1. SERVICE  NOTE
1-1.  POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off 
so that the unit cannot operate.
These following method is available to prevent this.
Method:
Use the AC adaptor (AC-L100C).
1-2.  PRECAUTION ON REPLACING THE VC-582 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “Destination data write”.
USB SERIAL SAVE
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “USB SERIAL SAVE” to get the data.
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB serial No. input”.
– ENGLISH –
1-3. SELF-DIAGNOSIS FUNCTION
1-3-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the Viewfinder or the LCD 
screen what to do. This function consists of two display; selfdiag-
nosis display and service mode display.
Details of the self-diagnosis functions are provided in the Instruc-
tion manual.
1-3-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the 
Viewfinder or the LCD screen shows a 4-digit display consisting of 
an alphabet and numbers, which blinks at 3.2 Hz. This 5-character 
display indicates the “repaired by:”, “block” in which the problem 
occurred, and “detailed code” of the problem.
1 1
3 1
C
Repaired by:
Refer to “1-3-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C :  Corrected by customer
H :  Corrected by dealer
E :  Corrected by service
 engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
1-3-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Format the memory card.
Insert a new memory card.
C
1
3
0
4
The external storage media has connected 
loose.
Insert again the external storage media precisely.
Abnormality occurs in the external stor-
age media.
Format again the external storage media.
The external storage media is broken.
Replace it with new one.
Abnormality occurs in between the main 
and the external storage media.
Turn power off and turn power on again.
C
3
2
6
0
Difficult to adjust focus 
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not 
recover, check the focus MR sensor of lens block (pin 0, qs 
of CN6602 on the VC-582 board). If it is OK, check the focus 
motor drive IC (IC6002 on the VC-582 board).
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom MR sensor (pin es, ef of CN6602 
on the VC-582 board) when zooming is performed when the 
zoom lever is operated, or the zoom motor drive circuit (IC6002 
on the VC-582 board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of 
the focus lens and the abnormalities in 
initialization of the zoom lens occurred 
simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis 
code.
E
6
1
3
0
Reset position detect error when stepper 
iris is initialized.
Turn on the power and set to T (telephoto) end by rotating the 
ZOOM manual ring. While observing the iris blades in the 
lens, turn on the power again and check the iris blades in the 
lens work properly. Inspect the iris drive motor of lens drive 
block (Pin qh to ql of CN6602 on the VC-582 board), when 
the iris does not operate. Inspect the iris reset sensor of lens 
drive block (Pin qd to qg of CN6602 on the VC-582 board), 
when the iris operate.
E
6
2
0
0
Steadyshot function does not work well. 
(With pitch angular velocity sensor out-
put stopped.)
Inspect pitch angular velocity sensor (SE8501 on the GY-022 
board) peripheral circuits.
E
6
2
0
1
Steadyshot function does not work 
well. 
(With yaw angular velocity sensor output 
stopped.)
Inspect yaw angular velocity sensor (SE8502 on the GY-022 
board) peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Inspect the steadyshot circuit (IC6401 on the VC-582 board). 
If it does not recover, replace the VC-582 board. (Note 2) If 
an error occurs again, replace the lens block.
E
6
2
0
3
IC for steadyshot and micro controller 
communication abnormality among.
Inspect the steadyshot circuit (IC6401 on the VC-582 board).
E
6
2
1
0
Shift lens initializing failure
Inspect the EEPROM (IC5602 on the VC-582 board). If it does 
not recover, replace the VC-582 board. (Note 2) If an error 
occurs again, replace the lens block.
Note 1: Start the Adjust Manual in the Adjust Station and refer to the “Destination data write”.
Note 2: When replacing the VC-582 board, remove the EEPROM (IC5602) from the VC-582 board that is going to be repaired. Install the removed EEPROM 
(IC5602) to the replaced VC-582 board.
HDR-AX2000/AX2000E_L2
1-2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
2
1
1
Shift lens overheating (Pitch)
Inspect the IC6401 and peripheral circuits on the VC-582 board. 
If it does not recover, replace the VC-582 board. (Note) If an 
error occurs again, replace the lens block.
E
6
2
1
2
Shift lens overheating (Yaw)
Inspect the IC6401 and peripheral circuits on the VC-582 board. 
If it does not recover, replace the VC-582 board. (Note) If an 
error occurs again, replace the lens block.
E
6
2
2
0
Abnormality of lens thermister
Inspect the IC6401 and peripheral circuits on the VC-582 board. 
If it does not recover, replace the VC-582 board. (Note) If an 
error occurs again, replace the lens block.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom 
maybe depended on the remaining battery level, and confirm 
whether or not the symptom is occurred after replacing the 
battery.
If the symptom is still occurred, overhaul inspection is 
needed.
Connect the GC-012 board with VC-582 board through the 
FP-1161
 (VC-GC) flexible board.
Connect the GC-012 board with Control Switch Block 
(PS94000).
Check each output of DC/DC converter (IC5201) on VC-582 
board with connected the DC/Batt harness (the minimum con-
nection to periphery) to VC-582 board.
E
9
4
0
0
Fault of writing or erasing the flash 
memory
Inspect the flash memory (IC2601 on the VC-582 board).
E
9
4
0
1
Internal flash memory fault
Inspect the flash memory (IC2601 on the VC-582 board).
E
9
4
0
2
BGM data error
Inspect the flash memory (IC2601 on the VC-582 board). If it 
is OK, check the CPU (IC2001 on the VC-582 board).
Note:   When replacing the VC-582 board, remove the EEPROM (IC5602) from the VC-582 board that is going to be repaired. Install the removed EEPROM 
(
IC5602
) to the replaced VC-582 board.
1-4.  PRECAUTION ON REPLACING THE GY-022 BOARD
Angular Velocity Sensor
When you replace to the reparing board, write down the sensitivity displayed on the angular velocity sensor (SE8501, SE8502).
Start the Adjust Manual in the Adjust Station and execute the “GYRO sensor sensitivity adj”.
GY-022 BOARD (SIDE A)
SE8501
(PITCH SENSOR)
SE8502
(Y
A
W SENSOR)
PP
YY
PP:
PITCH sensor sensitivity 
t
 G
1
YY:
YAW sensor sensitivity 
t
 G
2
Note:  The sensor sensitivity of SE8501, SE8502 of GY-022 board is written only repair parts.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2010.02
HDR-AX2000/AX2000E_L2
1-3
1-1.  修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
ACアダプタ(AC-L100C)を使用する。
1-2.  VC-582基板交換時の注意
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「Destination data write」を実行させてください。
USBシリアルセーブ
補修用基板と交換する時,交換前の基板よりUSBシリアルNo.を取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「USB SERIAL SAVE」を実行させてください。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB serial No. input」を実行させてください。
– JAPANESE –
1-3.  自己診断機能
1-3-1. 自己診断機能について
本機の動作に不具合が生じたとき,自己診断機能が働き,
ビューファインダまたはL  C  D  画面に,どう処置したらよ
いか判断できる表示を行います。
「自己診断表示」と「サービ
スモード表示」の2つの表示があります。自己診断機能につ
いては取扱説明書にも掲載されています。
1-3-2. 自己診断表示
本機の動作に不具合が生じたとき,ビューファインダまた
はLCD画面のカウンタ表示部分がアルファベットと数字の
4桁表示になり,3  .  2  H  z  で点滅します。この5  文字の表
示によって対応者分類および不具合の生じたブロックの分
類,不具合の詳細コードを示します。
1 1
3 1
C
ኻᔕ⠪ಽ㘃
ޟ  ⥄Ꮖ⸻ᢿࠦ࡯࠼⴫ޠ
ࠍෳᾖ
ኻᔕᣇᴺߩ㆑޿ߦࠃࠅಽ㘃
଀  㨯㨯㨯࠹࡯ࡊࠍ౉ࠇ⋥ߔ
 㨯㨯㨯㔚Ḯࠍ౉ࠇ⋥ߔ
ࡉࡠ࠶ࠢಽ㘃
⹦⚦ࠦ࡯࠼
*\ὐṌ
% 㧦߅ቴߐ߹⥄りߢኻᔕ
* 㧦⽼ᄁᐫߢኻᔕ
' 㧦ࠨ࡯ࡆࠬࠛࡦࠫ࠾ࠕ
ߢኻᔕ
ࡆࡘ࡯ࡈࠔࠗࡦ࠳߹ߚߪ.%&↹㕙
C : 3 1 : 1 1
1-3-3. 自己診断コード表
自己診断コード
症状/状態
対応/方法


ブロック
機能
詳細
コード
C
0
4
0
0
標準でないバッテリを使用している
インフォリチウムバッテリを使用する。
C
0
6
0
0
バッテリが高温になっている
バッテリを交換するか、バッテリを涼しいところに置
く。
C
1
3
0
1
フォーマットしていないメモリー
カードを入れたメモリーカードが壊
れている
メモリーカードをフォーマットする。
新しいメモリーカードに交換する。
C
1
3
0
4
外部メディアの装着接触不良があっ
外部メディアを装着しなおす。
外部メディアに異常が発生した
外部メディアをフォーマットしなおす。
外部メディアが壊れている
新しい外部メディアに交換する。
外部メディアと本体との間でなんら
かの異常があった
電源を入れ直す。
C
3
2
6
0
フォーカスが合いにくい
(フォーカスの初期化ができない)
操作スイッチの電源を入れ直す。
復帰しない場合,レンズブロックのフォーカスMRセン
サ(VC-582基板CN6602 0,qsピン)を点検する。
異常なければフォーカスモータ駆動回路(VC-582基板
IC6002)を点検する。
E
2
0
0
0
フラッシュメモリが書き換えられて
いる
フラッシュメモリのデータを元の値に戻す。(注意1)
E
6
1
1
0
ズーム動作の異常
(ズームレンズの初期化ができない)
ズ ー ム レ バ ー を 操 作 し た と き に ズ ー ム 動 作 を す れ
ば,レンズブロックのズームMRセンサ(VC-582基板
CN6602 es,efピン)を点検する。
ズ ー ム 動 作 を し な け れ ば ズ ー ム モ ー タ 駆 動 回 路
(VC-582基板IC6002)を点検する。
E
6
1
1
1
フォーカスレンズ初期化異常,ズー
ムレンズ初期化異常の同時発生
自己診断コードC:32:60とE:61:10の両方を点検
する。
E
6
1
3
0
ステッパアイリス初期化時リセット
位置検出エラー
電 源 投 入 後, ズ ー ム マ ニ ュ ア ル リ ン グ を 回 し てT
(telephoto)端にする。レンズ内のアイリス羽に注目し
ながら電源を再投入し,レンズ内の羽が動作している
か確認する。アイリスが動作しない場合は,レンズド
ライブブロックのアイリスモータドライブ(VC-582基
板CN6602 qh ∼ qlピン)を点検。
アイリスが動作する場合は,レンズドライブブロック
のアイリスリセットセンサ
(VC-582基板CN6602 qd ∼ qg
ピン)を点検。
E
6
2
0
0
手振れ補正が効きにくい
(PITCH角速度センサ出力張り付き)
PITCH角速度センサ(GY-022基板SE8501)周辺回路を
点検。
E
6
2
0
1
手振れ補正が効きにくい
(YAW角速度センサ出力張り付き)
YAW角速度センサ(GY-022基板SE8502)周辺回路を点
検。
E
6
2
0
2
手振れ補正用ICの異常
手振れ補正回路(VC-582基板IC6401)を点検。復帰し
ない場合,VC-582基板を交換する。(注意2)エラーが
再度発生する場合は,レンズブロックを交換する。
E
6
2
0
3
手振れ補正用ICとマイクロコント
ローラとの通信異常
手振れ補正回路(VC-582基板IC6401)を点検。
E
6
2
1
0
シフトレンズ初期化異常
EEPROM(VC-582基板IC5602)を点検。復帰しない場
合,VC-582基板を交換する。(注意2)エラーが再度発
生する場合は,レンズブロックを交換する。
E
6
2
1
1
シフトレンズオーバーヒート
(PITCH)
VC-582基板のIC6401および周辺回路を点検。復帰し
ない場合,VC-582基板を交換する。(注意2)エラーが
再度発生する場合は,レンズブロックを交換する。
注意1:  Adjust StationからAdjust Manualを起動させて,「 Destination data write 」を参照してください。
注意2:   VC-582基板を交換する場合は,修理するVC-582基板からEEPROM(IC5602)を取り外してください。取り外したEEPROM 
(IC5602)は取り替えたVC-582基板に取り付けてください。
HDR-AX2000/AX2000E_L2
1-4E
– JAPANESE –
自己診断コード
症状/状態
対応/方法


ブロック
機能
詳細
コード
E
6
2
1
2
シフトレンズオーバーヒート
(YAW)
VC-582基板のIC6401および周辺回路を点検。復帰し
ない場合,VC-582基板を交換する。(注意)エラーが再
度発生する場レンズブロックを交換する。
E
6
2
2
0
レンズサーミスタの異常
VC-582基板のIC6401および周辺回路を点検。復帰し
ない場合は,VC-582基板を交換する。(注意)エラーが
再度発生する場合は,レンズブロックを交換する。
E
9
2
0
1
(バッテリーの)電流値が最大放電電
流を超えた
バッテリ残量に依存する場合があるので,バッテリ残
量を確認する。
次にバッテリを交換して症状が出るか確認する。
バッテリを交換しても症状が出る場合は,エラー発
生後に電源が切れてしまうため,分解して確認する。
VC-582基板にGC-012基板を
FP-1161
  (VC-GC)  フレキ
シブル基板で接続する。
GC-012基 板 と コ ン ト ロ ー ル ス イ ッ チ ブ ロ ッ ク
(PS94000)を接続する。
DC/バッテリハーネスをVC-582基板に接続した状態 
(最小限の接続)  でDC / DCコンバータ  (VC-582基板
IC5201) の各チャンネル出力を確認する。
E
9
4
0
0
フラッシュメモリの書込み/消去動
作不良
フラッシュメモリ(VC-582基板 IC2601)を点検する。
E
9
4
0
1
フラッシュメモリ内部異常
フラッシュメモリ(VC-582基板 IC2601)を点検する。
E
9
4
0
2
BGM データ異常
フラッシュメモリ(VC-582基板 IC2601)を点検する。
異常がない場合は,CPU(VC-582基板  IC2001)を点検
する。
注意:   VC-582基板を交換する場合は,修理するVC-582基板からEEPROM(IC5602)を取り外してください。取り外したEEPROM (
IC5602
は取り替えたVC-582基板に取り付けてください。
1-4.  GY-022基板交換時の注意
角速度センサ
補修用基板と交換する時,角速度センサ(SE8501,SE8502)の感度表示を書き留めてください。
Adjust StationからAdjust Manualを起動させて「GYRO sensor sensitivity adj.」を実行させてください。
GY-022 BOARD (SIDE A)
SE8501
(PITCH
センサー)
SE8502
(Y
A
W
センサー
)
PP
YY
PP:
PITCH 
感度表示 
t
 G
1
YY:
YAW
感度表示 
t
 G
2
Note:  GY-022基板のSE8501, SE8502感度表示は補修用基板にのみ記載されています。
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2010.02
Page of 70
Display

Click on the first or last page to see other HDR-AX2000 / HDR-AX2000E (serv.man2) service manuals if exist.