Sony DCR-TRV5 / DCR-TRV5E Service Manual ▷ View online

5-42
5. AEQ Adjustment (VC-207 Board)
Mode
Camera recording /playback
(LP mode)
Subject
Arbitrary
Signal
Playback signal of recorded tape
Measurement Point
CH1: Pin 8 of CN005
(RF MONITOR)
CH2: Pin 6 of CN005 (JSWP)
Measuring Instrument
Oscilloscope
Trigger source: CH2
Adjustment Page
C
Adjustment Address
40, 41, 42, 43
Note:
Connect a 75 
Ω 
resister between Pin 8 (RF MONITOR) and Pin
4 (GND) of CN005.
75 
Ω 
resister (Parts code: 1-247-804-11)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Write the following data in page: C, addresses: 40 to 43, 4B,
5A.
(To write the data, press the PAUSE button of the adjustment
remote commander each time data is set.)
Page: C, address: 40, data: C0
Page: C, address: 41, data: C0
Page: C, address: 42, data: 90
Page: C, address: 43, data: 90
Page: C, address: 4B, data: 80
Page: C, address: 5A, data: 00
3)
Record for two minutes from tape top.
4)
Rewind the tape, and play back from the tape top.
5)
When the RF output stabilizes, select page: 3, address: 01, set
data: 07, and press the PAUSE button of the adjustment remote
commander.
6)
About 20 to 30 seconds after pressing the PAUSE button, check
that the data of page: 3, address: 02 changes from “07” to “00”.
7)
Check that the data of page: 3, address: 03 is following value.
When “00” : Normal
When “01” : EVENch is faulty
When “02” : ODDch is faulty
When “03” : EVENch and ODDch are faulty
Perform the following procedure only when “00” is displayed.
8)
Read the data of page: 3, address: 04 to 07, and take the values
as D
04
, D
05
, D
06
 and D
07
.
9)
Select page: C, address: 40, set data: D
04
, and press the PAUSE
button of the adjustment remote commander.
10) Select page: C, address: 42, set data: D
05
, and press the PAUSE
button.
11) Select page: C, address: 41, set data: D
06
, and press the PAUSE
button.
12) Select page: C, address: 43, set data: D
07
, and press the PAUSE
button.
13) Select page: C, address: 4B, set data: 00, and press the PAUSE
button.
14) Select page: C, address: 5A, set data: 8C, and press the PAUSE
button.
15) Select page: 0, address: 01, and set data: 00.
6. PLL Capture Range Adjustment (VC-207 Board)
Mode
Camera recording /playback
(LP mode)
Subject
Arbitrary
Signal
Playback signal of recorded tape
Measurement Point
CH1: CL042 (Pin
203
 of IC1701)
     (C1ERP)
CH2: Pin 6 of CN005 (JSWP)
Measuring Instrument
Oscilloscope
Trigger source: CH2
Adjustment Page
C
Adjustment Address
46
Adjusting method:
1)
Record for two minutes on any tape.
2)
Select page: 0, address: 01, and set data: 01.
3)
Write the following data in page: C, address: 4B and 5A.
(To write the data, press the PAUSE button of the adjustment
remote commander each time data is set.)
Page: C, address: 4B, data: 80
Page: C, address: 5A, data: 00
4)
Playback the recorded portion.
5)
Select page: C, address: 46, set data: 80, and press the PAUSE
button of the adjustment remote commander.
6)
Set the data of page: C, address: 46 to “60”, and check that the
pulse is not set at the audio area head of the C1ERP waveform's
ODDch of the oscilloscope (CH1).
7)
Set the data of page: C, address: 46 to “A0”, and check that the
pulse is not set at the audio area head of the C1ERP waveform's
ODDch of the oscilloscope (CH1). After confirming steps 6)
and 7), set the data of page: C, address: 46 to “80”, and proceed
to step 12).
8)
If the pulse is set in steps 6) and 7), increase the data of page:
C, address: 46 from “80“, and read the data D
1
 when the pulse
is set at the audio area head of CH1.
9)
Decrease the data of page: C, address: 46 from “80“, and read
the data D
2
 when the pulse is set at the audio area head of CH1.
10) Obtain the average value of D
1
 and D
2
 , and take it as D
3
.
11) Select page: C, address: 46, set data: D
3
, and press the PAUSE
button of the adjustment remote commander.
12) Select page: C, address: 4B, set data: 00, and press the PAUSE
button.
13) Select page: C, address: 5A, set data: 8C, and press the PAUSE
button.
14) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-7
CH1
CH2
CH1
CH2
ODD ch
3.33msec
Pulse is not set at the audio area head.
When the pulse is set at the audio area head.
ODD ch
5-43
3-5-2.
Clock Adjustments
1. IC1900 27MHz XTAL f
0
 Adjustment (VC-207 Board)
Set the sub-carrier frequency of the video output signal in the VTR
mode.
Mode
VTR stop
Signal
No signal
Measurement Point
R1901 (Pin 2 of IC1900) or Pin 8
of IC 1104
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
98
Specified Value
R1901:
f = 13500000 ± 68 Hz
Pin 8 of IC1104:
f = 6750000 ± 34 Hz
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 98, change the data and set the clock
frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
2. IC1900 VCO Operation Check (VC-207 Board)
Mode
VTR stop
Signal
No signal
Measurement Point
Display data of page: 2, address: 0E
Measuring Instrument
Adjustment remote commander
Specified Value
“C0” to “FF”
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 05, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: D, address: B0, set data: 03, and press the PAUSE
button.
4)
Select page: 2, address: 0E, and check that the data is “C0” to
“FF”.
5)
Select page: D, address: B0, set data: 05, and press the PAUSE
button.
6)
Select page: 2, address: 0E, and check that the data is “C0” to
“FF”.
7)
Select page: D, address: B0, set data: 00, and press the PAUSE
button.
8)
Select page: 2, address: 05, set data: 00, and press the PAUSE
button.
9)
Select page: 0, address: 01, and set data: 00.
3. IC6101 41.85MHz VCO Operation Check
(VC-207 Board)
Mode
Camera recording
Subject
Arbitrary
Measurement Point
Display data of page: 3, address: 39
Measuring Instrument
Adjustment remote commander
Specified Value
“37” to “C9”
Checking method:
1)
Select page: 3, address: 39, and check that the data is “37” to
“C9”.
5-44
3-5-3.
Base Band Block Adjustments
1. Composite Output Y Level Adjustment
(VC-207 Board)
Set the Y signal level of the composite video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Video signal terminal of AUDIO/
VIDEO jack (75 
Ω 
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
96
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
Note:
Insert a plug in the AUDIO/VIDEO jack.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 96, change the data and set the sync
signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Perform “Composite Output Chroma Level Adjustment”.
Fig. 5-3-8
A
H
2. Composite Output Chroma Level Adjustment
(VC-207 Board)
Set the chroma signal level of the composite video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Video signal terminal of AUDIO/
VIDEO jack (75 
Ω 
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
97
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
Note 1:
Insert a plug in the AUDIO/VIDEO jack.
Note 2:
Perform “Composite Output Y Level Adjustment” before this
adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 97, change the data and set the burst
signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Perform “S-C Output Level Adjustment”.
Fig. 5-3-9
A
H
5-45
3. S-C Output Level Adjustment (VC-207 Board)
Set the chroma signal level of the S video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
jack (75 
Ω 
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
94
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
Note 1:
Insert a plug in the S VIDEO jack.
Note 2:
Perform “Composite Output Y Level Adjustment” and “Composite
Output Chroma Level Adjustment” before this adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 94, change the data and set the burst
signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-10
A
H
4. S-Y Output Level Adjustment (VC-207 Board)
Set the Y signal level of the S video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Y signal terminal of S VIDEO jack
(75 
Ω 
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
95
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
Note:
Insert a plug in the S VIDEO jack.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 95, change the data and set the sync
signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-11