DOWNLOAD Sony DCR-TRV255E / DCR-TRV260 / DCR-TRV265 / DCR-TRV265E (serv.man3) Service Manual ↓ Size: 1.67 MB | Pages: 56 in PDF or view online for FREE

Model
DCR-TRV255E DCR-TRV260 DCR-TRV265 DCR-TRV265E (serv.man3)
Pages
56
Size
1.67 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv255e-dcr-trv260-dcr-trv265-dcr-trv265e-sm3.pdf
Date

Sony DCR-TRV255E / DCR-TRV260 / DCR-TRV265 / DCR-TRV265E (serv.man3) Service Manual ▷ View online

DCR-TRV255E/TRV260/TRV265/TRV265E
6-11
4.
C Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
10
EE
EE
Switching position adj.
11
00
00
12
00
00
13
00
00
14, 15
Fixed data-1 (Initialized data)
16
E0
E0
CAP FG/REEL FG duty adj.
17
E0
E0
18 to 24
Fixed data-1 (Initialized data)
25
86
86
S VIDEO OUT Y level adj.
26
90
90
S VIDEO OUT C level adj.
27
60
60
28 to 2E
Fixed data-1 (Initialized data)
2F
0E
0E
CAP FG/REEL FG duty adj.
30 to 4D
Fixed data-1 (Initialized data)
4E
Fixed data-2
4F
Fixed data-1 (Initialized data)
50
7C
7C
LCD level adj. (VCO adj.)
51
8B
8B
52
89
89
LCD V-COM adj.
53
Fixed data-2
54
Fixed data-1 (Initialized data)
55
Fixed data-2
56
6F
6F
LCD White balance adj.
57
4B
4B
58
75
75
LCD level adj. (Contrast adj.)
59 to 5B
Fixed data-1 (Initialized data)
5C
5D
Fixed data-2
5E to 65
Fixed data-1 (Initialized data)
66
Fixed data-2
67 to 74
Fixed data-1 (Initialized data)
75
Fixed data-2
76 to AC
Fixed data-1 (Initialized data)
AD
Fixed data-2
AE to D2
Fixed data-1 (Initialized data)
D3
D4
D5
Fixed data-2
D6
D7 to DE
Fixed data-1 (Initialized data)
DF
Fixed data-2
E0
08
08
Node unique ID No. input
E1
00
00
E2
46
46
Address
Initial value
Remark
NTSC PAL
E3
01
01
Node unique ID No. input
E4
02
02
E5
00
00
E6
00
00
E7
00
00
E8 to F3
Fixed data-1 (Initialized data)
F4
00
00
Emergency memory
F5
00
00
F6
00
00
F7
00
00
F8
00
00
F9
00
00
FA
00
00
FB
00
00
FC
00
00
FD
00
00
FE
00
00
FF
00
00
DCR-TRV255E/TRV260/TRV265/TRV265E
6-12
5.
1C Page Table
Note 1:
If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 08
Fixed data-1 (Initialized data)
09
FF
FF
Test mode
0A to B2
Fixed data-1 (Initialized data)
B3
00
00
SD error rate check (LP)
B4
00
00
B5
00
00
B6
00
00
B7
00
00
B8
80
80
B9
00
00
BA
00
00
BB
00
00
BC
00
00
BD
00
00
BE
00
00
BF
00
00
C0
00
00
C1
00
00
C2
00
00
C3
80
80
C4
00
00
C5
00
00
C6
00
00
C7
00
00
C8
00
00
C9 to CF
Fixed data-1 (Initialized data)
D0
Fixed data-2
D1 to FF
Fixed data-1 (Initialized data)
DCR-TRV255E/TRV260/TRV265/TRV265E
6-13
1-2-4.
Initialization of E, F, 1F Page Data
Note:
 Check that the data of page: 0, address: 10 is “00”.
1.
Initializing the E, F, 1F Page Data
Note 1:
If “Initialization of Pages E, F, 1F” is executed, all data
on pages E, F, 1F are initialized. (Only an individual page
cannot be initialized)
Note 2:
If the E, F, 1F page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of E, F, 1F page data
2) “27 MHz Origin Oscillation Adjustment” of video
system adjustments
3) Camera system adjustments
Note 3:
NTSC model: DCR-TRV260/TRV265
PAL model: DCR-TRV255E/TRV265E
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
6
03
01
4
6
01
Set the following data, and
press PAUSE button.
2D: NTSC model
2F: PAL model
5
6
02
Check the data changes to
“01”.
6
Perform “Modification of E,
F, 1F Page Data”
2.
Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 1F, set data: 01 to page: 0,
address: 10, and then select pages F. After the modification of
data finished, return the data on page: 0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification E, F, 1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
3.
E Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 0F
Fixed data-1 (Initialized data)
10
Fixed data-2
11 to B0
Fixed data-1 (Initialized data)
B1
Fixed data-2
B2 to FF
Fixed data-1 (Initialized data)
DCR-TRV255E/TRV260/TRV265/TRV265E
6-14
4. F Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
80
80
27 MHz origin osillation adj.
11
Fixed data-1 (Initialized data)
12
4A
4A
Hall adj.
13
56
56
14
11
11
15
20
20
16
02
02
17
E0
E0
18, 19
Fixed data-1 (Initialized data)
1A
00
00
LV standard data input
1B
60
60
1C to 29
Fixed data-1 (Initialized data)
2A
29
1B
Auto white balance
2B
00
00
standard data input
2C
07
07
2D
00
00
2E
17
0E
Auto white balance adj.
2F
00
00
30
0B
0D
31
00
00
32
Fixed data-1 (Initialized data)
33
22
22
Color reproduction adj.
34
Fixed data-1 (Initialized data)
35
27
24
Color reproduction adj.
36 to 39
Fixed data-1 (Initialized data)
3A
00
00
Color reproduction adj.
3B
F1
EF
3C, 3D
Fixed data-1 (Initialized data)
3E
2A
2B
Auto white balance adj.
3F
C0
00
40
59
59
41
00
40
42, 43
Fixed data-1 (Initialized data)
44
28
28
Flange back adj.
45
EC
EC
46
35
35
47
8F
8F
48
13
13
49
B8
B8
4A
00
00
4B
00
00
4C
00
00
4D
00
00
4E
2B
2B
Address
Initial value
Remark
NTSC PAL
4F
19
19
Flange back adj.
50
00
00
51
32
32
52
04
04
53
00
00
54
00
00
55 to 59
Fixed data-1 (Initialized data)
5A
FF
FF
Optical axis adj.
5B to 8D
Fixed data-1 (Initialized data)
8E
8F
Fixed data-2
90
91 to 96
Fixed data-1 (Initialized data)
97
Fixed data-2
98, 99
Fixed data-1 (Initialized data)
9A
Fixed data-2
9B to A3
Fixed data-1 (Initialized data)
A4
Fixed data-2
A5 to C4
Fixed data-1 (Initialized data)
C5
C6
Fixed data-2
C7 to FF
Fixed data-1 (Initialized data)
5.
1F Page Table
Note 1:
If reading/writing data on pages 1F, set data: 01 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 7B
Fixed data-1 (Initialized data)
7C
Fixed data-2
7D to FF
Fixed data-1 (Initialized data)
Page of 56
Display

Click on the first or last page to see other DCR-TRV255E / DCR-TRV260 / DCR-TRV265 / DCR-TRV265E (serv.man3) service manuals if exist.