Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv250-sm4.pdf
Date

Sony DCR-TRV250 (serv.man4) Service Manual ▷ View online

DCR-TRV250
6-31
COVER
COVER
1-4.
ELECTRONIC VIEWFINDER SYSTEM AD-
JUSTMENTS
Before perform the viewfinder system adjustments, check that the
data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Note 1:
Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
Note 2:
Perform the following data setting before the viewfinder
system adjustments.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN1011 of the VC-305 board.
Connect the measuring instruments via I/F unit for LANC control
(J-6082-521-A) and CPC jig connector (J-6082-539-A).
The following table shows the pin No. and signal name of CN1011.
Pin No.
Signal Name
Pin No.
Signal Name
1
FRRV
9
RF MON
2
8 mm PB RF
10
REG GND
3
BPF MONI
11
N.C.
4
CAP FG
12
N.C.
5
RF SWP
13
XLANC POWER ON
6
REG GND
14
EVF VG
7
XLANC JACK IN
15
VCO
8
REG GND
16
LANC SIG
Table 6-1-2
The following table lists the test point of I/F unit of for LANC
control.
Pin No.
Signal Name
Pin No.
Signal Name
BL
15
EVF VCO
14
EVF VG
BL 4.75
9
PB RF (MON)
3
BPF MONI
6, 8, 10
GND
TMS
7
REC RF (RF IN)
TDI
TDO
5
SWP
TCK
4
CAP FG
2
IR VIDEO
Note:
 Pin No. are those of CN1011.
Table 6-1-3
CN1011
16
1
Conductor 
side
Fig. 6-1- 15
DCR-TRV250
6-32
1. VCO Adjustment (VC-305 board)
Set the VCO free-run frequency. If deviated, the EVF screen will
be blurred.
Mode
CAMERA
Subject
Not required
Measurement Point
EVF VCO (Pin qg of CN1011)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
36, 37
Specified Value
f = 15734 
± 30 Hz
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
36
Change the data and set the
frequency (f) to the specified
value.
3
C
36
Press PAUSE button.
4
C
36
Read the data and this data is
named D
36
.
5
Convert D
36
 to decimal
notation, and obtain D
36
’.
(Note 2)
6
Calculate D
37
’ using
following equations.
(decimal calculation)
D
37
’ = D
36
’ + 19
7
Convert D
37
’ to a hexadeci-
mal number, and obtain D
37
.
(Note 2, 3)
8
C
37
D
37
Press PAUSE button.
9
0
01
00
Note 2:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”
Note 3:
If D
37
’ > 255, then D
37
 = FF
DCR-TRV250
6-33
2-2. Manual Adjustment
Mode
CAMERA
Subject
Not required
Measurement Point
EVF VG (Pin qf of CN1011)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
39
Specified Value
A = 7.50 
± 0.10 Vp-p
Note:
 Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
39
Change the data and set the
voltage (A) to the specified
value.
3
C
39
Press PAUSE button.
4
0
01
00
2. RGB AMP Adjustment (VC-305 board)
Set the D Range of the RGB decoder for driving the LCD to the
specified value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
Note:
Do either of the automatic adjustment or manual adjust-
ment.
2-1. Automatic Adjustment 
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Adjustment Page
C
Adjustment Address
39
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) PANEL OPEN/CLOSE ............................................... CLOSE
(LCD panel turns off)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
01
50
Press PAUSE button. (Note 2)
3
3
02
Check the data changes to
“00”.
4
0
01
00
Note 2:
The adjustment data will be automatically input to page:
C, address: 39.
A: Between the reversed waveform pedestal
and non-reversed waveform pedestal
Fig. 6-1-16
A
2H 
Pedestal
Pedestal
DCR-TRV250
6-34
3. Contrast Adjustment (VC-305 board)
Set the video signal level  for driving the LCD to the specified
value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
Note:
Do either of the automatic adjustment or manual adjust-
ment.
3-1. Automatic Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Adjustment Page
C
Adjustment Address
3E
Note 1:
 Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) PANEL OPEN/CLOSE ............................................... CLOSE
(LCD panel turns off)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
01
51
Press PAUSE button. (Note 2)
3
3
02
Check the data changes to
“00”.
4
0
01
00
Note 2:
 The adjustment data will be automatically input to page:
C, address: 3E.
3-2. Manual Adjustment
Mode
CAMERA
Subject
Not required
Measurement Point
EVF VG (Pin qf of CN1011)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
3E
Specified Value
A = 2.55 
± 0.1 Vp-p
Note:
 Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
3E
Change the data and set the
voltage (A) to the specified
value.
(The data should be “00” to
“7F”)
3
C
3E
Press PAUSE button.
4
0
01
00
A
2H 
100 IRE
Pedestal
A: Between the pedestal (0 IRE) and 100 IRE
Fig. 6-1-17
Page of 67
Display