DOWNLOAD Sony DCR-TRV24E / DCR-TRV25E / DCR-TRV27E (serv.man2) Service Manual ↓ Size: 10.8 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV24E DCR-TRV25E DCR-TRV27E (serv.man2)
Pages
127
Size
10.8 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv24e-dcr-trv25e-dcr-trv27e-sm2.pdf
Date

Sony DCR-TRV24E / DCR-TRV25E / DCR-TRV27E (serv.man2) Service Manual ▷ View online

5-28
DCR-TRV24E/TRV25E/TRV27E
11. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
34, 35
Specified Value
R ratio: 2B3C to 2C3C
B ratio: 57C8 to 58C8
Note1:
This adjustments should be carried out upon completion of “Auto
White Balance & LV Standard Data Input”.
Note2:
After the power is turned on, this adjustment can be done only
once.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu display) ................................... OFF
5)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
0
01
01
Set the data.
3
F
44
Write down the data.
4
F
44
2B
Set the data, and press PAUSE
button.
5
F
45
Write down the data.
6
F
45
BC
Set the data, and press PAUSE
button.
7
F
46
Write down the data.
8
F
46
58
Set the data, and press PAUSE
button.
9
F
47
Write down the data.
10
F
47
48
Set the data, and press PAUSE
button.
11
6
01
83
Set the data, and press PAUSE
button.
12
6
01
81
Set the data, and press PAUSE
button.
13
6
02
Check that the data changes to
“01”. (Note5)
14
6
01
3F
Set the data, and press PAUSE
button.
15
0
03
04
Set the data.
16
1
Check that the display data
(Note4) satisfies the R ratio
specified value.
17
0
03
05
Set the data.
18
1
Check that the display data
(Note4) satisfies the B ratio
specified value.
Note5:
The adjustment data will be automatically input to page: F, address:
34, 35.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
F
44
Set the data that is written down
at step 3, and press PAUSE button.
2
F
45
Set the data that is written down
at step 5, and press PAUSE button.
3
F
46
Set the data that is written down
at step 7, and press PAUSE button.
4
F
47
Set the data that is written down
at step 9, and press PAUSE button.
5
6
01
00
Set the data, and press PAUSE
button.
6
0
03
00
Set the data.
7
0
01
00
Set the data.
5-29
DCR-TRV24E/TRV25E/TRV27E
12. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-13. A to B
Note1:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu display) ................................... OFF
5)
STEADY SHOT (Menu display) ..................................... OFF
Checking method:
Order Page Address Data
Procedure
Indoor white balance check
1
Check that the lens is not
covered with either filter.
2
6
01
0F
Set the data, and press PAUSE
button.
3
Check that the center of the
white luminance point is within
the circle shown Fig. 5-1-13. A.
4
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
5
Place the C14 filter on the lens.
6
6
01
3F
Set the data, and press PAUSE
button.
7
Check that the center of the
white luminance point is within
the circle shown Fig. 5-1-13. B.
8
Remove the C14 filter.
LV data check
9
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
10
6
01
00
Set the data, and press PAUSE
button.
11
0
03
06
Set the data.
12
1
Check that the display data
(Note2) satisfies the specified
value.
Specified value: 8000 to 8BC0
Note2:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
Fig. 5-1-13(A).
Fig. 5-1-13(B).
R-Y
2mm
B-Y
2mm
R-Y
B-Y
1mm
1mm
3mm
3mm
5-30
DCR-TRV24E/TRV25E/TRV27E
13. Mechanical Shutter Adjustment
Adjustment Page
F
Adjustment Address
76 to 8B
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 76 to 8B.
Note:
Press the PAUSE button of the adjustment remote commander each
time to set the data.
3)
Select page: 0, address: 01, and set data: 00.
Address
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
Data
4B
00
3D
00
35
00
2F
00
27
00
66
7D
7D
6F
61
1F
80
80
80
80
80
80
14. Black Defective CCD Adjustment
Detect the black defective positions of the CCD imager.
Subject
Clear chart (All white)
(Approx. 40cm from the front of the lens)
Adjustment Page
1E (Note1)
Adjustment Address
20 to 2F
Note1:
When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
This adjustment should be carried out upon completion of “Flange
Back Adjustment”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
2C
01
Set the data.
4
6
9C
01
Set the data.
5
6
90
50
Set the data.
6
6
91
01
Set the data.
7
6
92
00
Set the data.
8
6
93
01
Set the data.
9
6
01
79
Set the data, and press PAUSE
button.
10
Adjust the direction of the
camera so that the whole of the
screen is white.
11
6
01
8D
Set the data, and press PAUSE
button.
12
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: 1E,
address: 20 to 2F
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
2C
00
Set the data.
4
6
9C
00
Set the data.
5
6
90
00
Set the data.
6
6
91
00
Set the data.
7
6
93
00
Set the data.
8
0
01
00
Set the data.
5-31
DCR-TRV24E/TRV25E/TRV27E
15. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: CG-L43A0
Type B: CG-L43A1
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2B00 to 4B00
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (Menu display) ...................................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(JK-217 board SE5302)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value.
Yaw sensor check
(JK-217 board SE5301)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
Move the camcorder, and check
that the steady shot operations
have been performed normally
Page of 127
Display

Click on the first or last page to see other DCR-TRV24E / DCR-TRV25E / DCR-TRV27E (serv.man2) service manuals if exist.