DOWNLOAD Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man2) Service Manual ↓ Size: 5.27 MB | Pages: 62 in PDF or view online for FREE

Model
DCR-TRV360 DCR-TRV361 DCR-TRV460 DCR-TRV460E DCR-TRV461E (serv.man2)
Pages
62
Size
5.27 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv360-dcr-trv361-dcr-trv460-dcr-trv460e-dcr-t.pdf
Date

Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man2) Service Manual ▷ View online

1-1
SECTION  1
SERVICE  NOTE
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
1-1. NOTE  FOR  REPAIR
Make sure that the flat cable and flexible board are not cracked of
bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
Cut and remove the part of gilt 
which comes off at the point.
(Be careful or some 
pieces of gilt may be left inside) 
When remove a connector, don’t pull at wire of connector.
It is possible that a wire is snapped.
When installing a connector, don’t press down at wire of connector.
It is possible that a wire is snapped.
1-2. POWER  SUPPLY  DURING  REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so
that the unit cannot operate.
The following method is available to prevent this.
Method 1.
Use the AC power adaptor (AC-L10, AC-VQ800 etc.).
1-2
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
1-3. TO  TAKE  OUT  A  CASSETTE  WHEN  NOT  EJECT (FORCE  EJECT)
1
Refer to “SECTION 2 DISASSEMBLY” to remove the mechanism deck block.
2
Disconnect CN2401 (2P) of VC-345 board.
3
Add +5V from the DC POWER SUPPLY and unload with a pressing the cassette compartment.
4
Pull the timing belt in the direction of 
arrow 
A
 with a pincette while pressing 
the cassette compartment (take care 
not to damage) to adjust the bending 
of a tape.
5
Let go your hold the cassette 
compartment and rise the cassette 
compartment to take out a cassette.
Pincette
Timing belt
Timing belt
Press the cassette compartment not to 
rise the cassette compartment
[DC power supply]
(+5V)
Adjust the bending of a tape
Disconnect CN2401
of VC-345 board.
Loading motor
A
A
1-3
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
1-4. SELF-DIAGNOSIS  FUNCTION
1-4-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder or LCD what
to do. This function consists of two display; self-diagnosis display
and service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
1-4-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
viewfinder or LCD shows a 4-digit display consisting of an alphabet
and numbers, which blinks at 3.2 Hz. This 5-character display
indicates the “repaired by:”, “block” in which the problem occurred,
and “detailed code” of the problem.
1 1
3 1
C : 3 1 : 11
C
Repaired by:
Refer to  1-4-3. Self-diagnosis Code Table .
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder
Display window
C : 3 1 : 1 1
1-4
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
1-4-3. Self-diagnosis Code Table
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
Block
Function
0
4
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
Detailed
Code
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
3
0
3
1
4
0
4
1
4
2
4
3
4
4
1
0
1
1
2
0
2
1
2
2
2
3
3
0
3
1
4
0
4
1
4
2
4
3
4
4
Symptom/State
Non-standard battery is used.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
S reel side tape slacking when unloading.
T reel fault.
S reel fault.
FG fault when starting capstan.
FG fault during normal capstan operations.
FG fault when starting drum.
PG fault when starting drum.
FG fault during normal drum operations.
PG fault during normal drum operations.
Phase fault during normal drum operations.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
S reel side tape slacking when
unloading.
T reel fault.
S reel fault.
FG fault when starting capstan.
FG fault during normal capstan
operations.
FG fault when starting drum.
PG fault when starting drum.
FG fault during normal drum
operations.
PG fault during normal drum
operations.
Phase fault during normal drum
operations.
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Page of 62
Display