HDR-FX7/FX7E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
64
04
3
0
10
0A
E
4
(AE)
8C
01
Press PAUSE (Write) button.
5
0
10
00
6
6
01
13
Press PAUSE (Write) button.
7
Wait for 2 seconds.
8
6
01
27
Press PAUSE (Write) button.
(Note 9)
9
6
02
Check the data changes to “01”.
10
6
0C
Check the data is “00”.
11
0
10
06
F
12
(6F)
2F
Check the data is “00” to “0E”.
13
0
10
00
Note 9:
The adjustment data will be automatically input to page:
6F, address: 11, 20 to 3F, 4C, 4D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to “01”.
4
6
01
00
Press PAUSE (Write) button.
5
6
64
00
6
0
10
0A
E
7
(AE)
8C
00
Press PAUSE (Write) button.
8
0
10
00
9
0
01
00
10
Perform “Flange Back
Check”.
6-36
HDR-FX7/FX7E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
64
04
3
0
10
0A
E
4
(AE)
8C
01
Press PAUSE (Write) button.
5
0
10
00
6
6
01
13
Press PAUSE (Write) button.
7
Wait for 2 seconds.
8
6
01
15
Press PAUSE (Write) button.
(Note 7)
9
6
02
Check the data changes to
“01”.
10
6
0C
Check the data is “00”.
11
0
10
06
12
F
2F
Check the data is “00” to
(6F)
“0E”.
13
0
10
00
Note 7:
The adjustment data will be automatically input to page:
6F, address: 11, 20 to 3F, 4C, 4D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to “01”.
4
6
01
00
Press PAUSE (Write) button.
5
6
64
00
6
0
10
0A
E
7
(AE)
8C
00
Press PAUSE (Write) button.
8
0
10
00
9
0
01
00
10
Perform “Flange Back
Adjustment (2)”.
7.
Flange Back Adjustment
(Using the flange back adjustment chart and
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
7-1. Flange Back Adjustment (1) 
RadarW
RadarW
RadarW
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
11, 20 to 3F, 4C, 4D
Specified value
Data of page: 6F, address: 2F is
“00” to “0E”
Data of pege: 6, address: 0C is “00”
Note 1:
Perform “HALL Adjustment”, “MR Adjustment” and
“Differential Gain Adjustment” before this adjustment.
Note 2:
Perform the adjustment with the lens in horizontal state.
Note 3:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5:
Don't touch the zoom lever during adjustment.
Note 6:
After adjustment, if the focusing to a subject located at
infinity failed, increase the illuminance of the chart and
perform readjustment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
6-37
HDR-FX7/FX7E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
64
04
3
0
10
0A
E
4
(AE)
8C
01
Press PAUSE (Write) button.
5
0
10
00
6
6
01
13
Press PAUSE (Write) button.
7
Wait for 2 seconds.
8
Place ND filter on the lens so
that the optimum image is
obtain.
9
6
01
29
Press PAUSE (Write) button.
(Note 5)
10
6
02
Check the data changes to “01”.
11
6
0C
Check the data is “00”.
12
0
10
06
13
F
2F
Check the data is “00” to “0E”.
(6F)
14
0
10
00
Note 5:
The adjustment data will be automatically input to page:
6F, address: 11, 20 to 3F, 4C, 4D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to “01”.
4
6
01
00
Press PAUSE (Write) button.
5
6
64
00
6
0
10
0A
E
7
(AE)
8C
00
Press PAUSE (Write) button.
8
0
10
00
9
0
01
00
10
Perform “Flange Back
Check”.
7-2. Flange Back Adjustment (2) 
RadarW
RadarW
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
11, 20 to 3F, 4C, 4D
Specified value
Data of page: 6F, address: 2F is“00” to “0E”
Data of page: 6, address: 0C is“00”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4:
Don’t touch the zoom lever during adjustment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
6-38
HDR-FX7/FX7E_ADJ
9.
Flange Back Check (Using the Siemens star)
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Note 2:
When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Preparations before adjustments:
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
6
4D
40
4
Shoot the Siemens star with
the zoom TELE end.
5
Turn on the auto focus.
6
0
03
0F
7
1
Check that the lens is
focused. (Note 2)
8
6
21
10
9
Shoot the Siemens star with
the zoom WIDE end.
10
Observe the TV monitor and
check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
6
4D
40
5
0
03
00
8.
Flange Back Check
(Using the flange back adjustment jig)
Subject
Flange back adjustment jig
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) To open the IRIS, decrease the luminous intensity to the chart
of the flange back adjustment jig up to a point before noise
appear on the image. (approx. 200 lux)
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
6
4D
40
4
Shoot the chart with the
zoom TELE end.
5
6
2C
02
6
Check that the lens is
focused.
7
Shoot the chart with the
zoom WIDE end.
8
Check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
6
40
00
3
6
41
00
4
6
4D
00
Page of 113