Sony DCR-VX2200E Service Manual ▷ View online

1-2
DCR-VX2200E_L2
1-5. SELF-DIAGNOSIS FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder or LCD
screen what to do.
Details of the self-diagnosis functions are provided in the Instruction
manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
viewfinder or LCD screen shows a 4-digit display consisting of an
alphabet and numbers, which blinks at 3.2 Hz. This 5-character
display indicates the “repaired by:”, “block” in which the problem
occurred, and “detailed code” of the problem.
1 1
3 1
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
1-4. USING SERVICE JIG
Connect the CPC-13 jig (J-6082-443-A) to the CN1004 on the VC-597 board.
Pin No.
Signal Name
Pin No.
Signal Name
1 (20)
REG_GND
11 (10)
EEP_SO_C
2 (19)
RF_MON
12 (9)
EEP_SO_S
3 (18)
REG_GND
13 (8)
EEP_SCK_C
4 (17)
SWP
14 (7)
EEP_SCK_S
5 (16)
FRRV
15 (6)
D_2.8V
6 (15)
REG_GND
16 (5)
MD2_C
7 (14)
GND
17 (4)
MD2
8 (13)
GND
18 (3)
XCS_MC_FLASH_C
9 (12)
EEP_SI_C
19 (2)
XCS_MC_FLASH
10 (11)
EEP_SI_S
20 (1)
XSYS_RST
Note: The pin number in (  ) is test terminal number of
CN1004 on the VC-597 board.
1
20
CN1004
VC-597 BOARD (SIDE B)
11
10
20
1
1
20
CPC-13
(J-6082-443-A)
1-3
DCR-VX2200E_L2
1-5-3. Self-diagnosis Code Table
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Block
Function
0
4
0
6
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Detailed
Code
0
0
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
7
2
9
7
9
8
9
9
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
6
0
Symptom/State
Non-standard battery is used.
The battery is too hot.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
S reel side tape slacking when unloading.
T reel fault.
S reel fault.
T reel and S reel  FG short fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum operations.
Retry fault when catching one’s finger
in cassette compartment.
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
S reel side tape slacking when
unloading.
T reel fault.
S reel fault.
T reel and S reel  FG short fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum
operations.
Difficult to adjust focus
(Cannot initialize focus.)
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Replace the battery or remove it and put it in cool place.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
If it does not recover, inspect the focus MR sensor of lens drive
block (Pin q;, qs of CN5002 on the VC-597 board).
If not faulty, inspect the focus motor drive circuit
(IC6001 on the VC-597 board).
1-4E
DCR-VX2200E_L2
C
C
C
C
E
E
E
E
E
E
E
E
E
E
E
E
Block
Function
3
2
3
2
3
2
3
2
2
0
6
1
6
1
6
1
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
Detailed
Code
7
2
9
7
9
8
9
9
0
0
1
0
1
1
3
0
0
0
0
1
0
2
0
3
1
0
1
1
1
2
2
0
Symptom/State
Retry fault when catching one’s finger
in cassette compartment.
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
Vector fault (Judgement with the set
state that is impossible actually for fault
of sensors.)
EEPROM data are rewritten.
Zoom operations fault
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur simulta-
neously.
Reset position detect error when
stepper iris is initialized.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure
Shift lens overheating (Pitch)
Shift lens overheating (Yaw)
Abnormality of lens thermister
Self-diagnosis Code
Repaired b
y:
Correction
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Make EEPROM data correct value.
Inspect the zoom MR sensor of lens drive block (Pin es, ef of
CN5002 on the VC-597 board) when zooming is performed when
the zoom switch is operated and the zoom motor drive circuit
(IC6001 on the VC-597 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Turn on the power and set to T (telephoto) end by rotating the
ZOOM manual ring. While observing the iris blades in the lens,
turn on the power again and check the iris blades in the lens
work properly. Inspect the iris drive motor of lens drive block
(Pin qh to ql of CN5002 on the VC-597 board), when the iris
does not operate. Inspect the iris reset sensor of lens drive block
(Pin qd to qg of CN5002 on the VC-597 board), when the iris
operate.
Inspect pitch angular velocity sensor (SE8501 on the GY-014
board) peripheral circuits.
Inspect yaw angular velocity sensor (SE8502 on the GY-014
board) peripheral circuits.
Inspect the steadyshot circuit (IC7001 on the VC-597 board). If
it does not recover, replace the VC-597 board. (Note) If an error
occurs again, replace the lens block.
Inspect the steadyshot circuit (IC7001 on the VC-597 board).
Inspect the EEPROM (IC4202 on the VC-597 board). If it does
not recover, replace the VC-597 board. (Note) If an error occurs
again, replace the lens block.
Inspect the IC7001 and peripheral circuits on the VC-597 board.
If it does not recover, replace the VC-597 board. (Note) If an
error occurs again, replace the lens block.
Inspect the IC7001 and peripheral circuits on the VC-597 board.
If it does not recover, replace the VC-597 board. (Note) If an
error occurs again, replace the lens block.
Inspect the IC7001 and peripheral circuits on the VC-597 board.
If it does not recover, replace the VC-597 board. (Note) If an
error occurs again, replace the lens block.
Note:
When replacing the VC-597 board, remove the EEPROM (IC4202) from the VC-597 board that is going to be repaired. Install the removed EEPROM
(IC4202) to the replaced VC-597 board.
2-1
2. DISASSEMBLY
DCR-VX2200E_L2
NOTE  FOR  REPAIR
• Make sure that the flat cable and flexible board are not cracked of bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
• When remove a connector, don’t pull at wire of connector. It is possible that a wire is snapped.
• When installing a connector, don’t press down at wire of connector.
It is possible that a wire is snapped.
Cut and remove the part of gilt 
which comes off at the point.
(Be careful or some 
pieces of gilt may be left inside) 
Harness 
(coaxial cable)
Tweezers etc.
NOTE  FOR  DISCONNECTING  THE  HARNESS (COAXIAL CABLE)
When disconnecting the harness (COAXIAL CABLE), do not
pull the harness part but pull off the connector body with tweezers
etc.
Page of 113