5-16
DCR-TRV240/TRV340
Table. 5-1-10.
Table. 5-1-12.
3A
3B
3C to 45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57 to 5B
5C
5D
5E
5F to 8D
8E
8F to 93
94
95 to 99
9A
9B to C7
C8
C9 to D6
D7
D8 to ED
EE
EF to F6
F7
F8 to FF
00
F1
2A
18
37
0D
13
08
00
00
00
00
6E
19
00
19
04
00
00
00
Color reproduction adj.
Fixed data-1
Flange back adj.
Fixed data-1
Fixed data-2
Optical axis adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
4. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”.)
00 to 05
06
07
08 to 35
36
37 to 9B
9C
9D
9E
9F
A0
A1
A2 to AA
AB
AC to BE
BF
C0
C1
C2
C3
C4
C5 to E9
EA
EB
EC to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in the same
model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Table. 5-1-11.
5. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”.)
00 to 51
52
53 to 5A
5B
5C to 64
65
66
67 to D8
D9
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Address
Remark
F page
5-17
DCR-TRV240/TRV340
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
17, 18, 19
Specified Value 1
89 to 8D
Specified Value 2
15 to 19
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
8B
Set the data.
3
6
95
17
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note3)
6
6
01
00
Set the data, and press PAUSE
button.
Note3:
The adjustment data will be automatically input to page: F, address:
17, 18, 19.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
0
03
00
Set the data.
4
6
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
RadarW
RadarW
RadarW
5-18
DCR-TRV240/TRV340
2. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for the
minipattern box (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
Dark Siemens star chart.
Note2:
This adjustment should be carried out upon completion of “HALL
adjustment”.
Note3:
Make the lens horizontal and perform this adjustment.
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, set data:
00 to this address, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
SLOW SHUTTER/SUPER NIGHT SHOT ..................... OFF
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note:
The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage:
The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button.
4
6
01
27
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note6)
Note6:
The adjustment data will be automatically input to page: F, address:
46 to 56.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”.
RadarW
RadarW
RadarW
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
Fig. 5-1-7.
5-19
DCR-TRV240/TRV340
3. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
3-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass) (Luminance: 350 ± 50 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
This adjustment should be carried out upon completion of “HALL
adjustment”.
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, set data:
00 to this address, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
SLOW SHUTTER/SUPER NIGHT SHOT ..................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button.
4
6
01
15
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note5)
Note5:
The adjustment data will be automatically input to page: F, address:
46 to 56.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
Turn off the power and turn on
again.
2
Perform “Flange Back Adjustment
(2)”
3-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
46 to 56
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, set data:
00 to this address, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
SLOW SHUTTER/SUPER NIGHT SHOT ..................... OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button.
4
Place a ND filter on the lens so
that the optimum image is obtain.
5
6
01
29
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
46 to 56.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”.