1-5. SELF-DIAGNOSIS  FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder or LCD
screen what to do.
Details of the self-diagnosis functions are provided in the Instruction
manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
viewfinder or LCD screen shows a 4-digit display consisting of an
alphabet and numbers, which blinks at 3.2 Hz. This 5-character
display indicates the “repaired by:”, “block” in which the problem
occurred, and “detailed code” of the problem.
1 1
3 1
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
1-4. USING  SERVICE  JIG
Connect the CPC-7 jig connector (J-6082-382-A) to the CN1014 on the TT-003 board.
TT-003 BOARD
(SIDE B)
CN1014
1
1
16
16
8
9
CPC-7
(J-6082-382-A)
1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-FX7/FX7E_L2
1-5-3. Self-diagnosis Code Table
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Block
Function
0
4
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Detailed
Code
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
3
0
3
1
4
0
4
1
4
2
4
3
4
4
1
0
1
1
2
0
2
1
2
2
2
3
3
0
3
1
4
0
4
1
4
2
4
3
4
4
6
0
Symptom/State
Non-standard battery is used.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
S reel side tape slacking when unloading.
T reel fault.
S reel fault.
FG fault when starting capstan.
FG fault during normal capstan operations.
FG fault when starting drum.
PG fault when starting drum.
FG fault during normal drum operations.
PG fault during normal drum operations.
Phase fault during normal drum operations.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
S reel side tape slacking when
unloading.
T reel fault.
S reel fault.
FG fault when starting capstan.
FG fault during normal capstan
operations.
FG fault when starting drum.
PG fault when starting drum.
FG fault during normal drum
operations.
PG fault during normal drum
operations.
Phase fault during normal drum
operations.
Difficult to adjust focus
(Cannot initialize focus.)
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
If it does not recover, inspect the focus MR sensor of lens block
(Pin wl, ea of CN5802 on the YY-003 board).
If not faulty, inspect the focus motor drive circuit
(IC6004 on the YY-003 board).
1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-FX7/FX7E_L2
E
E
E
E
E
E
E
E
E
Block
Function
6
1
6
1
6
2
6
2
6
2
6
2
6
2
6
2
6
2
Detailed
Code
1
0
1
1
0
0
0
1
0
2
0
3
1
0
1
1
1
2
Symptom/State
Zoom operations fault
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur simulta-
neously.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure
Shift lens overheating (Pitch)
Shift lens overheating (Yaw)
Self-diagnosis Code
Repaired b
y:
Correction
Inspect the zoom MR sensor of lens block (Pin ed, eg of CN5802
on the YY-003 board) when zooming is performed when the zoom
switch is operated and the zoom motor drive circuit (IC6004 on
the YY-003 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect pitch angular velocity sensor (SE8001 on the JJ-004
board) peripheral circuits.
Inspect yaw angular velocity sensor (SE8002 on the JJ-004
board) peripheral circuits.
Refer to [1-6-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC6203 on the YY-003 board).
Refer to [1-6-2. E : 62 : 10 (Shift Lens Initializing Failure)
Occurred].
Refer to [1-6-3. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-6-4. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
1-6. METHOD OF COPING WITH SHIFT LENS ERROR
about 330 msec
Fig. 1
Measurement points on the YY-003 board
IC6203
R6233
R6242
R6244
YY-003 BOARD (SIDE A)
Fig. 2
Change in output voltage of R6233
Note: The length of low section will vary a little depending on the
conditions.
1-5
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-FX7/FX7E_L2
1-6-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
1-6-2. E : 62 : 10 [Shift Lens Initializing Failure] Occurred
Connect the adjustment remote commander (RM-95 or NEW LANC JIG) and perform the following process.
Order Page Address Data
Procedure
1
0
01
01
2
0
10
07
3
F
04
Read the data value and assume it as D
04
.
(7F)
4
F
04
Change the data and check that it has been changed. If no value changes or if value is 00 or FF, inspect
(7F)
the EEPROM (IC4202 of TT-003 board). If value changes, proceed to the order 5.
5
F
04
D
04
Press PAUSE (Write) button.
(7F)
6
F
05
Read the data value and assume it as D
05
.
(7F)
7
F
05
Change the data and check that it has been changed. If no value changes or if value is 00 or FF, inspect
(7F)
the EEPROM (IC4202 of TT-003 board). If value changes, proceed to the order 8.
8
F
05
D
05
Press PAUSE (Write) button.
(7F)
9
0
10
00
10
0
01
00
11
Perform “PSD Sensor Gradient Adjustment”. (Note 1)
12
Turn the power OFF and ON again.
13
Check that no error occurs. If an error occurs, replace the lens block (Note 2).
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R6233 in the periphery of IC6203 on the YY-003 board, turn the
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
the camera control circuit (IC4201 of TT-003 board) periphery.
Note: When the lens block was replaced, execute a necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
Note 1: Perform adjustment by referring to “SD Sensor Gradient Adjustment” in Service Manual, ADJ. After the adjustment, be
sure to perform “Optical Axis Adjustment” and “Angular Velocity Sensor Sensitivity Adjustment”.
Note 2: When the lens block was replaced, execute a necessary adjustment items referring to Service Manual, ADJ.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
Page of 117
Display

Click on the first or last page to see other HDR-FX7 / HDR-FX7E (serv.man2) service manuals if exist.