Sony DCR-TRV250 (serv.man4) Service Manual ▷ View online
DCR-TRV250
6-31
COVER
COVER
1-4.
ELECTRONIC VIEWFINDER SYSTEM AD-
JUSTMENTS
JUSTMENTS
Before perform the viewfinder system adjustments, check that the
data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Note 1:
Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
display module by static electricity when replacing it.
Note 2:
Perform the following data setting before the viewfinder
system adjustments.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
system adjustments.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN1011 of the VC-305 board.
Connect the measuring instruments via I/F unit for LANC control
(J-6082-521-A) and CPC jig connector (J-6082-539-A).
are concentrated in CN1011 of the VC-305 board.
Connect the measuring instruments via I/F unit for LANC control
(J-6082-521-A) and CPC jig connector (J-6082-539-A).
The following table shows the pin No. and signal name of CN1011.
Pin No.
Signal Name
Pin No.
Signal Name
1
FRRV
9
RF MON
2
8 mm PB RF
10
REG GND
3
BPF MONI
11
N.C.
4
CAP FG
12
N.C.
5
RF SWP
13
XLANC POWER ON
6
REG GND
14
EVF VG
7
XLANC JACK IN
15
VCO
8
REG GND
16
LANC SIG
Table 6-1-2
The following table lists the test point of I/F unit of for LANC
control.
control.
Pin No.
Signal Name
Pin No.
Signal Name
BL
15
EVF VCO
14
EVF VG
BL 4.75
9
PB RF (MON)
3
BPF MONI
6, 8, 10
GND
TMS
7
REC RF (RF IN)
TDI
TDO
5
SWP
TCK
4
CAP FG
2
IR VIDEO
Note:
Pin No. are those of CN1011.
Table 6-1-3
CN1011
16
1
Conductor
side
side
Fig. 6-1- 15
DCR-TRV250
6-32
1. VCO Adjustment (VC-305 board)
Set the VCO free-run frequency. If deviated, the EVF screen will
be blurred.
be blurred.
Mode
CAMERA
Subject
Not required
Measurement Point
EVF VCO (Pin qg of CN1011)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
36, 37
Specified Value
f = 15734
± 30 Hz
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
36
Change the data and set the
frequency (f) to the specified
value.
frequency (f) to the specified
value.
3
C
36
Press PAUSE button.
4
C
36
Read the data and this data is
named D
named D
36
.
5
Convert D
36
to decimal
notation, and obtain D
36
’.
(Note 2)
6
Calculate D
37
’ using
following equations.
(decimal calculation)
D
(decimal calculation)
D
37
’ = D
36
’ + 19
7
Convert D
37
’ to a hexadeci-
mal number, and obtain D
37
.
(Note 2, 3)
8
C
37
D
37
Press PAUSE button.
9
0
01
00
Note 2:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”
table”
Note 3:
If D
37
’ > 255, then D
37
= FF
DCR-TRV250
6-33
2-2. Manual Adjustment
Mode
CAMERA
Subject
Not required
Measurement Point
EVF VG (Pin qf of CN1011)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
39
Specified Value
A = 7.50
± 0.10 Vp-p
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
39
Change the data and set the
voltage (A) to the specified
value.
voltage (A) to the specified
value.
3
C
39
Press PAUSE button.
4
0
01
00
2. RGB AMP Adjustment (VC-305 board)
Set the D Range of the RGB decoder for driving the LCD to the
specified value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
specified value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
Note:
Do either of the automatic adjustment or manual adjust-
ment.
ment.
2-1. Automatic Adjustment
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Adjustment Page
C
Adjustment Address
39
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) PANEL OPEN/CLOSE ............................................... CLOSE
1) PANEL OPEN/CLOSE ............................................... CLOSE
(LCD panel turns off)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
01
50
Press PAUSE button. (Note 2)
3
3
02
Check the data changes to
“00”.
“00”.
4
0
01
00
Note 2:
The adjustment data will be automatically input to page:
C, address: 39.
C, address: 39.
A: Between the reversed waveform pedestal
and non-reversed waveform pedestal
Fig. 6-1-16
A
2H
Pedestal
Pedestal
DCR-TRV250
6-34
3. Contrast Adjustment (VC-305 board)
Set the video signal level for driving the LCD to the specified
value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
Note:
Do either of the automatic adjustment or manual adjust-
ment.
ment.
3-1. Automatic Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Adjustment Page
C
Adjustment Address
3E
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) PANEL OPEN/CLOSE ............................................... CLOSE
1) PANEL OPEN/CLOSE ............................................... CLOSE
(LCD panel turns off)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
01
51
Press PAUSE button. (Note 2)
3
3
02
Check the data changes to
“00”.
“00”.
4
0
01
00
Note 2:
The adjustment data will be automatically input to page:
C, address: 3E.
3-2. Manual Adjustment
Mode
CAMERA
Subject
Not required
Measurement Point
EVF VG (Pin qf of CN1011)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
3E
Specified Value
A = 2.55
± 0.1 Vp-p
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
3E
Change the data and set the
voltage (A) to the specified
value.
(The data should be “00” to
“7F”)
voltage (A) to the specified
value.
(The data should be “00” to
“7F”)
3
C
3E
Press PAUSE button.
4
0
01
00
A
2H
100 IRE
Pedestal
A: Between the pedestal (0 IRE) and 100 IRE
Fig. 6-1-17