Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv33-dcr-trv33e-sm4.pdf
Date

Sony DCR-TRV33 / DCR-TRV33E (serv.man4) Service Manual ▷ View online

6-34
DCR-TRV33/TRV33E
4. White Balance Adjustment (VA-118 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
Camera
Subject
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
3C, 3D
Specified Value
The EVF screen should not be colored.
Note1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC4201
Note2:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
3C
9E
Set the data, and press PAUSE
button.
3
C
3D
74
Set the data, and press PAUSE
button.
4
C
3D
Check that the EVF screen is not
colored. If not colored, proceed to
step 10.
5
C
3C
Change the data so that the EVF
screen is not colored.
6
C
3C
Press PAUSE button.
7
C
3D
Change the data so that the EVF
screen is not colored.
8
C
3D
Press PAUSE button.
9
C
3D
If the EVF screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
6-35
DCR-TRV33/TRV33E
1-5.
LCD SYSTEM ADJUSTMENT
Note1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note3:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note4:
NTSC model: DCR-TRV33
PAL model: DCR-TRV33E
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN1004 of the VC-313 board. Connect the
measuring instruments via the multi CPC-7 jig (J-6082-382-A). The
following table shows the Pin No. and signal name of CN1004.
Table 6-1-15.
1. VCO Adjustment (PD-188 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 7 of CN1004 of VC-313 board
(H START)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
47, 48
Specified Value
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
47
Change the data and set the VCO
frequency (f) to the specified
value.
3
C
47
Press PAUSE button.
4
C
47
Read the data, and this data is
named D
47
.
5
Convert D
47
 to decimal notation,
and obtain D
47
’. (Note2)
6
Calculate D
48
’ using following
equations (Decimal calculation)
[NTSC model]
When D
47
’   229
D
48
’ = D
47
’ + 26
When D
47
’ > 229
D
48
’ = 255
[PAL model]
When D
47
’   26
D
48
’ = D
47
’ – 26
When D
47
’ < 26
D
48
’ = 0
7
Convert D
48
’ to a hexadecimal
number, and obtain D
48
. (Note2)
8
C
48
D
48
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2:
Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
FRRV
RF MON
RF IN/LANC
JACK IN
SWP
PANEL COM
GND
H START
GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
PANEL VG
GND
EVF VCO
GND
EVF VG
EXT DA
LANC SIG
N.C.
COVER
COVER
CN1004
Remove the CPC lid
16
1
Fig. 6-1-18.
6-36
DCR-TRV33/TRV33E
2. PSIG GRAY Adjustment (PD-188 board)
Set the PSIG signal level to an appropriate level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 5 of CN1004 of VC-313 board
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
4C
Specified Value
A = 5.00 ± 0.10V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
4C
Change the data and set the PSIG
signal level (A) to the specified
value. (The data should be “00”
to “7F”.)
3
C
4C
Press PAUSE button.
4
0
01
00
Set the data.
3. RGB AMP Adjustment (PD-188 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 9 of CN1004 of VC-313 board
(PANEL VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
4A
Specified Value
A = 7.58 ± 0.05V (NTSC)
A = 7.46 ± 0.05V (PAL)
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
4A
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to the
specified value.
3
C
4A
Press PAUSE button.
4
0
01
00
Set the data.
Fig. 6-1-18.
Pedestal
Pedestal
A
2H
Fig. 6-1-17.
A
2H
6-37
DCR-TRV33/TRV33E
4. Black Limit Adjustment (PD-188 board)
Set the video signal level for driving the LCD driver to an appropriate
level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 5 of CN1004 of VC-313 board
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
4B
Specified Value
A = 8.30 ± 0.08V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
C4
61
Set the data.
3
3
C5
Set the following data.
5B (NTSC), 53 (PAL)
4
C
4B
Change the data and set the PSIG
signal amplitude (A) to the
specified value. (The data should
be “00” to “0F”)
5
C
4B
Press PAUSE button.
6
3
C4
00
Set the data.
7
3
C5
00
Set the data.
8
0
01
00
Set the data.
9
Check that the specified value of
“RGB AMP Adjustment” is
satisfied. If not, perform “RGB
AMP Adjustment”.
5. Contrast Adjustment (PD-188 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 9 of CN1004 of VC-313 board
(PANEL VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
4F
Specified Value
A = 2.54 ± 0.05V (NTSC)
A = 2.58 ± 0.05V (PAL)
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
4F
Change the data and set the
voltage (A) between the 100 IRE
and 0 IRE (pedestal) to the
specified value. (The data should
be “00” to “7F”.)
3
C
4F
Press PAUSE button.
4
0
01
00
Set the data.
Fig. 6-1-19.
A
V
Fig. 6-1-20.
100 IRE
Pedestal
A
2H