Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx7-hdr-fx7e-sm4.pdf
Date

Sony HDR-FX7 / HDR-FX7E (serv.man4) Service Manual ▷ View online

6-95
HDR-FX7/FX7E_ADJ
H
A
C
B
Fig. 6-3-8
4.
COMPONENT OUT Pb Level Adjustment
(TT-003 board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pb signal terminal of COMPONENT
OUT jack (75 
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
94
Specified value
Pb level: A = 525 
±
 10 mVp-p
Sync level: B = C = 300 
±
 10 mVp-p
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
71
01
Press PAUSE (Write) button.
3
0
10
01
4
8
00
Set the bit value of bit7 is
“1”, and press PAUSE
(18)
(Write) button. (Note)
5
0
10
00
6
C
94
Change the data and set the
Pb signal level (A) to the
specified value.
7
C
94
Press PAUSE (Write) button.
8
Check the sync signal (B, C)
to the specified value.
9
0
10
01
10
8
00
Set the bit value of bit7 is
“0”, and press PAUSE
(18)
(Write) button. (Note)
11
0
10
00
12
3
70
10
Press PAUSE (Write) button.
13
3
70
Check the data changes to
“11”.
14
0
01
00
Note:
For the bit values, refer to “6-4. SERVICE MODE”, “4-4.
3. Bit value discrimination”.
6-96
HDR-FX7/FX7E_ADJ
3-5.
AUDIO SYSTEM ADJUSTMENTS
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to
the video system measuring instruments as shown in Fig. 6-3-9.
Fig. 6-3-9
47 k 
47 k 
: 1-249-437-11
TV monitor
A/V jack
Video
Audio (L)
Audio (R)
Audio level meter 
In Playback
Main unit
1.
Playback Level Check
Mode
VTR playback (VCR mode)
Signal
Alignment tape:
For audio operation check
(XH5-3 (NTSC))
(XH5-3P (PAL))
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Audio level meter and frequency
counter
Specified Value
32 kHz mode: 1 kHz, + 3.0 
±
 2.0 dBs
48 kHz mode: 1 kHz, + 3.0 
±
 2.0 dBs
44.1 kHz mode:
The 7.35 kHz signal level during EMP
OFF is +2.0 
±
 2.0 dBs.
The 7.35 kHz signal level during EMP
ON is 
±
 2 dB from the signal level
during EMP OFF.
Checking Method:
1) Check that the playback signal level is the specified value.
6-97
HDR-FX7/FX7E_ADJ
6-4. SERVICE MODE
4-1.
ADJUSTMENT REMOTE COMMANDER
(RM-95)
The adjustment remote commander (RM-95) is used for changing
the calculation coefficient in signal processing, EVR data, etc. The
adjustment remote commander (RM-95) performs bi-directional
communication with the unit using the remote commander signal
line (LANC). The resultant data of this bi-directional communica-
tion is written in the non-volatile memory.
1.
Using the Adjustment Remote Commander (RM-95)
1) Connect the adjustment remote commander to the LANC ter-
minal.
2) Set the HOLD switch of the adjustment remote commander
(RM-95) to “HOLD” (SERVICE position). If it has been prop-
erly connected, the LCD on the adjustment remote commander
(RM-95) will display as shown in Fig. 6-4-1.
Fig. 6-4-1
3) Operate the adjustment remote commander (RM-95) as fol-
lows.
Changing the page
The page increases when the EDIT SEARCH+ button is
pressed, and decreases when the EDIT SEARCH
 button is
pressed. There are altogether 16 pages, from 0 to F.
Changing the address
The address increases when the FF (M) button is pressed,
and decreases when the REW (m) button is pressed. There
are altogether 256 addresses, from 00 to FF.
Changing the data (Data setting)
The data increases when the PLAY (N) button is pressed,
and decreases when the STOP (x) button is pressed. There
are altogether 256 data, from 00 to FF.
Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data in the nonvolatile memory. (The new adjusting data will
not be recorded in the nonvolatile memory if this step is not
performed)
4) After completing all adjustments, turn off the main power sup-
ply (8.4 V) once.
Page
Data
Address
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 1112 13 14 15
2.
Precautions Upon Using the Adjustment Remote
Commander (RM-95)
Mishandling of the adjustment remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjust-
ments and new adjustment data after each adjustment.
6-98
HDR-FX7/FX7E_ADJ
4-2.
ADJUSTMENT REMOTE COMMANDER
 (NEW LANC JIG)
The adjustment remote commander (New LANC Jig) is used for
changing the calculation coefficient in signal processing, EVR data,
etc. The adjustment remote commander (New LANC Jig) performs
bi-directional communication with the unit using the remote com-
mander signal line (LANC). The resultant data of this bi-direc-
tional communication is written in the non-volatile memory.
1.
Using the Adjustment Remote Commander
(New LANC Jig))
1) Connect the adjustment remote commander (New LANC Jig)
to the LANC terminal via the LANC cable (J-6082-442-A).
2) Set the slide switch of the adjustment remote commander (New
LANC Jig) to “SERVICE” (SERVICE position). If it has been
properly connected, the LCD on the adjustment remote com-
mander (New LANC Jig) will display as shown in Fig. 6-4-2.
Fig. 6-4-2
3) Operate the adjustment remote commander (New LANC Jig)
as follows.
Changing the page
The page increases when the Page+ (M) button is pressed,
and decreases when the Page
 (m) button is pressed.
Changing the address
The address increases when the ADD+ (N) button is
pressed, and decreases when the ADD
  (X) button is
pressed. There are altogether 256 addresses, from 00 to FF.
Changing the data (Data setting)
The data increases when the Data+ button is pressed, and
decreases when the Data
 button is pressed. There are alto-
gether 256 data, from 00 to FF.
Writing the adjustment data
The Write (x) button must be pressed to write the adjust-
ment data in the nonvolatile memory. (The new adjusting
data will not be recorded in the nonvolatile memory if this
step is not performed)
4) After completing all adjustments, turn off the main power sup-
ply (8.4 V) once.
2.
Precautions Upon Using the Adjustment Remote
Commander (New LANC Jig)
Mishandling of the adjustment remote commander (New LANC
Jig) may erase the correct adjustment data at times. To prevent
this, it is recommended that all adjustment data be noted down
before beginning adjustments and new adjustment data after each
adjustment.
Page
Address
Data