DOWNLOAD Sony DCR-TRV24E / DCR-TRV25E / DCR-TRV27E (serv.man2) Service Manual ↓ Size: 10.8 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV24E DCR-TRV25E DCR-TRV27E (serv.man2)
Pages
127
Size
10.8 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv24e-dcr-trv25e-dcr-trv27e-sm2.pdf
Date

Sony DCR-TRV24E / DCR-TRV25E / DCR-TRV27E (serv.man2) Service Manual ▷ View online

5-16
DCR-TRV24E/TRV25E/TRV27E
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Table. 5-1-9.
Address
Remark
00 to 07
08
09
0A
0B
0C to 0D
0E
0F to 1A
1B
1C
1D
1E to 1F
20
21
22
23
24
25
26
27
28 to 37
38
39
3A to 3B
3C
3D
3E
3F
40 to 41
42
43 to 45
46
47
48 to 53
54
55
56 to 65
66
67
68
69
6A to 6E
6F
70
71 to 85
86
87 to DF
E0
E1
E2
E3
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
E4
E5
E6
E7
E8
E9
EA
EB to FF
Address
Remark
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
5-17
DCR-TRV24E/TRV25E/TRV27E
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
00 to FF
10
11 to 12
13
14
15
16
17
18
19
1A
1B
1C to 2F
30
31
32
33
34
35
36
37
38
39
3A to 3F
40
41
42 to 44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
40
28
70
28
40
80
D8
A0
80
7A
4D
3E
64
59
96
7A
2C
26
01
E8
3F
10
39
C2
1E
2E
00
00
00
00
6E
19
00
19
00
00
00
80
80
54MHz origin osc. adj.
Fixed data-1
HALL adj.
MAX GAIN adj.
AWB & LV standard data input
Fixed data-1
AWB & LV standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Flange back adj.
Fixed data-1
MR adj.
Address
Remark
Initial value
Address
Remark
Initial value
5C
5D
5E
5F
60
61
62
63
64
65
6D to 71
72
73 to 75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C to 97
98
99
9A
9B
9C
9D to A7
A8
A9 to CF
D0
D1 to D6
D7
D8 to D9
DA
DB
DC to DD
DE
DF
E0 to E6
E7
80
80
40
C0
40
C0
40
C0
40
C0
40
00
34
00
30
00
2A
00
28
00
40
3A
31
31
35
1E
80
80
80
80
80
80
MR adj.
Fixed data-1
Fixed data-2
Fixed data-1
Mechanical shutter adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2(Modified data. Copy the
data built in the same model.)
Fixed data-1
Fixed data-2
5-18
DCR-TRV24E/TRV25E/TRV27E
Table. 5-1-10.
Address
Remark
Initial value
E8 to F4
F5
F6
F7
F8
F9
FA to FD
FE
FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
F Page
5. 1E Page Table
Note1:
When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Table. 5-1-11.
Address
Remark
Initial value
00 to 0F
10
11 to 1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35 to 37
38
39 to 51
52
53
54
55
56
57 to 71
72
73
74 to 80
81
82
83 to 84
85
86
87 to BF
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Black defective CCD adj.
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
5-19
DCR-TRV24E/TRV25E/TRV27E
6. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
00 to 38
39
3A to 44
45
46
47 to 4F
50
51
52
53
54
55 to 5A
5B
5C
5D
5E to 6F
70
71
72 to A1
A2
A3 to AB
AC
AD
AE to B0
B1
B2
B3
B4
B5 to B8
B9
BA
BB to C9
CA
CB
CC
CD
CE
CF to D1
D2
D3
D4 to FF
Address
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-12.
Page of 127
Display

Click on the first or last page to see other DCR-TRV24E / DCR-TRV25E / DCR-TRV27E (serv.man2) service manuals if exist.