Sony DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E (serv.man2) Service Manual ▷ View online

5-15
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
1-2-4.
INITIALIZATION OF E, F, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 1F Page Data
Note1: If “Initializing the E, F, 1F Page Data” is performed, all
data of the E page, F page and 1F page will be initialized.
(It is impossible to initialize a single page.)
Note2:
If the E, F, 1F page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 1F page data
2) 36MHz origin osc. adjustment
3) Camera system adjustments
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Note4:
NTSC model: DCR-TRV16/TRV18
PAL model: DCR-TRV16E/TRV18E/TRV116E/TRV118E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
1F
Adjusting Address
00 to D9
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
FF
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
Perform “Modification of E, F,
1F Page Data”.
2. Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1F page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1F page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
4
Perform “36MHz Origin Osc.
Adjustment” of the camera
system adjustment.
5-16
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Table. 5-1-8.
Address
00 to 10
11
12 to 14
15
16
17
18 to 1B
1C
1D
1E to 36
37
38 to 3C
3D
3E to 6E
6F
70 to 94
95
96 to 97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2 to AD
AE
AF to C1
C2
C3 to E8
E9
EA
EB
EC
ED
EE
EF to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10 to 11
12
13 to 16
17
18
19
1A to 1C
1D
1E
1F
20 to 29
2A
2B
2C
2D
2E
2F
30 to 32
33
34
35
36 to 39
3A
3B
3C to 45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57 to 5B
5C
5D
5E
5F to 65
80
81
5D
17
9A
80
7A
4D
3E
64
59
96
7A
22
27
00
F1
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
00
80
81
5D
17
9A
80
7A
90
3E
43
59
80
40
22
24
00
EF
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
00
Fixed data-1
36MHz origin osc. adj.
Fixed data-1
HALL adj.
Fixed data-1
MAX GAIN adj.
AWB & LV standard data input
Fixed data-1
AWB & LV standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Flange back adj.
Fixed data-1
Fixed data-2
Optical axis adj.
Fixed data-1
5-17
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
80
80
80
80
80
80
40
00
34
00
30
00
2A
00
28
00
70
80
80
80
80
1E
80
80
80
80
80
80
40
00
34
00
30
00
2A
00
28
00
70
80
80
80
80
1E
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C to 92
93
94
95 to 9E
9F
A0 to C3
C4
C5 to C9
CA
CB
CC to D9
DA
DB to DD
DE
DF to E7
E8
E9
EA to EB
EC
ED to F4
F5
F6
F7
F8 to FF
Mechanical shutter adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-9.
5. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
F page
00
01
02 to 05
06
07
08
09
0A to 51
52
53 to 56
57
58 to 59
5A
5B
5C
5D to 64
65
66 to 6B
6C
6D
6E
6F
70 to 73
74
75 to 77
78
79
7A to 7F
80
81 to 97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4 to B0
B1
B2
B3
B4 to B9
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Initial value
NTSC PAL
Address
Remark
5-18
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
Address
Remark
BA
BB to CB
CC
CD
CE
CF
D0
D1 to D9
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
1F page
Table. 5-1-10.
Page of 127
Display

Click on the first or last page to see other DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E (serv.man2) service manuals if exist.