DOWNLOAD Sony DCR-VX2100 / DCR-VX2100E (serv.man4) Service Manual ↓ Size: 1.51 MB | Pages: 66 in PDF or view online for FREE

Model
DCR-VX2100 DCR-VX2100E (serv.man4)
Pages
66
Size
1.51 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-vx2100-dcr-vx2100e-sm4.pdf
Date

Sony DCR-VX2100 / DCR-VX2100E (serv.man4) Service Manual ▷ View online

6-14
DCR-VX2100/VX2100E
4. E Page Table
Note1: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F
Page Data”.)
Note2: Refer to “2. Modification of E, F Page Data” for the camera
microprocessor version.
Note3: NTSC model : DCR-VX2100
PAL model
: DCR-VX2100E
Table. 6-1-6.
8C
8D
8E
8F
90
91
92
93
94
95
96
97 to 9D
9E
9F to A0
A1
A2
A3
A4
A5
A6 to A7
A8
A9 to AB
AC
AD
AE to B0
B1
B2
B3
B4 to B9
BA
BB to C3
C4
C5 to CB
CC
CD
CE
CF to D9
DA
DB
DC to EB
EC
ED to F2
F3
F4
F5
F6
F7
F8
F9
FA to FD
FE
FF
00
00
EB
D5
20
20
00
00
EB
D5
20
20
Fixed data-2
WB ND filter 2 compensation
Color reproduction adj. (ND filter 2)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
00 to 03
04
05
06
07
08 to 10
11
12 to 13
14
15 to 29
2A
2B
2C
2D
2E
2F
30 to 47
48
49
4A to 4C
4D
4E to 51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60 to 61
62
63
64
65
66 to 74
75
76 to 89
8A
8B
10
10
80
80
80
EB
D5
20
20
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Pre-white balance data input
Fixed data-1
Offset adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Color reproduction adj. (ND filter 1)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
10
10
80
80
80
EB
D5
20
20
Address
Remark
Initial value
NTSC PAL
Address
Remark
Initial value
NTSC PAL
6-15
DCR-VX2100/VX2100E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENT” are
satisfied.
1. 27MHz Origin Oscillation Adjustment
(VC-358 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin rj of IC771 or pin qf of IC706
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
1C
Specified Value
f=13500000 
±
 68Hz
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
1C
Change the data and set the
frequency (f) to the specified
value.
3
F
1C
Press PAUSE button.
4
0
01
00
Set the data.
2. Zoom Key Center Adjustment
Set the A/D value center of the microprocessor to the center voltage
of the zoom key.
If deviated, the zoom lens operates of itself ,even if the zoom key is
the center position.
Subject
Not required
Measurement Point
Display data of page: 6, address: 50
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
5D
Note: Don’t touch the zoom switch during adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
50
Read the data, and this data is
named D
50
.
3
F
5D
D
50
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
VC-358 board
IC771
IC706
100
76
26
25
12
13
24
48
37
1
1
51
75
50
Fig. 6-1-6.
6-16
DCR-VX2100/VX2100E
3. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E, 1F, 70
Specified Value 1
88 to 8C
Specified Value 2
15 to 19
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
8A
Set the data.
3
6
95
17
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note3)
6
6
01
00
Set the data, and press PAUSE
button.
Note3: The adjustment data will be automatically input to page: F, address:
1E, 1F, 70.
Checking method:
Order Page Address Data
Procedure
1
6
04
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
04
00
Set the data.
3
6
94
00
Set the data.
4
6
95
00
Set the data.
5
0
01
00
Set the data.
4. Offset Adjustment
Adjust so that the AGC OUT potential lies within the specified value
of the digital clamp.
Subject
Not required
Measurement Point
DDS display data of LCD or TV
monitor (Note1)
Measuring Instrument
Adjustment Page
E
Adjustment Address
2D, 2E, 2F
Specified Value
70 to 90
Note 1: DDS display data of LCD or TV monitor.
CA 00 0000
CA 00 00XX
Object data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
11
02
Set the data, and press PAUSE
button.
3
6
01
05
Set the data, and press PAUSE
button.
4
E
0C
02
Set the data, and press PAUSE
button.
5
6
04
1F
Set the data.
6
E
2D
Change the data and adjust the
DDS display data (Note 1) to
“80”. (Rch offset adjustment)
7
E
2D
Press PAUSE button.
8
6
04
20
Set the data.
9
E
2E
Change the data and adjust the
DDS display data (Note 1) to
“80”. (Gch offset adjustment)
10
E
2E
Press PAUSE button.
11
6
04
21
Set the data.
12
E
2F
Change the data and adjust the
DDS display data (Note 1) to
“80”. (Bch offset adjustment)
13
E
2F
Press PAUSE button.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
D
11
00
Set the data, and press PAUSE
button.
2
E
0C
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
6
01
00
Set the data, and press PAUSE
button.
5
6
04
00
Set the data.
6
Turn off the power and turn on
again.
6-17
DCR-VX2100/VX2100E
5. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note2)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
24 to 2B, 36 to 3D, 5D
Note1: Dark Siemens star chart.
Note2: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
ND FILTER ...................................................................... OFF
(The data of page: 6, address: 9D is “00”.)
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note: The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the protection glass of the camcorder is less than
3cm. (Remove the lens hood.)
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage:
The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button. (Note3)
3
6
01
27
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note4)
5
F
2A
Check that the data is “00” to
“07”.
Note3: Don’t touch the zoom switch. If you touch the zoom switch, the
zoom center adjustment data will be rewritten in the value which
isn’t correct.
Note4: The adjustment data will be automatically input to page: F, address::
24 to 2B, 36 to 3D, 5D.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
02
00
Set the data.
3
0
01
00
Set the data.
4
Turn off the power and turn on
again.
5
Perform “Flange Back Check”.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
Fig. 6-1-7.
Page of 66
Display