Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc5-hdr-hc5e-hdr-hc7-hdr-hc7e-sm4.pdf
Date

Sony HDR-HC5 / HDR-HC5E / HDR-HC7 / HDR-HC7E (serv.man4) Service Manual ▷ View online

6-47
HDR-HC5/HC5E/HC7/HC7E_ADJ
1-3-4.
Initialization of 7C, 7E, 7F Page Data
1.
Initializing of 7C, 7E, 7F Page Data
Note 1:
If “Initialization of Pages 7C, 7E, 7F” is executed, all
data on pages 7C, 7E, 7F are initialized.
(Only an individual page cannot be initialized)
Note 2:
If the 7C, 7E, 7F page data has been initialized, the fol-
lowing adjustments need to be performed again.
1) Modification of 7C, 7E, 7F page data
2) HALL adjustment (1) (if all areas were initialized)
3) Angular velocity sensor sensitivity adjustment (if all
areas were initialized)
Adjustment Page
7C
Adjustment Address
00 to FF
Adjustment Page
7E
Adjustment Address
00 to FF
Adjustment Page
7F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
07
3
2
01
2D
Press PAUSE (Write) button.
(72)
4
2
02
Check the data changes to
(72)
“01”.
5
2
01
00
Press PAUSE (Write) button.
(72)
6
0
10
00
7
Perform “Modification of
7C, 7E, 7F Page Data”.
2.
Modification of 7C, 7E, 7F Page Data
If the 7C, 7E, 7F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 7C, 7E, 7F, set data: 01 to
page: 0, address: 10, and then select pages C, E, F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table. If different, change them to the adjustment
initial values.
Processing after Completing Modification Camera Control
Data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
6-48
HDR-HC5/HC5E/HC7/HC7E_ADJ
3.
7C Page table
Note 1:
If reading/writing data on pages 7C, set data: 07 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 7C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 7C, 7E, 7F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 7C, 7E, 7F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 11
Fixed data-1 (Initialized data)
12
13
14
Fixed data-2
15
16, 17
Fixed data-1 (Initialized data)
18
19
Fixed data-2
1A to FF
Fixed data-1 (Initialized data)
4.
7E Page table
Note 1:
If reading/writing data on pages 7E, set data: 07 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 7E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 7C, 7E, 7F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 7C, 7E, 7F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 16
Fixed data-1 (Initialized data)
17
Fixed data-2
18 to 1B
Fixed data-1 (Initialized data)
1C
1D
1E
Fixed data-2
1F
20 to 50
Fixed data-1 (Initialized data)
51
Fixed data-2
52
Fixed data-1 (Initialized data)
53
Fixed data-2
54 to AA
Fixed data-1 (Initialized data)
AB
Fixed data-2
AC, AD
Fixed data-1 (Initialized data)
AE
Fixed data-2
AF to C3
Fixed data-1 (Initialized data)
C4
C5
Fixed data-2
C6 to EF
Fixed data-1 (Initialized data)
F0
Fixed data-2
F1 to FF
Fixed data-1 (Initialized data)
Ver. 1.2  2008.06
6-49
HDR-HC5/HC5E/HC7/HC7E_ADJ
5.
7F Page table
Note 1:
If reading/writing data on pages 7F, set data: 07 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 7C, 7E, 7F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 7C, 7E, 7F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 03
Fixed data-1 (Initialized data)
04
80
80
05
80
80
06
80
80
07
80
80
08
03
03
09
77
77
0A
03
03
HALL adj. (1)
0B
79
79
0C
00
00
0D
A3
A3
0E
00
00
0F
83
83
10, 11
Fixed data-1 (Initialized data)
12
36
36
Angular velocity sensor sensitive
13
36
36
adj.
14 to FF
Fixed data-1 (Initialized data)
6-50
HDR-HC5/HC5E/HC7/HC7E_ADJ
1-4.
CAMERA  SYSTEM  ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except Origin Oscillation Check”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1.
Origin Oscillation Check (CM-076/077 board)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
Pin qj of CN6801 on CM-076 board
(HDR-HC5/HC5E)
Pin qh of CN6601 on CM-077 board
(HDR-HC7/HC7E)
Measuring Instrument
Frequency counter
Specified value
f = 40459550 
± 813 Hz (HDR-HC5)
f = 31185000 
± 626 Hz (HDR-HC5E)
f = 44505494 
± 895 Hz (HDR-HC7)
f = 37125000 
± 745 Hz (HDR-HC7E)
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Fig. 6-1-9
17
CN6801
CM-076 BOARD (SIDE B)
1
30
16
CN6601
1
40
CM-077 BOARD (SIDE B)
HDR-HC5/HC5E
HDR-HC7/HC7E
2.
HALL Adjustment (1) (HDR-HC7/HC7E)  
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the offset and gain to eliminate the output dispersion of the
Hall sensor.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
7F
Adjustment Address
04 to 0F
Specified value
Data of page: 72 address: 03 is “00”
Data of page: 72 address: 04 is “00”
Note 1:
If reading/writing data on pages 72, 7F set data: 07 to
page: 0, address: 10, and then select pages: 2, F. By this
data setting, the pages 72, 7F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Perform this adjustment only when replacing the lens
block. When the microprocessor, circuit etc. is damaged,
don't perform this adjustment but check the steady shot
operations only.
Note 3:
Perform the adjustment with the camcorder in horizontal
state.
Note 4:
Do not move the set.
Switch setting
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
07
2
Press PAUSE (Write) button.
3
(72)
01
97
(Note 5)
2
Check the data changes to
4
(72)
02
“01”.
2
Check the data is “00”.
5
(72)
03
(Note 6)
6
2
Check the data is “00”.
(72)
04
(Note 6).
Note 5:
The adjustment data will be automatically input to page:
7F, address: 04 to 07.
Note 6:
If the data is other than “00”, perform readjustment.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
2
1
(72)
01
00
Press PAUSE (Write) button.
2
0
10
00
3
0
01
00
4
Turn off the power and turn
on again.
5
Shake the camcorder
vertically and horizontally to
check that the steady shot
function operates normally.
Page of 126