Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv250-sm4.pdf
Date

Sony DCR-TRV250 (serv.man4) Service Manual ▷ View online

DCR-TRV250
6-59
2-3.
MSW Codes
• The lower parts of the data of addresses F6, FA and FE repre-
sent the MSW codes (mode switch, mechanism position) when
errors occurs.
• The upper parts of the data of addresses F6, FA and FE repre-
sent, when the mechanism position is to be moved, the MSW
codes at the start of movement (when moving the loading mo-
tor).
• The lower parts of the data of addresses F7, FB and FF repre-
sent the MSW codes of the desired movement when the mecha-
nism position is to be moved.
0001=1
0111=7
0011=3
0010=2
0111=7
0101=5
0111=7
0111=7
0000=0
0111=7
0100=4
0111=7
0110=6
Mechanism position
MODE SW C
MODE SW B
MODE SW A
MSB
Unloading
Releasing lock of 
cassette campartment
LS chassis movement range
Pinch roller is pressed
Pinch roller is detached
EJECT
BL
USE
LOAD
BL
REW
BL
BL
REC/PB
BL
TURN
BL
STOP
Loading
Contents
Position at which the cassette compartment lock is released. The mechanism will not move any
further in the unloading direction.
BLANC code. Between two codes. The mechanism will not be stopped by this code while it is
operating.
EJECT completion position. When the cassette is ejected, the mechanism will stop at this
position.
Code during loading/unloading. Code that is used while the LS chassis is moving.
Normal stop position. The pinch roller separates, the tension regulator returns, and the brakes of
both reels turn on.
Position at which is used when the pendulum gear swings from S to T or from T to S.
PB, REC, CUE, REV, PAUSE, FF positions.
The pinch roller is pressed and tension regulator is on.
REW position. REW are carried at this position.
The mechanism will not move any further in the loading direction.
Mechanism Position
EJECT
BL
USE
LOAD
STOP
TURN
REC/PB
REW
MSW Code
1
7
3
2
6
4
0
5
DCR-TRV250
6-60
3. Bit Value Discrimination
Bit values must be discriminated using the display data of the ad-
justment remote commander for the following items.  Us the table
below to discriminate if the bit value is “1” or “0”.
(Example) If the remote commander display is “8E”, bit value from
bit 7 to bit 4 can be discriminated from the column 
A
,
and those from bit 3 to bit 0 from column 
B
.
4. Switch Check (1)
Page 7
Address 0E
Using method:
1) Select page: 7, address: 0E.
2) By discriminating the bit value of display data, the state of the
switches can be discriminated.
5. Switch Check (2)
Using method:
1) Select page: 7, address: 0C.
2) By discriminating the bit value of display data, the state of the
switch can be discriminated.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
C
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
A
B
Page 7
Address 0C
Bit
2
3
Function
A/V OUT jack (FP-577 flexible)
S VIDEO jack (FP-577 flexible)
When bit value = 1
Used
Used
When bit value = 0
Not used
Not used
Bit
0
1
2
3
4
5
6
7
Function
POWER SW (VTR MODE SW)
(SS-3000 block S001)
POWER SW (CAM MODE SW)
(SS-3000 block S001)
BATT INFO SW (FK-3000 block S002)
EJECT SW (SS-3000 block S003)
CC DOWN SW (Mechanism chassis)
PHOTO SW (POTO FREEZE SW)
(SS-3000 block S004)
When bit value = 1
OFF
OFF
OFF
OFF
OFF (UP)
OFF
When bit value = 0
ON (VCR)
ON (CAMERA)
ON
ON
ON (DOWN)
ON
DCR-TRV250
6-61
6. Switch Check (3)
Page 2
Address 60 to 63, 65, 67
Using method:
1) Select page: 2, address: 60 to 63, 65 and 67.
2) By discriminating the display data, the pressed key can be discriminated.
7. LED, Video Light, IR Light Check
Using method:
1) Set the unit to camera mode.
2) Select page: 7, address: 07, and set the bit value of bit5 to “1”.
3) Check that all LED are lit, that the IR light is lit, and that the video light is lit.
4) Select page: 7, address: 07, and set the bit value of bit5 to “0”.
Page 7
Address 07
Bit5
Address
60
(KEY AD0)
(IC5001 
tl
)
61
(KEY AD1)
(IC5001 
y;
)
62
(KEY AD2)
(IC5001 
ya
)
63
(KEY AD3)
(IC5001 
yg
)
65
(KEY AD5)
(IC5001 
yj
)
67
(KEY AD7)
(IC5001 
yl
)
00 to 0C
FOCUS
(CF-3000 block)
(S007)
PAUSE
(FK-3000 block)
(S003)
PHOTO
(PHOTO START)
(SS-3000 block)
(S004)
START/STOP
(SS-3000 block)
(S002)
0D to 24
LIGHT
(FK-3000 block)
(S004)
BACKLIGHT
(CF-3000 block)
(S009)
END
SEARCH
(CF-3000 block)
(S008)
EXPOSURE
(CF-3000 block)
(S005)
25 to 3F
STOP
(FK-3000 block)
(S005)
FADER
(CF-3000 block)
(S014)
MENU
EXECUTE
(CF-3000 block)
(S023)
TITLE
(CF-3000 block)
(S010)
40 to 5D
FF
(FK-3000 block)
(S006)
VOLUME +
(CF-3000 block)
(S019)
MENU
(CF-3000 block)
(S012)
5E to 81
REW
(FK-3000 block)
(S007)
VOLUME –
(CF-3000 block)
(S021)
DISPLAY
(CF-3000 block)
(S015)
PANEL
REVERSE
(PR-3000 block)
(S601)
82 to AA
PLAY
(FK-3000 block)
(S008)
PANEL
CLOSE
(CF-3000 block)
(S001)
AB to D7
REC
(FK-3000 block)
(S009, S010)
D8 to FF
No key input
No key input
No key input
PANEL
OPEN
(CF-3000 block)
(S001)
PANEL
NORMAL
(PR-3000 block)
(S601)
No key input
Data
DCR-TRV250
6-62
8. Record of Use Check
Page 7
Address A7 to A9, C8 to CF
Using method:
1) The record of use data is displayed at page: 7, addresses: A7 to
A9 and C8 to CF.
Note 1:
 This data will be erased (reset) when the cabinet (R) as-
sembly (VC-305 board CN1007 (18P)) is removed.
Note 2:
When the drum was replaced, initialize the drum rota-
tion counted time.
Note 3:
When replacing the video light, initialize the data of ad-
dress: CE and CF.
Note 4:
Video light counted time is indicated in hexadecimal
notation. Convert hexadecimal numbers to decimals be-
fore useing them.
Initializing method of drum rotation counted time:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 7, address: A7, set data: 00, and press the PAUSE
button.
3) Select address: A8 and A9 and set data “00” into them in the
same way as in address: A7.
4) Select page: 0, address: 01, and set data: 00.
Address
A7
A8
A9
C8
C9
CA
CB
CC
CD
CE
CF
Function
Drum rotation
Hour
counted time
Hour
(BCD code)
Hour
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Video light
Hour (H)
counted time (Note 4)
Hour (L)
Remarks
100000th place digit and 10000th place digit of counted time (decimal digit)
1000th place digit and 100th place digit of counted time (decimal digit)
10th place digit and 1st place digit of counted time (decimal digit)
After setting the clock, set the date of power on next
1000th place digit and 100th place digit of counted time (hexadecimal digit)
10th place digit and 1st place digit of counted time (hexadecimal digit)
Page of 67
Display

Click on the first or last page to see other DCR-TRV250 (serv.man4) service manuals if exist.