Sony HDR-XR100 / HDR-XR100E / HDR-XR101 / HDR-XR105E / HDR-XR106E / HDR-XR200 / HDR-XR200E / HDR-XR200V / HDR-XR200VE (serv.man2) Service Manual ▷ View online

1-2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-XR100/XR100E/XR101/XR105E/XR106E/XR200/XR200E/XR200V/XR200VE_L2
1-3-3. Self-diagnosis Code Table
C
C
C
C
E
E
E
E
E
Block
Function
0
4
1
3
1
3
3
2
2
0
3
1
6
1
6
1
6
1
Detailed
Code
0
0
0
1
0
2
6
0
0
0
0
0
0
0
1
0
1
1
Symptom/State
Non-standard battery is used.
“Memory Stick Duo” is unformatted.
“Memory Stick Duo” is broken.
Access error
Difficult to adjust focus
(Cannot initialize focus)
Flash memory data are rewritten.
Drive fault
Difficult to adjust focus
(Cannot initialize focus.)
Zoom operations fault
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
initialization of the zoom lens occurred
simultaneously.
Self-diagnosis Code
Repaired b
y:
Note:
Start the Adjust Manual in the Adjust Station and refer to the “DESTINATON DATA WRITE”.
Correction
Use the InfoLITHIUM battery.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Remove the power source.
Reconnect it again and operate your camcorder again.
XR200/XR200E/XR200V/XR200VE:
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin eg, eh of
CN5101 on the LD-244 board). If it is OK, check the focus
motor drive IC (IC5506 on the LD-244 board).
Make flash memory data correct value. (Note)
Inspect or replacement of the hard disk drive.
XR100/XR100E/XR101/XR105E/XR106E:
Inspect the lens block focus reset sensor (pin 8 of CN5201 on
the LD-245 board) when focusing is performed when the focus
buttons of the touch panel are pressed in the focus manual mode,
and the focus motor driver circuit (IC5206 on the LD-245 board)
when focusing is not performed.
XR100/XR100E/XR101/XR105E/XR106E:
Inspect the lens block zoom reset sensor (pin q; of CN5201 on
the LD-245 board) when zooming is performed when the zoom
lever is operated, and the zoom motor drive circuit (IC5206 on
the LD-245 board) when zooming is not performed.
XR200/XR200E/XR200V/XR200VE:
Inspect the lens block zoom MR sensor (pin ea, ed of CN5101
on the LD-244 board) when zooming is performed when the
zoom lever is operated, and the zoom motor drive circuit
(IC5506 on the LD-244 board) when zooming is not performed.
XR100/XR100E/XR101/XR105E/XR106E:
Check whether the flexible board of the lens is broken, and
check whether it is inserted imperfectly. If there is no problem in
the flexible board, inspect the focus/zoom motor drive circuit
(IC5206 on the LD-245 board).
XR200/XR200E/XR200V/XR200VE:
Check both C : 32 : 60 and E : 61 : 10 of the self-diagnosis code.
1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-XR100/XR100E/XR101/XR105E/XR106E/XR200/XR200E/XR200V/XR200VE_L2
E
E
E
E
E
E
E
E
E
E
E
E
E
Block
Function
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
9
1
9
4
9
4
9
5
9
6
Detailed
Code
0
0
0
1
0
2
0
3
1
0
1
1
1
2
2
0
0
1
0
0
0
2
0
0
0
0
Symptom/State
Handshake correction function does not
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
work well. (With YAW angular velocity
sensor output stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure.
Shift lens overheating (Pitch)
Shift lens overheating (Yaw)
Abnormality of thermistor.
Abnormality when flash is being
charged.
Fault of writing or erasing the flash
memory
BGM data error
GPS hardware error
Map area mount error
Self-diagnosis Code
Repaired b
y:
Correction
XR100/XR100E/XR101/XR105E/XR106E:
Inspect PITCH angular velocity sensors (SE6502 on the FR-297
board) peripheral circuits.
XR200/XR200E/XR200V/XR200VE:
Inspect PITCH/YAW angular velocity sensors (SE6501 on the
FR-296 board) peripheral circuits.
XR100/XR100E/XR101/XR105E/XR106E:
Inspect YAW angular velocity sensors (SE6501 on the FR-297
board) peripheral circuits.
XR200/XR200E/XR200V/XR200VE:
Inspect PITCH/YAW angular velocity sensors (SE6501 on the
FR-296 board) peripheral circuits.
XR200/XR200E/XR200V/XR200VE:
Refer to [1-4-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
XR200/XR200E/XR200V/XR200VE:
Inspect the steadyshot circuit (IC5506 on the LD-244 board).
XR200/XR200E/XR200V/XR200VE:
Replacement of lens block. If an error occurs again, replace the
LD-244 board. (Note)
XR200/XR200E/XR200V/XR200VE:
Refer to [1-4-2. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
XR200/XR200E/XR200V/XR200VE:
Refer to [1-4-3. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
XR200/XR200E/XR200V/XR200VE:
IRefer to [1-4-4. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
XR200/XR200E/XR200V/XR200VE:
Checking of flash unit or replacement of flash unit.
Inspect the flash memory (IC2101 on the VC-548 board).
XR200/XR200E/XR200V/XR200VE:
Inspect the flash memory (IC2101 on the VC-548 board). If it is
OK, check the CPU (IC1701 on the VC-548 board).
XR200V/XR200VE:
Check whether the flexible board of the GPS module is broken,
and check whether it is inserted imperfectly. If there is no
problem the flexible board, inspect or replacement of the GPS
module.
XR200V/XR200VE:
Inspect or replacement of the hard disk drive.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-XR100/XR100E/XR101/XR105E/XR106E/XR200/XR200E/XR200V/XR200VE_L2
1-4. METHOD  OF  COPING  WITH  SHIFT  LENS  ERROR
(XR200/XR200E/XR200V/XR200VE)
R5620
IC5506
R5528
R5532
LD-244 BOARD (SIDE A)
about 330 msec
IC1301
VC-548 BOARD (SIDE A)
Note:
The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of R5620 on the LD-244 board
Fig. 1
Measurement points on the LD-244 board
Fig. 3
Measurement points on the VC-548 board
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5620 in the periphery of IC5506 on the LD-244 board, turn the
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
the camera control circuit (IC1301 of VC-548 board) periphery.
Note:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-4-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
1-5
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-XR100/XR100E/XR101/XR105E/XR106E/XR200/XR200E/XR200V/XR200VE_L2
Order
Block
Page Address Data
Procedure
1
11
80
7430
01
Write the data. (After it starts, set it before caution is displayed.)
2
11
8E
F654
01
Write the data.
3
11
8E
F655
F0
Write the data.
4
11
8E
F658
01
Write the data. (Note 1)
5
11
8E
F658
00
Write the data.
6
11
8E
F654
00
Write the data.
7
11
8E
F655
10
Write the data.
8
11
8E
F658
01
Write the data. (Note 1)
9
11
8E
F658
00
Write the data.
10
11
80
7430
00
Write the data.
11
Check if the shift lens moves while setting the order 2 to 9. If the shift lens does not move,
replace the lens block (Note 2). When the shift lens moved, proceed to the order 12.
12
While setting the order 2 to 9, measure with an oscilloscope the output voltage of R5532 in
the periphery of IC5506 on the LD-244 board to check the output voltage varies.
13
If the output voltage does not vary, replace the lens block (Note 2). When the output voltage
varied, proceed to the order 14.
14
Turn the power OFF.
15
While measuring with an oscilloscope the output voltage of R5620 in the periphery of
IC5506 on the LD-244 board, turn the power ON to check that the output voltage
immediately after the power on change as shown in Fig. 2.
16
If the output voltage change as shown in Fig. 2, replace the lens block (Note 2). If it does
not change as shown in Fig. 2, inspect the camera control circuit (IC1301 of VC-548 board)
periphery.
Note 1:
Finish this operation within 10 seconds. If it is likely to take more than 10 seconds, set block: 11, page: 8E, address: F658, data: 00, and then retry.
Note 2:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-4-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred
Connect by the SeusEX and perform the following process.
Page of 116
Display

Click on the first or last page to see other HDR-XR100 / HDR-XR100E / HDR-XR101 / HDR-XR105E / HDR-XR106E / HDR-XR200 / HDR-XR200E / HDR-XR200V / HDR-XR200VE (serv.man2) service manuals if exist.