DOWNLOAD Sony HDR-FX7 / HDR-FX7E (serv.man5) Service Manual ↓ Size: 1.13 MB | Pages: 117 in PDF or view online for FREE

Model
HDR-FX7 HDR-FX7E (serv.man5)
Pages
117
Size
1.13 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx7-hdr-fx7e-sm5.pdf
Date

Sony HDR-FX7 / HDR-FX7E (serv.man5) Service Manual ▷ View online

6-107
HDR-FX7/FX7E_ADJ
11. Switch Check (2)
Page 7
Address 63 to 6B
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) Select page: 7, address: 63 to 6B.
2) By discriminating the display data, the pressed key can be discriminated.
Address
63
(KEY AD7)
(IC3601 <zcm )
64
(KEY AD8)
(IC3601 <zc, )
65
(KEY AD0)
(IC3601 <zc. )
66
(KEY AD1)
(IC3601 <zv/
 
)
67
(KEY AD2)
(IC3601 <zvz
 
)
68
(KEY AD3)
(IC3601 <zvx
 
)
69
(KEY AD4)
(IC3601 <zvc )
6A
(KEY AD5)
(IC3601 <zvv )
6B
(KEY AD6)
(IC3601 <zvb )
00 to 0C
ASSIGN
1
(CK18500 block)
(S3001)
PICTURE
PROFILE
(CF18500 block)
(S4005)
REC
START/STOP
(PS18500 block)
(S1001)
STOP
(RR-003)
(S9603)
REC
START/STOP
(FP-483 flexible)
FOCUS
(CK18500 block)
(S3005)
SEL/
PUSH EXEC
(CF 18500 block)
(S4008)
0D to 27
ASSIGN
2
(CK18500 block)
(S3002)
STATUS
CHECK
(CF18500 block)
(S4004)
REW
(RR-003)
(S9606)
ZOOM
WIDE
(FP-483 flexible)
EXPANDED
FOCUS
(CK18500 block)
(S3007)
MENU
(CF 18500 block)
(S4007)
32 to 3A
ASSIGN
3
(CK18500 block)
(S3003)
ASSIGN
4
(RR-003)
(S9608)
REC
(RR-003)
(S9609, S9611)
ZOOM
TELE
(FP-483 flexible)
PAUSE
(RR-003)
(S9604)
GAIN
(CF 18500 block)
(S4002)
4F to 58
PUSH
AUTO FOCUS
(CK18500 block)
(S3004)
ASSIGN
5
(RR-003)
(S9610)
PLAY
(RR-003)
(S9613)
SHUTTER
SPEED
(CF 18500 block)
(S4003)
73 to 7B
EXPOSURE
IRIS
(CK18500 block)
(S3006)
ASSIGN
6
(RR-003)
(S9612)
FF
(RR-003)
(S9615)
WHT BAL
(CF 18500 block)
(S4006)
8B to B7
ZEBRA
OFF
(RR-003)
(S9614)
SLOW
(RR-003)
(S9616)
ZOOM
OFF
(FP-483 flexible)
(S303)
AUTO LOCK
HOLD
(CF 18500 block)
(S4001)
B8 to E6
ZEBRA
100
(RR-003)
(S9614)
ZOOM
H
(FP-483 flexible)
(S303)
PANEL
REVERSE
(FP-487 flexible)
(S701)
AUTO LOCK
LOCK
(CF 18500 block)
(S4001)
PANEL
CLOSE
(FP-487 flexible)
(S702)
E7 to FF
No key input
ZEBRA
70
(RR-003)
(S9614)
No key input
No key input
ZOOM
L
(FP-483 flexible)
(S303)
No key input
PANEL
NORMAL
(FP-487 flexible)
(S701)
AUTO LOCK
MANUAL
(CF 18500 block)
(S4001)
PANEL
OPEN
(FP-487 flexible)
(S702)
Data
PHOTO/
EXPANDED
FOCUS
(PL18500 block)
(S2001)
VOLUME/
MEMORY
+
(RR-003)
(S9605)
VOLUME/
MEMORY
(RR-003)
(S9607)
6-108
HDR-FX7/FX7E_ADJ
12. LED Check
Page 7
Address 00, 01 and 04
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method:
Order Page Address Data
Procedure
1
Set the unit to CAMERA-
TAPE mode.
2
7
01
90
3
7
04
01
4
7
00
01
Press PAUSE (Write) button.
5
7
02
Check the data changes to
“01”.
6
Check that the following
LED are lit.
• REC LAMP
• CHARGE
• MS ACCESS
7
7
01
90
8
7
04
00
9
7
00
01
Press PAUSE (Write) button.
10
7
00
00
11
7
01
00
12
7
02
Check the data changes to
“01”.
13. Record of Use Check (1)
Page 7
Address A4 to AF
Note 1:
This data will not be erased (reset) when the lithium 3 V
power supply (RR-003 board BT9601) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: A4 to
AF.
Address
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
Function
Power supplying
Hour (H)
time
Hour (M)
Hour (L)
(BCD code)
Minute
Drum rotation
Hour (H)
counted time
Hour (M)
Hour (L)
(BCD code)
Minute
Tape run time
Hour (H)
Hour (M)
Hour (L)
(BCD code)
Minute
Remarks
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
6-109
HDR-FX7/FX7E_ADJ
14. Record of Use Check (2)
Page 7
Address 90 to 95
Note 1:
This data will not be erased (reset) when the lithium 3 V
power supply (RR-003 board BT9601) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: 90 to
95.
Initializing method:
Order Page Address Data
Procedure
1
7
90
00
Press PAUSE (Write) button.
2
7
91
00
Press PAUSE (Write) button.
3
7
92
00
Press PAUSE (Write) button.
4
7
93
00
Press PAUSE (Write) button.
5
7
94
00
Press PAUSE (Write) button.
6
7
95
00
Press PAUSE (Write) button.
Address
90
91
92
93
94
95
Initializing method:
Order Page Address Data
Procedure
1
7
A4
00
Press PAUSE (Write) button.
2
7
A5
00
Press PAUSE (Write) button.
3
7
A6
00
Press PAUSE (Write) button.
4
7
A7
00
Press PAUSE (Write) button.
5
7
A8
00
Press PAUSE (Write) button.
6
7
A9
00
Press PAUSE (Write) button.
7
7
AA
00
Press PAUSE (Write) button.
8
7
AB
00
Press PAUSE (Write) button.
9
7
AC
00
Press PAUSE (Write) button.
10
7
AD
00
Press PAUSE (Write) button.
11
7
AE
00
Press PAUSE (Write) button.
12
7
AF
00
Press PAUSE (Write) button.
Function
Eject count with tape
Count (H)
Count (M)
(BCD code)
Count (L)
Eject count without
Count (H)
 tape
Count (M)
(BCD code)
Count (L)
Remarks
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
100000th place digit and 10000th place digit of Eject count (decimal digit)
1000th place digit and 100th place digit of Eject count (decimal digit)
10th place digit and 1st place digit of Eject count (decimal digit)
6-110
HDR-FX7/FX7E_ADJ
15. Record of Use Check (3)
Page 7
Address C8 to CD
Note 1:
 This data will not be erased (reset) when the lithium 3 V
power supply (RR-003 board BT9601) is removed.
Note 2:
Check that the data of page: 0, address 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: C8 to
CD.
16. Record of Self-diagnosis Check
Page 7
Address B0 to C6
Note 1:
 This data will not be erased (reset) when the lithium 3 V
power supply (RR-003 board BT9601) is removed.
Note 2:
Check that the data of page: 0, address 10 is “00”.
*1 : “01” 
t “C”, “03” t “E”
Using method:
1) The past self-diagnosis codes are displayed at page: 7, address:
BC to C6. Refer to “1-5. SELF-DIAGNOSIS FUNCTION” of
“SERVICE MANUAL, LEVEL 2” for detail of the self-diag-
nosis code.
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
Address
B0
B1
B2
B4
B5
B6
B8
B9
BA
BC
BD
BE
C0
C1
C2
C4
C5
C6
Self-diagnosis code
“Repaired by” code (Occurred 1st time)   *1
“Block function” code (Occurred 1st time)
“Detailed” code (Occurred 1st time)
“Repaired by” code (Occurred 2nd time)   *1
“Block function” code (Occurred 2nd time)
“Detailed” code (Occurred 2nd time)
“Repaired by” code (Occurred 3rd time)   *1
“Block function” code (Occurred 3rd time)
“Detailed” code (Occurred 3rd time)
“Repaired by” code (Occurred 4th time)   *1
“Block function” code (Occurred 4th time)
“Detailed” code (Occurred 4th time)
“Repaired by” code (Occurred 5th time)   *1
“Block function” code (Occurred 5th time)
“Detailed” code (Occurred 5th time)
“Repaired by” code (Occurred the last time)   *1
“Block function” code (Occurred the last time)
“Detailed” code (Occurred the last time)
Initializing method:
Order Page Address Data
Procedure
1
7
01
C0
2
7
00
01
Press PAUSE button.
3
7
B0 to C6
Check that the data is “00”.
4
7
00
00
5
7
01
00
Ver. 1.1  2007.05
Page of 117
Display