Movie / SECTION 6 ADJUSTMENTS
File
hdr-fx1-hdr-fx1e-sm3.pdf
Date

Sony HDR-FX1 / HDR-FX1E (serv.man3) Service Manual ▷ View online

6-74
HDR-FX1/FX1E
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
B
Example: If “8E” is displayed on the adjustment remote commander, the
bit values for bit7 to bit4 are shown in the A column, and the
bit values for bit3 to bit0 are shown in the B column.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
3. Bit value discrimination
Bit values must be discriminated using the display data of the
adjustment remote commander for following items. Use the table
below to discriminate if the bit value is “1” or “0”.
4. Switch check (1)
Page 2
Address 81
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 2, address: 81.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
5. Switch check (2)
Page 7
Address 4F
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 4F.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
6. Switch check (3)
Page 7
Address F3
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: F3.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
A
Bit
0
1
3
4
5
Function
POWER SW (XVTR ON SW) (PS5610 block S101)
POWER SW (XCAM ON SW) (PS5610 block S102)
EJECT SW (XEJECT SW) (FP-965 flexible S650)
CC DOWN SW (Mechanism chassis)
DISPLAY/BATTERY INFO SW (XBATT INFO SW)
(FK-090 block S602)
When bit value=1
VCR
CAMERA
ON
ON (DOWN)
ON
When bit value=0
OFF
OFF
OFF
OFF (UP)
OFF
Bit
4
Function
REC PROOF SW (Mechanism chassis)
When bit value=1
SAVE
When bit value=0
REC
Bit
2
3
Function
S jack (JK-274 board J102)
AUDIO/VIDEO jack (JK-274 board J103)
When bit value=1
Used
Used
When bit value=0
Not used
Not used
6-75
HDR-FX1/FX1E
Address
60 (Upper digits)
61 (Lower digits)
(KEY AD0)
(IC8009 <zc. )
62 (Upper digits)
63 (Lower digits)
(KEY AD1)
(IC8009 <zv/ )
64 (Upper digits)
65 (Lower digits)
(KEY AD2)
(IC8009 <zvz )
66 (Upper digits)
67 (Lower digits)
(KEY AD3)
(IC8009 <zvx )
68 (Upper digits)
69 (Lower digits)
(KEY AD4)
(IC8009 <zvc )
6A (Upper digits)
6B (Lower digits)
(KEY AD5)
(IC8009 <zvv )
6C (Upper digits)
6D (Lower digits)
(KEY AD6)
(IC8009 <zvb )
5C (Upper digits)
5D (Lower digits)
(KEY AD7)
(IC8009 <zcm )
5E (Upper digits)
5F (Lower digits)
(KEY AD8)
(IC8009 <zc, )
03FC
(03A0 to 03FF)
PANEL
OPEN
(FP-967 flexible)
(IC670, 671)
PANEL
NORMAL
(SW-433 board)
(S801)
LCD BACK
LIGHT OFF
(FK-090 board)
(S019)
No key input
ZEBRA/
PEAKING OFF
(MK-017 board)
(S105)
FOCUS
MANUAL
(CK-143 board)
(S206)
GAIN M
(FP-963
flexible)
(S631)
AUTO LOCK
MANUAL
(FP-966 flexible)
(S664)
WHT
A
(FP-963 flexible)
(S630)
7. Switch check (4)
Page 7
Address F5
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: F5.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
8. Switch check (5)
Page 7
Address 5C to 5F, 60 to 6D
Note: The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 5C to 5F, 60 to 6D.
2)
By discriminating the display data, the pressed key can be discriminated.
Example: If the data of address: 60 is “00” and .the data of address: 61 is “09”, the data of KEY AD0 signal is “0009”. It can be
discriminated that the STOP button is pressed.
Bit
0
1
2
Function
COMPONENT OUT connector (JK-274 board CN101)
MIC/LINE jack (JK-274 board J101)
Headphone jack (PS5610 block J102)
When bit value=1
Used
Used
Used
When bit value=0
Not used
Not used
Not used
033C
(02E2 to 039F)
PANEL
CLOSE
(FP-967 flexible)
(IC670, 671)
PANEL
REVERSE
(SW-433 board)
(S801)
LCD BACK
LIGHT ON
(FK-090 board)
(S019)
PEAKING
ON
(MK-017 board)
(S105)
FOCUS
AUTO/PUSH AUTO
(CK-143 board)
(S206, 205)
GAIN H
(FP-963
flexible)
(S631)
AUTO LOCK
HOLD
(FP-966 flexible)
(S664)
WHT
PRESET
(FP-963 flexible)
(S630)
0280
(0231 to 02E1)
SLOW
(FK-090
board)
(S012)
PAUSE
(FK-090
board)
(S003)
BARS
(FK-090
board)
(S015)
ZEBRA ON
(MK-017
board)
(S105)
FOCUS
INFINITY
(CK-143 board)
(S206)
GAIN L
(FP-963
flexible)
(S631)
AUTO LOCK
AUTO
(FP-966 flexible)
(S664)
WHT
B
(FP-963 flexible)
(S630)
01DC
(0197 to 0230)
FF
(FK-090
board)
(S004)
END
SEARCH
(FK-090 board)
(S016)
STATUS
CHECK
(MK-017 board)
(S102)
AUTO WHT
BAL
(CK-143 board)
(S204)
WHT BAL
(FP-966
flexible)
(S663)
REC
REVIEW
(FP-961 flexible)
(S610)
014C
(0114 to 0196)
PLAY
(FK-090
board)
(S007)
LCD BRIGHT-
(FK-090
board)
(S013)
DATA CODE
(FK-090
board)
(S022)
MENU
(MK-017
board)
(S108)
ASSIGN 3
(CK-143
board)
(S203)
SHUTTER
SPEED
(FP-966 flexible)
(S662)
SPOT LIGHT
(FP-961
flexible)
(S614)
00D8
(00A3 to 0113)
REC
(FK-090
board)
(S005, 018)
LCD BRIGHT +
(FK-090
board)
(S014)
ZERO SET
MEMORY
(FK-090 board)
(S001)
REC START/
STOP
(ZS-5610 block)
(S003)
P-MENU
(MK-017
board)
(S109)
ASSIGN 2
(CK-143
board)
(S202)
SHOT
TRANS B
(FP-961
flexible)
(S615)
GAIN
(FP-966
flexible)
(S661)
BACK LIGHT
(FP-961
flexible)
(S612)
006C
(0036 to 00A2)
REW
(FK-090
board)
(S021)
VOLUME -
(FK-090
board)
(S011)
START/STOP
(PS5610
block)
(S103)
PICTURE
PROFILE
(MK-017 board)
(S107)
ASSIGN 1
(CK-143
board)
(S201)
SHOT
TRANS A
(FP-961
flexible)
(S613)
IRIS
(FP-966
flexible)
(S660)
0000
(0000 to 0035)
STOP
(FK-090
board)
(S009)
VOLUME +
(FK-090
board)
(S010)
EXPAND
FOCUS
(CF5610 block)
(S001)
EXEC
(SELECT
DIAL UNIT)
SHOT TRANS
(STORE/CHECK/
EXEC)
(FP-961 flexible)
(S611)
Data (4 digits)
6-76
HDR-FX1/FX1E
9. LED check
Page 7
Address 00, 01, 04
Note: The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER .................................................................. CAMERA
Using method:
1)
Select page: 7, address: 01, and set data: 90.
2)
Select page: 7, address: 04, and set data: 01.
3)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
4)
Check that the following LEDs are lit.
FRONT TALLY, REAR TALLY, iLINK HDV, iLINK DV, Mode HDV, Mode DV, SHOT TRANSITION STORE, SHOT TRANSITION
CHECK, SHOT TRANSITION EXEC, CHARGE
5)
Select page: 7, address: 01, and set data: 90.
6)
Select page: 7, address: 04, and set data: 00.
7)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
8)
Select page: 7, address: 00, and set data: 00.
9)
Select page: 7, address: 01, and set data: 00.
10. Record of Use check (1)
Page 7
Address A7 to A9
Note1: When replacing the drum assembly or the mechanism deck, initialize the data of address: A7 to A9.
Note2: This data will be kept even if the lithium battery (FP-959 flexible BT591) is removed.
Note3: The data of page: 0, address: 10 must be “00”.
Using method:
1)
The record of use data is displayed at addresses: A7 to A9.
Initializing method:
1)
Select page: 7, address: A7, set data: 00 and press the PAUSE button.
2)
Select page: 7, address: A8, set data: 00 and press the PAUSE button.
3)
Select page: 7, address: A9, set data: 00 and press the PAUSE button.
11. Record of Use check (2)
Page 7
Address C8 to CD
Note1: This data will be kept even if the lithium battery (FP-959 flexible BT591) is removed.
Note2: The data of page: 0, address: 10 must be “00”.
Using method:
1)
The record of use data is displayed at addresses: C8 to CD.
Address
A7
A8
A9
Function
Drum rotation
Hour (H)
counted time
Hour (M)
(BCD code)
Hour (L)
Remarks
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence data
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
6-77
HDR-FX1/FX1E
12. Record of Self-diagnosis check
Page 7
Address B0 to C6
Note1: This data will be kept even if the lithium battery (FP-959 flexible
BT591) is removed.
Note2: The data of page: 0, address: 10 must be “00”.
Address
Self-diagnosis code
B0
“Repaired by” code (Occurred 1st time)   *1
B1
“Block function” code (Occurred 1st time)
B2
“Detailed” code (Occurred 1st time)
B4
“Repaired by” code (Occurred 2nd time)   *1
B5
“Block function” code (Occurred 2nd time)
B6
“Detailed” code (Occurred 2nd time)
B8
“Repaired by” code (Occurred 3rd time)   *1
B9
“Block function” code (Occurred 3rd time)
BA
“Detailed” code (Occurred 3rd time)
BC
“Repaired by” code (Occurred 4th time)   *1
BD
“Block function” code (Occurred 4th time)
BE
“Detailed” code (Occurred 4th time)
C0
“Repaired by” code (Occurred 5th time)   *1
C1
“Block function” code (Occurred 5th time)
C2
“Detailed” code (Occurred 5th time)
C4
“Repaired by” code (Occurred the last time)   *1
C5
“Block function” code (Occurred the last time)
C6
“Detailed” code (Occurred the last time)
*1: “01” 
t “C”, “03” t “E”
Using method:
1)
The past self-diagnosis codes are displayed at addresses: B0 to C6. Refer to “SELF-DIAGNOSIS CODE TABLE” for detail of the self-
diagnosis code.
Initializing method:
1)
Select page: 7, address: 01, and set data: C0.
2)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
3)
Check that the data of page: 7, address: B0 to C7 are “00”.
4)
Select page: 7, address: 00, and set data: 00.
5)
Select page: 7, address: 01, and set data: 00.
Page of 86