Sony DCR-TRV238E / DCR-TRV239E (serv.man2) Service Manual ▷ View online

5-47
DCR-TRV238E/TRV239E
3. S VIDEO OUT Chroma Level Adjustment
(VC-276 board)
Mode
VTR stop
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
jack (75
 terminated)
External trigger: Y signal terminal of
S VIDEO jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified Value
Cr level: A = 700 ± 14mV
Cb level: B = 700 ± 14mV
Burst level: C =300 ± 6mV
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
FE
10
Set the data, and press PAUSE
button.
3
3
0C
02
Set the data, and press PAUSE
button.
4
C
26
Change the data and set the Cr signal
level (A) to the specified value.
5
C
26
Press PAUSE button.
6
C
27
Change the data and set the Cb signal
level (B) to the specified value.
7
C
27
Press PAUSE button.
8
Check that the burst signal level
(C) is satisfied the specified value.
9
3
0C
00
Set the data, and press PAUSE
button.
10
D
FE
00
Set the data, and press PAUSE
button.
11
0
01
00
Set the data.
4. VIDEO OUT Y, Chroma Level Check (VC-276 board)
Mode
VTR stop
Signal
No signal
Measurement Point
Video signal terminal of AUDIO/
VIDEO jack (75
 terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level: A = 307 ± 18mV
Burst level: B = 300 ± 18mV
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
FE
10
Set the data, and press PAUSE
button.
3
3
0C
02
Set the data, and press PAUSE
button.
4
Check that the sync signal level
(A) satisfies the specified value.
5
Check that the burst signal level
(B) satisfies the specified value.
6
3
0C
00
Set the data, and press PAUSE
button.
7
D
FE
00
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
Fig. 5-3-8.
H
C
A
0.23 
µ
sec 
B
0.23 
µ
sec 
Fig. 5-3-9.
H
B
A
Ver 1.2  2002. 09
5-48
DCR-TRV238E/TRV239E
5. Hi8/Standard8 Y/C Output Level Setting
(VC-276 board)
Set the Y/C signal output level during the Hi8/Standard8 playback
mode.
Mode
VTR stop
Signal
No signal
Adjustment Page
C
Adjustment Address
44, 45
Note1:
Perform this adjustment when IC2201 is replaced.
Note2:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
10
02
Set the data, and press PAUSE
button.
3
3
9E
01
Set the data.
4
3
A4
Check that the data.
When the data is “53”, proceed
to step 5.
When the data is “03”, proceed
to step 8.
5
C
44
65
Set the data, and press PAUSE
button.
6
C
45
72
Set the data, and press PAUSE
button.
7
Proceed to step 10.
8
C
44
A0
Set the data, and press PAUSE
button.
9
C
45
B8
Set the data, and press PAUSE
button.
10
3
9E
00
Set the data.
11
D
10
00
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
6. Hi8/standard 8mm AFC fo Adjustment
(VC-276 board)
Adjust the pull-in range of the clock generator (IC2201) for A/D
conversion during Hi8/standard 8mm playback.
Mode
VTR stop
Signal
No signal
Measurement Point
Display data of page: 3, address: 9D
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
43
Specified Value
7C to 84
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
10
02
Set the data, and press PAUSE
button.
3
3
0D
04
Set the data, and press PAUSE
button.
4
3
93
04
Set the data.
5
3
9E
01
Set the data.
6
C
43
50
Set the data, and press PAUSE
button.
7
3
01
60
Set the data, and press PAUSE
button.
8
3
02
Check that the data changes from
“60” to “00”.
9
3
03
Check that the data is “00”.
10
3
01
00
Set the data, and press PAUSE
button.
11
3
9D
Check that the data satisfies the
specifies value.
When the data doesn’t satisfy the
specified value, return to step 6.
12
3
0D
00
Set the data, and press PAUSE
button.
13
3
93
00
Set the data.
14
3
9E
00
Set the data.
15
D
10
00
Set the data, and press PAUSE
button.
16
0
01
00
Set the data.
5-49
DCR-TRV238E/TRV239E
3-5.
AUDIO SYSTEM ADJUSTMENTS
Note:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to the
video system measuring instruments as shown in Fig. 5-3-10.
[Adjustment Procedure]
1)
Hi8/Standard8 AFM BPF f
0
 adjustment
2)
Hi8/Standard8 AFM 1.5MHz deviation adjustment
3)
Hi8/Standard8 AFM 1.7MHz deviation adjustment
4)
Digital8 playback level check
5)
Overall level characteristics check
6)
Overall distortion check
7)
Overall noise level check
8)
Overall separation check
1. Hi8/Standard8 AFM BPF f
0
 Adjustment
(VC-276 board)
Sets the BPF passing frequency of IC5701 so that the AFM signal
can separate from the playback RF signal properly. If deviated. the
mono/stereo mode will be differentiated incorrectly, and noises and
distortions will increase during high volume playback.
Mode
Playback
Signal
Hi8/Standard8 alignment tape:
  For BPF adjustment
  (WR5-11CS)
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Distortion meter
Adjustment Page
C
Adjustment Address
4E
Specified Value
The Main and Sub channel distortion
rate should be almost the same (within
± 1%) and minimum.
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Set the Hi-Fi SOUND switch (menu display) to “2”.
3)
Select page: C, address: 4E, change the data and minimize the
distortion rate.
4)
Press the PAUSE button.
5)
Set the Hi-Fi SOUND switch (menu display) to “1”.
6)
Select page: C, address: 4E, change the data and minimize the
distortion rate.
7)
Press the PAUSE button.
8)
Repeat steps 2) to 7) and set the data of address: 4E so that the
distortions rates when the Hi-Fi SOUND switch is set to “2”
and set to “1” respectively are almost the same and minimum.
9)
Press the PAUSE button.
10) Select page: 0, address: 01, and set data: 00.
11) Set the Hi-Fi SOUND switch to “STEREO”.
Fig. 5-3-10.
Recording (Camera mode)
Audio oscillator
Attenuator
600 
Left
Right
Main unit
MIC
600 
: 270 
 (1-249-410-11) + 330 
 (1-249-411-11)
Main unit
AUDIO/
VIDEO
Left (White)
Right 
47k 
47k 
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k 
 (1-249-437-11)
Playback
(Red)
5-50
DCR-TRV238E/TRV239E
2. Hi8/Standard8 AFM 1.5 MHz Deviation Adjustment
(VC-276 board)
Adjust to the optimum 1.5MHz audio FM signal deviation.
If the adjustment is not correct, its playback level will differ from
that of other units.
Mode
Playback
Signal
Hi8/Standard8 alignment tape:
  For checking AFM stereo operation
  Monoscope section (WR5-9CS)
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Audio level meter
Adjustment Page
C
Adjustment Address
4C
Specified Value
–7.5 ± 2.0dBs
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Set the Hi-Fi SOUND switch (menu display) to “1”.
3)
Select page: C, address: 4C, change the data and set the 400Hz
signal level to the specified value.
4)
Press the PAUSE button.
5)
Set the Hi-Fi SOUND switch (menu display) to “STEREO”.
6)
Select page: 0, address: 01, and set data: 00.
3. Hi8/Standard8 AFM 1.7 MHz Deviation Adjustment
(VC-276 board)
Adjust to the optimum 1.7MHz audio FM signal deviation.
If improper, this causes deteriorated separation (with stereo signal).
Mode
Playback
Signal
Hi8/Standard8 alignment tape:
  For checking AFM stereo operation
  Monoscope section (WR5-9CS)
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
4D
Specified Value
–7.5 ± 2.0dBs
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Set the Hi-Fi SOUND switch (menu display) to “2”.
3)
Select page: C, address: 4D, change the data and set the 1kHz
signal level to the specified value.
4)
Press the PAUSE button.
5)
Set the Hi-Fi SOUND switch (menu display) to “STEREO”.
6)
Select page: 0, address: 01, and set data: 00.
4. Digital8 Playback Level Check
Mode
Playback
Signal
Digital8 alignment tape:
  For audio operation check
  (WR5-3CD)
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Audio level meter and frequency
counter
Specified Value
32 kHz mode: 1 kHz, +3.0 ± 2.0dBs
48 kHz mode: 1 kHz, +3.0 ± 2.0dBs
44.1 kHz mode:
  The 7.35kHz signal level during
  EMP OFF is +2.0 ± 2.0dBs.
  The 7.35kHz signal level during
  EMP ON is –6 ± 2 dB from the
  signal level during EMP OFF.
Checking Method:
1)
Check that the playback signal level is the specified value.
5. Overall Level Characteristics Check
Mode
Recording and playback
Signal
400Hz, –66dBs signal: MIC jack left
and right
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Audio level meter
Specified Value
–7.5 ± 3.0dBs
Checking Method:
1)
Input the 400Hz, –66dBs signal in the MIC jack left and right.
2)
Record the signal.
3)
Playback the recorded section.
4)
Check that the 400Hz signal level is the specified value.
6. Overall Distortion Check
Mode
Recording and playback
Signal
400Hz, –66dBs signal: MIC jack left
and right
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Audio distortion meter
Specified Value
Below 0.4%
(200Hz to 6kHz BPF ON)
Checking Method:
1)
Input the 400Hz, –66dBs signal in the MIC jack left and right.
2)
Record the signal.
3)
Playback the recorded section.
4)
Check that the distortion is the specified value.
Page of 127