Movie / SECTION 6 ADJUSTMENTS
File
dcr-vx2100-dcr-vx2100e-sm4.pdf
Date

Sony DCR-VX2100 / DCR-VX2100E (serv.man4) Service Manual ▷ View online

6-34
DCR-VX2100/VX2100E
6. Center Level Adjustment (PD-217 board)
Set the video signal center level of LCD panel to an appropriate
level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 1 of CN2105 (VG)
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
AB
Specified Value
A = 7.00 
±
 0.05Vdc
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
20
Set the data, and press PAUSE
button.
3
3
22
08
Set the data, and press PAUSE
button.
4
D
AB
Change the data and set the DC
voltage (A) to the specified
value.
(The data should be “00” to
“7F”.)
5
D
AB
Press PAUSE button.
6
3
0C
00
Set the data, and press PAUSE
button.
7
3
22
00
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
5. Contrast Adjustment (PD-217 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 1 of CN2105 (VG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
AA
Specified Value
A = 2.70 
±
 0.05V
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
AA
Change the data and set the
voltage (A) between the 3 steps
peak and pedestal to the
specified value.
(The data should be “00” to
“7F”.)
3
D
AA
Press PAUSE button.
4
0
01
00
Set the data.
5
Check that the specified value of
“Bright Adjustment” is satisfied.
3 steps peak
Pedestal
A
2H
Fig. 6-1-23.
6-35
DCR-VX2100/VX2100E
7. V-COM Adjustment (PD-217 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
A4
Specified Value
The brightness difference between the
section A and section B is minimum.
Note: Perform “Bright Adjustment”, “Black Limit Adjustment”, “Contrast
Adjustment” and “Center Level Adjustment” before this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
B0
Write down the data.
3
D
B0
CA
Set the data, and press PAUSE
button.
4
D
A4
Change the data so that the
brightness of the section A and
that of the section B is equal.
5
D
A4
Subtract 1 from the data.
6
D
A4
Press PAUSE button.
7
D
B0
Write the data that was written
down in the step 2.
8
D
B0
Press PAUSE button.
9
0
01
00
Set the data.
A
A
A
A
B
B
B
B
Fig. 6-1-24.
8. White Balance Adjustment (PD-217 board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
A8, A9
Specified Value
The LCD screen should not be
colored.
Note1: Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC2101
Note2: Use the AC power adaptor.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
A8
85
Set the data, and press PAUSE
button.
3
D
A9
75
Set the data, and press PAUSE
button.
4
D
A9
Check that the LCD screen is
not colored. If not colored,
proceed to step 10.
5
D
A8
Change the data so that the LCD
screen is not colored.
6
D
A8
Press PAUSE button.
7
D
A9
Change the data so that the LCD
screen is not colored.
8
D
A9
Press PAUSE button.
9
D
A9
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
6-36
DCR-VX2100/VX2100E
6-2. MECHANISM SECTION
ADJUSTMENT
On the mechanism section adjustment
For details of mechanism section adjustments, checks,
and replacement of mechanism parts, refer to the separate
volume “DV MECHANICAL ADJUSTMENT MANUAL 
C Mechanism  ”.
2-1.
HOW TO ENTER RECORD MODE WITHOUT
CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, set data: 0C, and press the PAUSE
button of the adjustment remote commander.
(The mechanism enters the record mode automatically.)
Note: The function buttons become inoperable.
5)
To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander.  (Whenever you want to quit the record mode, be
sure to quit following this procedure.)
2-2.
HOW TO ENTER PLAYBACK MODE
WITHOUT CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, set data: 0B, and press the PAUSE
button of the adjustment remote commander.
(The mechanism enters the playback mode automatically.)
Note: The function buttons become inoperable.
5)
To quit the playback mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander.  (Whenever you want to quit the playback mode,
be sure to quit following this procedure.)
2-3.
TAPE PATH ADJUSTMENT
1. Preparation for Adjustment
1)
Clean the tape running side (tape guide, drum, capstan shaft,
pinch roller, etc.).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
4)
Connect an oscilloscope to VC-358 board CN007 via the CPC-
13 jig (J-6082-443-A).
Channel 1: VC-358 board, CN007 Pin 2 (Note)
External trigger: VC-358 board, CN007 Pin 3
Note: Connect a 75 
 resistor between pins 2 of CN007 and 1
(GND).
75 
 resistor (Parts code: 1-247-804-11)
5)
Playback the alignment tape for tracking. (XH2-1)
6)
Select page: 3, address: 33, and set data: 08.
7)
Select page: 3, address: 26, and set data: 31.
8)
Check that the oscilloscope RF waveform is normal at the
entrance and exit.
If not normal, adjust according to the separate volume
“DV MECHANICAL ADJUSTMENT MANUAL 
C Mechanism ” .
CN007 of VC-358 board
2. Procedure after operations
1)
Connect the adjustment remote commander to the LANC jack
and set the HOLD switch to the ON position.
2)
Select page: 3, address: 26, and set data: 00.
3)
Select page: 3, address: 33, and set data: 00.
Fig. 6-2-1.
Pin No.
1
2
3
4
5
6
7
8
9
10
Signal Name
GND
RF MON
SWP
RF IN/LANC JACK IN
TDO
GND
TCK
TDI
PANEL COM
TMS
Pin No.
11
12
13
14
15
16
17
18
19
20
Signal Name
H START
XHD/PSIG
EVF VB
EVF VR
EVF VCO
GND
EVF BL –
EVF VG
LANC SIG
EVF BL +
CH1
Entrance side
Exit side
Check this section
(Normal waveform)
CH2
(Trigger)
3.3msec
6-37
DCR-VX2100/VX2100E
6-3. VIDEO SECTION ADJUSTMENTS
NTSC model : DCR-VX2100
PAL model :
DCR-VX2100E
3-1. PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1.
Equipment Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band above 30 MHz with
delay mode) (Unless specified otherwise, use a 10 : 1 probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal.
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) Alignment tapes
• Tracking standard (XH2-1)
Parts code: 8-967-997-01
• SW/OL standard (XH2-3)
Parts code: 8-967-997-11
• Audio operation check for NTSC (XH5-3)
Parts code: 8-967-997-51
• System operation check for NTSC (XH5-5)
Parts code: 8-967-997-61
• BIST check for NTSC (XH5-6)
Parts code: 8-967-997-71
• Audio operation check for PAL (XH5-3P)
Parts code: 8-967-997-55
• System operation check for PAL (XH5-5P)
Parts code: 8-967-997-66
• BIST check for PAL (XH5-6P)
Parts code: 8-967-997-76
12) Adjustment remote commander (J-6082-053-B)
13) CPC-13 jig (J-6082-443-A)
14) Extension cable (50P, 0.5 mm)
For extension between the CD-512 board (CN100) and the VC-