DOWNLOAD Sony HDR-CX570E / HDR-CX580E / HDR-CX580V / HDR-CX580VE / HDR-CX590V / HDR-PJ580 / HDR-PJ580E / HDR-PJ580V / HDR-PJ580VE / HDR-PJ590V / HDR-PJ600 / HDR-PJ600E / HDR-PJ600V / HDR-PJ600VE (serv.man2) Service Manual ↓ Size: 7.58 MB | Pages: 37 in PDF or view online for FREE

Model
HDR-CX570E HDR-CX580E HDR-CX580V HDR-CX580VE HDR-CX590V HDR-PJ580 HDR-PJ580E HDR-PJ580V HDR-PJ580VE HDR-PJ590V HDR-PJ600 HDR-PJ600E HDR-PJ600V HDR-PJ600VE (serv.man2)
Pages
37
Size
7.58 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
hdr-cx570e-hdr-cx580e-hdr-cx580v-hdr-cx580ve-hdr-c.pdf
Date

Sony HDR-CX570E / HDR-CX580E / HDR-CX580V / HDR-CX580VE / HDR-CX590V / HDR-PJ580 / HDR-PJ580E / HDR-PJ580V / HDR-PJ580VE / HDR-PJ590V / HDR-PJ600 / HDR-PJ600E / HDR-PJ600V / HDR-PJ600VE (serv.man2) Service Manual ▷ View online

1-5
HDR-CX570E/CX580E/CX580V/CX580VE/CX590V/PJ580/PJ580E/PJ580V/PJ580VE/PJ590V/PJ600E/PJ600V/PJ600VE_L2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
4
0
1
Internal flash memory fault
CX580E/CX580V/CX580VE/PJ580/PJ580E/PJ580V/PJ580VE:
Inspect the flash memory (IC8101 on the LD-279 board).
CX590V/PJ590V:
Inspect the flash memory (IC8101, IC8201 on the LD-279 board).
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-653 board).
E
9
5
0
0
GPS hardware error
CX580V/CX580VE/CX590V/PJ580V/PJ580VE/PJ590V/PJ600V/
PJ600VE:
Check whether the FFC-254 flexible flat cable is broken,and check 
whether it is inserted imperfectly.
If there is no problem the flexible board, inspect or replacement of 
the GP-037 board.
E
9
6
0
0
Map area mount error
CX580V/CX580VE/CX590V/PJ580V/PJ580VE/PJ590V/PJ600V/
PJ600VE:
Inspect or replacement of the LD-279 board.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-7.
  METHOD OF COPING WITH SHIFT LENS ERROR
LD-279 BOARD (SIDE A)
IC5501
R5505
C5526
C5529
C5528
C5527
Fig. 1
Measurement points on the LD-279 board
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2012.01
about 330 msec
Note: The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of R5505 on the LD-279 board
1-7
-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5505 in the periphery of IC5501 on the LD-279 board, turn the 
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect 
the camera control circuit (IC1301 of VC-653 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-7
-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred 
Order
AdjustBlock
AdjustCode
Order
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the 
[SERVICE] tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage of C5526 and C5527 in 
the periphery of IC5501 on the LD-279 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of R5505 in the periphery of IC5501 on the 
LD-279 board, turn the power ON to check that the output voltage immediately after the power on 
change as shown in Fig. 2.
7
If the output voltage change as shown in Fig. 2, replace the lens block(Note).
If it does not change as shown in Fig. 2, inspect the camera control circuit (IC1301 of VC-653 board 
and IC5501 of LD-279 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
 
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-6
HDR-CX570E/CX580E/CX580V/CX580VE/CX590V/PJ580/PJ580E/PJ580V/PJ580VE/PJ590V/PJ600E/PJ600V/PJ600VE_L2
1-7
-3.E : 62 : 12 [Shift Lens Overheating (Yaw)] Occurred
Order
AdjustBlock
AdjustCode
Order
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SER-
VICE] tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage of C5528 and C5529 in the 
periphery of IC5501 on the LD-279 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of R5505 in the periphery
of IC5501 on the LD-279 board, turn the power ON to check that the output voltage
immediately after the power on change as shown in Fig. 2.
7
If the output voltage change as shown in Fig. 2, replace the lens block(Note).
If it does not change as shown in Fig. 2, inspect the camera control circuit (IC1301 of VC-653 board 
and IC5501 of LD-279 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
 
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-7
-4. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
Procedure
1
Turn the power ON.
2
Confirm the connections of flexible flat cables and connectors between the lens block and LD-279 board.
3
In case of no malfunction of connections, replace the lens block with new one (Note) . When the error has occurred in spite of the lens 
replacement, replace LD-279 board with new one.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2012.01
– ENGLISH –
1-8.
  GPS RECEIVING CHECK (CX580V/CX580VE/CX590V/PJ580V/PJ580VE/PJ590V/PJ600V/
PJ600VE)
After a part of set was replaced or after the set was assembled, check the reception of GPS signal.
How to check the GPS function
Bring your camcorder to an open area, and set the GPS to ON (
 appears on the LCD screen). Your camcorder starts trying to triangulate. When 
your camcorder triangulates successfully, it will record the location information at the time movies and photos were recorded. 
• The indicator changes according to the strength of GPS signal reception.
• It may take a while before the camcorder starts triangulating.
To return the display of the unit to “A message appears asking you to confirm whether you agree with the terms of the license agreement of the map
data,” make settings according to the instructions on the SERVICE tab in the Adjustment Manual.
Use GPS Assist Data
If you import GPS Assist Data from your computer to your camcorder using the supplied software “PlayMemories Home,” the time it takes the cam-
corder to acquire your location information can be shortened.
Connect the camcorder to a computer that is connected to the Internet. The GPS Assist Data will be updated automatically.
1-9.
  PRECAUTION ON REPLACING THE LD-279 BOARD (CX580V/CX580VE/CX590V/PJ580V/
PJ580VE/PJ590V/PJ600V/PJ600VE)
Do not factory check LD-279 board (CX580V/CX580VE/CX590V/PJ580V/PJ580VE/PJ590V/PJ600V/PJ600VE) in which Map Data is installed.
The Map data is erased when the factory check is done.
1-10. PRECAUTION ON REPLACING THE HDD (PJ600V/PJ600VE)
Do not factory check the HDD (PJ600V/PJ600VE) in which Map Data is installed.
The Map Data is erased when the factory check is done.
1-7
HDR-CX570E/CX580E/CX580V/CX580VE/CX590V/PJ580/PJ580E/PJ580V/PJ580VE/PJ590V/PJ600E/PJ600V/PJ600VE_L2
– ENGLISH –
1-11.
 DISCHARGE OF LED FLASH/VIDEO LIGHT
This model is provided with a flash unit using LED Flash/Video light.
Therefore, the LED Flash/Video light does not have high voltage part and does not need to be discharged.
1-12.
  NOTE ON REPLACING PROJECTOR UNIT 
(PJ580/PJ580E/PJ580V/PJ580VE/PJ590V/PJ600E/PJ600V/PJ600VE)
Refer to the following flowchart when repairing or inspecting the projector’s projection function.
If you have received an indication on the projector’s projection function from the customer, check defective part according to the following flow-
chart. 
When a defective part has been clarified, repair the projector according to the check result.
Note 1: The projector unit (copper plate in particular) becomes hot after it is used.
 
When replacing a part of the projector unit, wait until it is cooled down.
 
Wipe the lens gently with a soft cloth such as a cleaning cloth or glass cleaning cloth.
Note 2: Stubborn stains may be removed with a soft cloth such as a cleaning cloth or glass cleaning cloth lightly dampened with water.
 
Never use a solvent such as alcohol, benzene or thinner; acid, alkaline or abrasive detergent; or a chemical cleaning cloth, as they will damage the lens sur-
face.
Projector problem checking procedure (other than indication on brightness)
Indicated defective
projector received
Measure brightness.
(  2)
Yes
No
OK
OK
NG
NG
OK
NG
A
B
Indication on 
brightness
Inspect projector
LED. 
(  1)
  1  Refer to the ADJUST tab of Adjust Manual.
  2  Refer to the SERVICE tab of Adjust Manual.
Inspect projector
LED. 
(  1)
END
-
-
-
-
-
Replace projector unit (light emitting block). (*1)
Replace PJ board. (*1)
Replace both projector unit (light emitting block)
and PJ board. (*1)
Projector Data Input
Fixed value input
Enter the number on the label attached to the unit.
Serial number input
LD40
Syywwnnnnn 
Enter the red part.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2012.01
Projector problem checking procedure (indication on brightness)
Yes
No
OK
NG
OK
NG
OK
NG
A
B
Indicated defective
projector received
Measure brightness.
(  2)
Measure brightness.
(  2)
Indication on 
brightness
Inspect projector
LED. 
(  1)
  1  Refer to the ADJUST tab of Adjust Manual.
  2  Refer to the SERVICE tab of Adjust Manual.
END
-
-
-
-
-
Replace projector unit (light emitting block). (*1)
Replace PJ board. (*1)
Replace both projector unit (light emitting block)
and PJ board. (*1)
Projector Data Input
Fixed value input
Enter the number on the label attached to the unit.
Serial number input
LD40
Syywwnnnnn 
Enter the red part.
1-8
HDR-CX570E/CX580E/CX580V/CX580VE/CX590V/PJ580/PJ580E/PJ580V/PJ580VE/PJ590V/PJ600E/PJ600V/PJ600VE_L2
– JAPANESE –
1-1.  修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
ACアダプタを使用する。
1-2.  VC-653基板交換時の注意
基板交換時は,下記の点に注意してください。
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
補修用基板交換後、電源を入れると内蔵記録メディアエラーが表示される場合がありますが、「DESTINATION  DATA  WRITE」を実行
させると消えます。「DESTINATION DATA WRITE」実行しても消えない場合は、内蔵記録メディアをフォーマットしてください。
USBシリアルセーブ
補修用基板と交換する時,交換前の基板よりUSBシリアルNo.を取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「USB SERIAL SAVE」を実行させてください。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB SERIAL No. INPUT」を実行させてください。
プロジェクター用のデータ (PJ580/PJ580E/PJ580V/PJ580VE/PJ590V/PJ600E/PJ600V/PJ600VE)
補修用基板と交換する時,交換前の基板より下記のデータを取得してください。
・  Fixed value(プロジェクターの照射性能を示す値)。
・  Serial number(プロジェクターユニットの製造シリアル番号)。
データの取得はAdjust StationからAdjustManualを起動させて、[DATA]タブにある[Projector Data Reference]を参照してください。
内蔵メモリー搭載機について
補修用基板に交換後は,最初に下記の手順を実行してください。
1.  Adjust ManualのADJUSTタブにある,「DESTINATION DATA WRITE」を実行する。
2.  下記のスクリプトファイルを実行する。
 
・  11DdmMmcReadTestMINI_v4.vbe
 
・  11DdmMmcMakePartition_v4.vbe
Note:  スクリプトファイルはTISSホームページより入手してください。
 
TISSホームページで検索する際はPart Number欄に
「IM_VC_TOOL」
と入力して検索してください。
このスクリプトファイルを実行しなかった場合,以下のような症状が発生する可能性があります。
必ず上記のスクリプトを実行してください。
・  内蔵メモリーがメディアとして認識できない
・  内蔵メモリー内に保存されている,管理ファイルの修復ができない
・  内蔵メモリーのフォーマットができない
START
END
セットが自動的に再起動される
USB接続を解除し、電源を切る
“USB接続”を選択し、
USB接続を行う
DdmMmcReadTestMINI.vbe
を実行
(数秒後)
“SetOverallReadMINI OK”表示
(約10秒後)
セットが自動的に再起動される
11DdmMMCMakePartition.vbe
を実行
(数秒後)
“MakePartition OK”表示
電源を入れたまま、
ACアダプタを抜き挿しする
処理は自動で実行される
(Blue画面)
セットをPCにUSB接続し、電源を入れる
* PC
はSeusEX がインストール済で,
SeusEXへの接続が可能であること
Fig.1
Page of 37
Display

Click on the first or last page to see other HDR-CX570E / HDR-CX580E / HDR-CX580V / HDR-CX580VE / HDR-CX590V / HDR-PJ580 / HDR-PJ580E / HDR-PJ580V / HDR-PJ580VE / HDR-PJ590V / HDR-PJ600 / HDR-PJ600E / HDR-PJ600V / HDR-PJ600VE (serv.man2) service manuals if exist.