DOWNLOAD Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man3) Service Manual ↓ Size: 3.76 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV360 DCR-TRV361 DCR-TRV460 DCR-TRV460E DCR-TRV461E (serv.man3)
Pages
127
Size
3.76 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 1
File
dcr-trv360-dcr-trv361-dcr-trv460-dcr-trv460e-dcr-t.pdf
Date

Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man3) Service Manual ▷ View online

Getting started
D:\##SAGYO\DTP-shanhai-agari\824719S DCRTRV360-US\824719S DCR-TRV360_US\824719S DCR-
TRV360_US\3087921111 DCR-TRV360\01GB03PRE.fm
master:Right
Ge
tt
in
g
 sta
rte
d
13
DCR-TRV360/TRV361/TRV460
3-087-921-11(1)
Getting started
Step 1: Checking 
supplied items
Make sure you have following items supplied 
with your camcorder.
The number in parentheses indicates the number 
of that item supplied.
“Memory Stick” 8MB (1)
(DCR-TRV361)
Memory Stick media is only supplied with 
DCR-TRV361.
There is no Memory Stick media supplied with 
DCR-TRV360/TRV460.
AC Adaptor (1)
Power cord (1)
Lens cap (1)
See page 126 on how to attach the lens cap.
Shoulder strap (1)
See page 127 on how to attach the shoulder 
strap.
Wireless Remote Commander (1)
A button-type lithium battery is already 
installed.
A/V connecting cable (1)
USB cable (1)
Rechargeable battery pack NP-FM30 (1)
CD-ROM “SPVD-012 USB Driver” (1)
Camera Operations Guide 
(This manual) (1)
Computer Applications Guide (1)
Getting started
14
DCR-TRV360/TRV361/TRV460
3-087-921-11(1)
D:\##SAGYO\DTP-shanhai-agari\824719S DCRTRV360-US\824719S DCR-TRV360_US\824719S DCR-
TRV360_US\3087921111 DCR-TRV360\01GB03PRE.fm
master:Right
Step 2: Charging the 
battery pack 
You can charge the battery by attaching the 
“InfoLITHIUM” battery pack (M series) 
to your camcorder.
b
Notes
• You cannot use batteries other than the 
“InfoLITHIUM” battery pack (M series) (p. 118).
• Do not short-circuit the DC plug of the AC Adaptor 
or battery terminals with any metallic objects. This 
may cause a malfunction.
• Use a nearby wall outlet when using the AC 
Adaptor. Disconnect the AC Adaptor from the wall 
outlet immediately if any malfunction occurs.
1
Lift up the viewfinder.
2
Attach the battery pack by sliding it in 
the direction of the arrow until it 
clicks.
3
With the v mark on the DC plug 
facing up, connect the AC Adaptor to 
the DC IN jack on your camcorder. 
4
Connect the power cord to the AC 
Adaptor.
5
Connect the power cord to the wall 
outlet.
To the wall outlet
DC plug
DC IN jack
Power cord
AC Adaptor
Battery pack
mark
Getting started
D:\##SAGYO\DTP-shanhai-agari\824719S DCRTRV360-US\824719S DCR-TRV360_US\824719S DCR-
TRV360_US\3087921111 DCR-TRV360\01GB03PRE.fm
master:Right
Ge
tt
in
g
 sta
rte
d
15
DCR-TRV360/TRV361/TRV460
3-087-921-11(1)
6
Slide the POWER switch up to (CHG) 
OFF.
The CHG (charge) lamp lights up and 
charging starts.
After charging the battery
The CHG (charge) lamp turns off when the 
battery is fully charged. Disconnect the AC 
Adaptor from the DC IN jack. 
To remove the battery pack
1
Set the POWER switch to (CHG) OFF.
2
Lift up the viewfinder.
3
Slide the battery pack out in the direction 
of the arrow pressing the BATT (battery) 
release button down.
b
Note
• If you do not use the battery pack for a long time, use 
up the battery pack completely before storing it. See 
page 119 a
bout storage of the battery pack.
To check the remaining battery – Battery 
Info
You can check the battery’s current charge level 
and its current remaining recording time both 
during charging or when the power is turned off.
1
Set the POWER switch to (CHG) OFF.
2
Press OPEN and open the LCD panel.
3
Press DSPL/BATT INFO.
The battery information appears for about 7 
seconds. 
Keep the button pressed to view it for about 
20 seconds.
Battery charge level: Displays 
approximate remaining amount of 
power left in the battery pack.
Approximate possible recording time 
using the LCD panel.
Approximate possible recording time 
using the viewfinder.
BATT(battery) 
release button
POWER switch
POWER switch
OPEN
DSPL/BATT INFO
BATTERY INFO
50%
0%
100%
BATTERY CHARGE LEVEL
REC TIME AVAILABLE
LCD SCREEN
VIEWFINDER
:
:
72 min
95 min
,
continued
Getting started
16
DCR-TRV360/TRV361/TRV460
3-087-921-11(1)
D:\##SAGYO\DTP-shanhai-agari\824719S DCRTRV360-US\824719S DCR-TRV360_US\824719S DCR-
TRV360_US\3087921111 DCR-TRV360\01GB03PRE.fm
master:Right
Charging time
Approximate number of minutes required when 
you fully charge a fully discharged battery pack 
at 25°C (77°F). (10 – 30°C (50 – 86°F) 
recommended.)
Recording time when recording with the 
LCD screen on
Approximate number of minutes available 
when you use a fully charged battery pack at 
25°C (77°F).
Recording time when recording with the 
viewfinder 
Approximate number of minutes available 
when you use a fully charged battery pack at 
25°C (77°F).
* Approximate number of minutes when recording 
while you repeatedly record, start/stop, slide the 
POWER switch to change the power mode, and 
zoom. The actual battery life may be shorter.
Playing time
Approximate number of minutes available 
when you use a fully charged battery pack at 
25°C (77°F).
This table shows the playing time for tapes 
recorded in the Digital8 
 system.
For DCR-TRV460:
The playing time of tapes recorded on other 
devices in the Hi8 
/standard 8 mm 
 
system is reduced by about 20%.
b
Notes
• The power will not be supplied from the battery pack 
when the AC Adaptor is connected to the DC IN jack 
of your camcorder, even if its power cord is 
disconnected from the wall outlet.
• The recording and playback time will be shorter 
when you use your camcorder in low temperature.
• The CHG (charge) lamp flashes during charging, or 
the battery information will not be correctly 
displayed in following conditions.
– The battery pack is not attached correctly.
– The battery pack is damaged.
– The battery pack is fully discharged. (For Battery 
information only.)
Battery pack
NP-FM30 (supplied)
145
NP-FM50
150
NP-QM71/QM71D
260
NP-QM91/QM91D
360
Battery pack Continuous 
recording 
time
Typical* 
recording 
time 
NP-FM30 
(supplied)
80
40
NP-FM50
130
60
NP-QM71/
QM71D
315
150
NP-QM91/
QM91D
475
230
Battery pack Continuous 
recording 
time
Typical* 
recording 
time
NP-FM30 
(supplied)
105
50
NP-FM50
170
85
NP-QM71/
QM71D
415
205
NP-QM91/
QM91D
625
310
Battery pack LCD panel 
opened
LCD panel 
closed
NP-FM30 
(supplied)
80
120
NP-FM50
135
195
NP-QM71/
QM71D
335
465
NP-QM91/
QM91D
505
695
Page of 127
Display

Click on the first or last page to see other DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man3) service manuals if exist.