insert the SD card into the SD card slot on the back surface of the 
photo frame.
4.  Turn  on  the  1  (on/standby)  button  while  pressing  the  [VIEW 
MODE] button.
5.  Release the [VIEW MODE] button when a “S-Frame” logo appears.
14.  Confirm whether the version of the “subcpu” of “Partition Info” is 
the same figure as the version of the firmware that has been described 
in the homepage of ESI. (Fig. 2-1-6)
Maintenance mode
Update firmware
Initialize system
Fig. 2-1-7
Fig. 2-1-8
Checking the update file.
Insert the memory card and
press [ENTER].
Fig. 2-1-9
Press [ENTER] to update
the firmware.
Updated version :99.99
Current version :1.00
Maintenance mode
Update firmware
Initialize system
Fig. 2-1-1
Fig. 2-1-2
Checking the update file.
Insert the memory card and
press [ENTER].
Fig. 2-1-3
Press [ENTER] to update
the firmware.
Updated version :1.04
Current version :1.04
Fig. 2-1-4
Completed.
Restart the Digital Photo Frame.
System Info
System Setting
Media Check
USB Host Test
Electric Test
Electric Test
Frame Angle : 0
CHECKSUM: XXXXXXXX (H)
DATE: SEP 9 2010 14:39:13
USB SERIAL NO: XXXXXXXX
DPF-XR100 (XX)
Fig. 2-1-5
Button Test
[ Test History ]
Card Test
Set Default
OK
OK
OK
USB Test
CEC Test
Format NAND
LCD W/B
R offset :0 B offset :0
[ Partition Info ]
subcpu : ver 01.04
updater : ver 1.00
uboot : 2010/08/30 11:09
dpf/demo : 2010/07/20 20:44:52
dpf/sound : 2010/07/20 11:20:14
dpf/other : 2010/09/07 16:31:20
OK
OK
OK
Fig. 2-1-6
7.  When a “Checking the update file.” appears, release the [ENTER] 
button. (Fig. 2-1-2)
Fig. 2-1-10
Completed.
Restart the Digital Photo Frame.
9.  When a “Completed.” appears, turn off the power pressing the 1 
(on/standby) button for about a second. (Fig. 2-1-10)
10.  Remove the SD card from the photo frame.
DPF-XR80/XR100/VR100
– 12 –
– ENGLISH –
8.  When a “Completed.” appears, turn off the power pressing the 1 
(on/standby) button for about a second. (Fig. 2-1-14)
9.  Turn on the 1 (on/standby) button while pressing the [MENU] 
button and [ENTER] button.
10.  Release the [MENU] button and [ENTER] button when a “S-Frame” 
logo appears.
11.  After  displaying  an  initial  screen  of  the  service  mode,  confirm 
whether the figure of “CHECKSUM” (hexadecimal number) is the 
same as the version of the firmware that has been described in the 
homepage of ESI. (Fig. 2-1-15)
Note:  It takes about 20 seconds from displaying an initial screen to displaying 
CHECKSUM.
12.  Turn off the power pressing the 1 (on/standby) button for about a 
second and unplug the AC adaptor.
13.  Remove the SD card from the photo frame.
2-2.  CONFIRMATION AFTER UPGRADE
Procedure
1.  Insert the plug of the AC adaptor into DC IN 9V terminal on the 
back surface of the photo frame while pressing the [MENU] button 
and [ENTER] button to turn on the power.
2.  Release the [MENU] button and [ENTER] button when a “S-Frame” 
logo appears.
3.  After displaying an initial screen of the service mode, confirm the 
figure of “CHECKSUM” (hexadecimal number) is the same as the 
upgraded version of the firmware that has been described in the 
homepage of ESI. (Fig. 2-2-1)
4.  Turn off the power pressing the 1 (on/standby) button for about a 
second and unplug the AC adaptor.
2-1-3. WRITING OF FIRMWARE
Procedure
1.  Delete DPF_ALEX99.VUP from the SD card.
2.  Copy  all  files  and  folders  created  by  the  decompression  of 
SDUPDATER_2010XXXX.zip in the folder of SDUPDATER onto 
the root directory of the SD card. (most significant hierarchy)
Note:  Do not copy a whole SDUPDATER folder.
3.  Insert the SD card into the SD card slot on the back surface of the 
photo frame.
4.  Press the 1
 (on/standby)
 button to turn on the power.
Note:  Do not press the [VIEW MODE] button.
5.  When the maintenance mode screen appears, move the cursor to 
“Updated firmware” by pressing the [V] [v] button, and press the 
[ENTER] button. (Fig. 2-1-11)
6.  When a “Checking the update file.” appears, release the [ENTER] 
button. (Fig. 2-1-12)
5.  After returning to the initial screen of the service mode, confirm 
destination has changed.
6.  Turn off the power pressing the 1 (on/standby) button for about a 
second and unplug the AC adaptor.
4.  Move the cursor to the proper destination by pressing the [V] [v] [B] 
[b] buttons and press the [ENTER] button. (Fig. 2-3-2)
2-3.  CHANGE THE DESTINATION
Note: 
•  Execute  resetting  the  destination  even  if  the  proper  destination  is  al-
ready displayed in the initial screen of the service mode. (XX in “DPF-
XR100(XX)” is destination.) (Fig. 2-3-1)
•  Execute  “2-4.  INITIALIZATION  OF  SETTING”  after  changing  the 
destination.
Procedure
1.  Insert the plug of the AC adaptor into DC IN 9V terminal on the 
back surface of the photo frame while pressing the [MENU] button 
and [ENTER] button to turn on the power.
2.  Release the [MENU] button and [ENTER] button when a “S-Frame” 
logo appears.
3.  After displaying an initial screen of the service mode, move the 
cursor to “Select Model” by pressing the [V] [v] button, and press 
the [ENTER] button. (Fig. 2-3-1)
CEC Test
--
USB Test
A:-- B:--
????????
Card Test
--
Button Test
--
LCD Calibrate
Frame Angle : 0
CHECKSUM: XXXXXXXX (H)
DATE: SEP 9 2010 14:39:13
USB SERIAL NO: XXXXXXXX
DPF-XR100 (XX)
Fig. 2-2-1
Select Model
--
HDMI Test
CEC Test
--
USB Test
A:-- B:--
????????
Card Test
--
Frame Angle : 0
CHECKSUM: XXXXXXXX (H)
DATE: SEP 9 2010 14:39:13
USB SERIAL NO: XXXXXXXX
DPF-XR100 (XX)
Fig. 2-3-1
U2
E35
AU3
KR2
TW6
CN9
JE3
BR4
J1
***
Select Model
***
E33
E32
CEU
CEP
CED
CEK
CA2
Fig. 2-3-2
Maintenance mode
Update firmware
Initialize system
Fig. 2-1-11
Fig. 2-1-12
Checking the update file.
Insert the memory card and
press [ENTER].
Fig. 2-1-13
Current version :99.99
Updated version :1.00
Press [ENTER] to update
the firmware.
Fig. 2-1-14
Completed.
Restart the Digital Photo Frame.
CEC Test
--
USB Test
A:-- B:--
????????
Card Test
--
Button Test
--
LCD Calibrate
Frame Angle : 0
CHECKSUM: XXXXXXXX (H)
DATE: SEP 9 2010 14:39:13
USB SERIAL NO: XXXXXXXX
DPF-XR100 (XX)
Fig. 2-1-15
2-4.  INITIALIZATION OF SETTING
Various settings are returned to factory default by initializing the setting.
Execute this mode when returning the set to the customer.
However, the date setting is maintained.
Procedure
1.  Insert the plug of the AC adaptor into DC IN 9V terminal on the 
back surface of the photo frame while pressing the [MENU] button 
and [ENTER] button to turn on the power.
2.  Release the [MENU] button and [ENTER] button when a “S-Frame” 
logo appears.
3.  After displaying an initial screen of the service mode, move the 
cursor to “Set Default” by pressing the [V] [v] button, and press the 
[ENTER] button. (Fig. 2-4-1)
4.  Confirm “OK” appears at the right of “Set Default”.
5.  Turn off the power pressing the 1 (on/standby) button for about a 
second and unplug the AC adaptor.
Set Default
Select Test
HDMI Test
CEC Test
USB Test
Frame Angle : 0
CHECKSUM: XXXXXXXX (H)
DATE: SEP 9 2010 14:39:13
USB SERIAL NO: XXXXXXXX
DPF-XR100 (CA2)
A:-- B:--
????????
--
--
--
Fig. 2-4-1
7.  When the version up screen appears, confirm the figure of “Updated 
version” is the same as the version that has been described in the 
homepage of ESI, and press the [ENTER] button. (Fig. 2-1-13)
Page of 18
Display