5-38
3-3. SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Battery End Adjustment (VC-207 board)
Set the battery end voltage.
If the voltage is incorrect, the life of the battery will shorten.
The image at the battery end will also be rough.
Mode
Camera recording
Subject
Arbitrary
Measurement Point
LCD display of the adjusting remote
Measuring Instrument
commander
Adjustment Page
D
Adjustment Address
28 to 2C, 37
Note:
The lens block and cabinet (R) must be connected.
1) AUTO FOCUS ·································· OFF
2) LCD screen ········································ Closed
Connection:
1)
Connect the regulated power supply to the battery terminal and
connect the digital voltmeter to CN801 of DD-110 board as
shown in Fig. 5-3-3.
Fig. 5-3-3
Adjusting method:
1)
Adjust the output voltage of the regulated power supply so
that the digital voltmeter display is 6.1 ± 0.1Vdc.
2)
Turn off the power supply.
3)
Set the HOLD switch of the adjustment remote commander to
ON (SERVICE position).
4)
Turn on the power supply.
5)
Load a cassette, and set to the camera recording mode.
6)
Select page: 0, address: 01, and set data: 01.
7)
Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 5.30 ± 0.01Vdc.
8)
Select page: 2, address: 51, read the data, and this data is named
Dref.
9)
Select page: D, address: 28, set data: Dref, and press the PAUSE
button of the adjustment remote commander.
10) Select page: D, address: 37, set data: Dref, and press the PAUSE
button
11) Convert Dref to decimal notation, and obtain Dref’. (Refer to
Table 5-4-1. “Hexadecimal-decimal conversion table” of “5-
4. Service mode”)
12) Calculate D
29
', D
2A
’, D
2B
’ and D
2C
’ using following equations
(decimal calculation), convert it to a hexadecimal number, and
input each adjustment address.
Address: 29
D
29
' = Dref’+11
Address: 2A
D
2A
’ = Dref’+36
Address: 2B
D
2B
’ = Dref’+58
Address: 2C
D
2C
’ = Dref’+66
Note:
After setting each data, be sure to press the PAUSE button.
13) Select page: 0, address: 01, and set data: 00.
1
3
Digital voltmeter
Regulated power supply
5.30 
±
 0.01V
DD-110 board
CN801
J-6082-223-A
5-39
3-4. SERVO SYSTEM ADJUSTMENTS
1. T Reel FG Duty Adjustment and CSerr Adjustment
    (VC-207 Board)
Adjusting Method:
1)
Set the power switch to VTR (or PLAYER).
2)
Close the cassette compartment without inserting the cassette.
3)
Connect the adjustment remote commander, and set the HOLD
switch to ON (SERVICE position).
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: C, address: 6A, set data: 10, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 3, address: 09, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 3, address: 01, set data: 1A, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 3, address: 02, and check that the data is changed
from “17” to “00”.
9)
Set the HOLD switch of the adjustment remote commander to
OFF, and wait more than 2 seconds.
10) Set the HOLD switch of the adjustment remote commander to
ON.
11) Check that the data of page: 3, address: 08 and that of page: C,
address: 59 are the same.
12) Select page: 3, address: 03. If the data is “00”, it means that the
CSerr adjustment has ended normally.
13) Check that the data of page: 3, address: 04 and that of page: C,
address: 6F are the same.
14) Select page: C, address: 6F. If the data is “01”, or “02”, “03”, it
means that the T reel FG adjustment has ended normally.
15) Select page: C, address: 6A, set data: 00, and press the PAUSE
button of the adjustment remote commander.
16) Set the data of page: 0, address: 01, and set data: 00.
17) Turn OFF the power supply.
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjustment remote commander
display data
C
59, 6F
T reel FG Duty Adjustment:
The data of page: C, address: 6F is
“01”, or “02” , “03”.
CSerr Adjustment:
The data of page: 3, address: 03 is
“00”.
2. Switching Position Adjustment (VC-207 Board)
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
 Adjusting Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 0E, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 02, and check that the data is changed
from “0E” to “00”.
4)
Select page: 3, address: 03, and check that the data is “00”.
5)
Set the HOLD switch of the adjustment remote commander to
OFF, and wait more than 2 seconds (so that the adjustment
data is automatically written in page: C, address: 4C to 4F).
6)
Set the HOLD switch of the adjustment remote commander to
ON.
7)
Select page: 0, address: 01, and set data: 00.
8)
Set to the stop mode.
9)
Turn OFF the power supply.
VTR Playback
SW/OL reference tape (XH2-3)
Display data of page: 3, address: 03
Adjustment remote commander
C
4C, 4D, 4E, 4F
The data of page: 3, address: 03 is
“00”.
5-40
3-5.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the
specified value of “36 MHz Origin Oscillation Adjustment” and
“GUM PLL Adjustment” of “CAMERA SYSTEM
ADJUSTMENT” is satisfied.
3-5-1.
RF Block Adjustments
1. Recording Current Adjustment (VC-207 Board)
Mode
VTR stop
Measurement Point
ODDch adjustment
CH1: Pin 6 of CN2701 (CL2718)
CH2: Pin 5 of CN2701 (CL2719)
EVENch adjustment
CH1: Pin 2 of CN2701 (CL2722)
CH2: Pin 3 of CN2701 (CL2721)
Measuring Instrument
Oscilloscope
ADD mode
CH2 INV mode
Adjustment Page
C
Adjustment Address
3E, 3F
Specified Value
A = 3.1 ± 0.1 Vp-p
Connection:
Disconnect CN2701 and connect as follows.
1)
ODDch adjustment: Connect a 180 
 resistor between Pin 6
of CN2701 (CL2718) and Pin 5 of CN2701 (CL2719).
2)
EVENch adjustment: Connect a 180 
 resistor between Pin
2 of CN2701 (CL2722) and Pin 3 of CN2701 (CL2721).
180 
Ω 
resistor (Parts code: 1-249-408-11)
Adjusting method:
1)
Equalize the vertical range of CH1 and CH2 of the oscilloscope.
2)
Set the oscilloscope to the ADD mode, and set CH2 to the INV
mode.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: 3, address: 01, set data: 0C, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 3, address: 34, and set data: 01.
6)
Select page: C, address: 3F (ODDch adjustment) or address:
3E (EVENch adjustment), change the data and adjust the signal
voltage (A) to the specified value.
7)
Press the PAUSE button of the adjustment remote commander.
8)
Select page: 3, address: 34, and set data: 04.
9)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
10) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-4
A
0.1 
µ
sec
2. PLL f
0
 Adjustment (VC-207 Board)
Mode
VTR stop
Measurement Point
Display data of page: 3, address: 04
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
3C, 3D
Specified Value
Displayed data is “FD” to “FF” or
“00” to “03”. (“FF”, “00” are center
values)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 3, address: 01, set data: 05, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 36, and set data: 04.
4)
Select page: 3, address: 04, and check that the average value
D
04
 of the displayed data is “FD” to “FF” or “00” to  “03”. If
outside this range, change the data of page: C, address: 3C,
and check again.
[ If D
04
 is “80” to “FC” ]
Decrease the data of page: C, address: 3C. (As the data is to be
rewritten, press the PAUSE button of the adjustment remote
commander.)
[ If D
04
 is “04” to “7F” ]
Increase the data of page: C, address: 3C. (As the data is to be
rewritten, press the PAUSE button of the adjustment remote
commander.)
5)
Select page: 3, address: 36, and set data: 05.
6)
Select page: 3, address: 04, and check that the average value
D
04
 of the displayed data is “FD” to “FF” or “00” to  “03”. If
outside this range, change the data of page: C, address: 3D,
and check again.
[ If D
04
 is “80” to “FC” ]
Decrease the data of page: C, address: 3D. (As the data is to be
rewritten, press the PAUSE button of the adjustment remote
commander.)
[ If D
04
 is “04” to “7F” ]
Increase the data of page: C, address: 3D. (As the data is to be
rewritten, press the PAUSE button of the adjustment remote
commander.)
7)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 3, address: 36, and set data: 02.
9)
Select page: 0, address: 01, and set data: 00.
5-41
3. CLK DELAY Adjustment (VC-207 Board)
Mode
Camera recording /playback
(LP mode)
Subject
Arbitrary
Signal
Playback signal of recorded tape
Measurement Point
CH1: CL042 (Pin
203
 of IC1701)
     (C1ERP)
CH2: Pin 6 of CN005 (JSWP)
Measuring Instrument
Oscilloscope
Trigger source: CH2
Adjustment Page
C
Adjustment Address
47
Adjusting method:
1)
Record for two minutes on any tape.
2)
Select page: 0, address: 01, and set data: 01.
3)
Write the following data in page: C, addresses: 40 to 44, 47,
4B, 5A.
(To write the data, press the PAUSE button of the adjustment
remote commander each time data is set.)
Page: C, address: 40, data: C0
Page: C, address: 41, data: C0
Page: C, address: 42, data: 90
Page: C, address: 43, data: 90
Page: C, address: 44, data: 90
Page: C, address: 47, data: C0
Page: C, address: 4B, data: 80
Page: C, address: 5A, data: 00
4)
Playback the recorded portion.
5)
Increase the data of page: C, address: 47 from “C0”, and read
the data D
1
 when the CH1 pulse is set to the whole audio and
video areas.
6)
Decrease the data of page: C, address: 47 from “C0”, and read
the data D
2
 when the CH1 pulse is set to the whole audio and
video areas.
7)
Obtain the average value of D
1
 and D
2
 , and take it as D
3
.
8)
Select page: C, address: 47, set data: D
3
, and press the PAUSE
button of the adjustment remote commander.
9)
Select page: C, address: 4B, set data: 00, and press the PAUSE
button.
10) Select page: C, address: 5A, set data: 8C, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
12) After completing the adjusting, perform “5. AEQ Adjustment”.
Fig. 5-3-5
CH1
CH2
CH1
CH2
EVEN ch
EVEN ch
3.33msec
When the CH1 pulse is not set.
When the CH1 pulse is set.
4. AGC Center Level Adjustment (VC-207 Board)
Mode
Camera recording /playback
(LP mode)
Subject
Arbitrary
Signal
Playback signal of recorded tape
Measurement Point
CH1: CL042 (Pin
203
 of IC1701)
     (C1ERP)
CH2: Pin 6 of CN005 (JSWP)
Measuring Instrument
Oscilloscope
Trigger source: CH2
Adjustment Page
C
Adjustment Address
44
Adjusting method:
1)
Record for two minutes on any tape.
2)
Select page: 0, address: 01, and set data: 01.
3)
Write the following data in page: C, addresses: 40 to 44, 4B,
5A.
(To write the data, press the PAUSE button of the adjustment
remote commander each time data is set.)
Page: C, address: 40, data: C0
Page: C, address: 41, data: C0
Page: C, address: 42, data: 90
Page: C, address: 43, data: 90
Page: C, address: 44, data: 90
Page: C, address: 4B, data: 80
Page: C, address: 5A, data: 00
4)
Playback the recorded portion.
5)
Increase the data of page: C, address: 44 from “90”, and read
the data D
1
 when the CH1 pulse is set to the whole audio and
video areas.
6)
Decrease the data of page: C, address: 44 from “90”, and read
the data D
2
 when the CH1 pulse is set to the whole audio and
video areas.
7)
Obtain the average value of D
1
 and D
2
 , and take it as D
3
.
8)
Select page: C, address: 44, set data: D
3
, and press the PAUSE
button of the adjustment remote commander.
9)
Select page: C, address: 4B, set data: 00, and press the PAUSE
button.
10) Select page: C, address: 5A, set data: 8C, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
12) After completing the adjusting, perform “5. AEQ Adjustment”.
Fig. 5-3-6
CH1
CH2
CH1
CH2
EVEN ch
EVEN ch
3.33msec
When the CH1 pulse is not set.
When the CH1 pulse is set.