Sony DCR-TRV16 / DCR-TRV16E / DCR-TRV18 / DCR-TRV18E (serv.man2) Service Manual ▷ View online
5-47
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
5. PLL f
0
& LPF f
0
Fine Adjustment (VC-280 Board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Data of page: 3, address: 03 is “00”.
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
30
Set the data, and press PAUSE
button.
button.
3
3
02
Check that the data changes to
“00” with in 5 sec. (Note2)
“00” with in 5 sec. (Note2)
4
3
03
Check that the data is “00”.
(Note3)
(Note3)
5
0
01
00
Set the data.
Note2:
If it isn’t satisfied, there are errors.
Note3:
If the data of page: 3, address: 03 is other than “00”, there are
errors. For the error contents, see the following table. (For the bit
values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”.)
errors. For the error contents, see the following table. (For the bit
values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”.)
Bit value of page: 3,
address: 03
address: 03
bit 2 = 1 or bit 3 = 1
bit 4 = 1 or bit 5 = 1
bit 6 = 1
Error contents
PLL f
0
fine adjustment is defective
PLL f
0
adjustment is defective
LPF f
0
is defective
5-48
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
3-4.
VIDEO SYSTEM ADJUSTMENTS
Note1:
Before perform the video system adjustments, check that the
specified value of “36 MHz Origin Oscillation Adjustment” of
“CAMERA SYSTEM ADJUSTMENT” is satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
specified value of “36 MHz Origin Oscillation Adjustment” of
“CAMERA SYSTEM ADJUSTMENT” is satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Note2:
NTSC model: DCR-TRV16/TRV18
PAL model: DCR-TRV16E/TRV18E/TRV116E/TRV118E
PAL model: DCR-TRV16E/TRV18E/TRV116E/TRV118E
1. Chroma BPF fo Adjustment (VA-117 Board)
Set the center frequency of IC4101 chroma band-pass filter.
Mode
Camera
Subject
Arbitrary
Measurement Point
CH1: Chroma signal terminal of S
VIDEO jack (75
VIDEO jack (75
Ω
terminated)
CH2: Y signal terminal of S VIDEO jack
(75
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
28
Specified Value
A = 100mVp-p or less
B = 200mVp-p or more
B = 200mVp-p or more
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Check that the burst signal (B) is
output to the chroma signal
terminal of S VIDEO jack.
output to the chroma signal
terminal of S VIDEO jack.
3
3
0C
04
Set the data, and press PAUSE
button.
button.
4
C
28
Change the data for minimum
amplitude of the burst signal
level (A).
(The data should be “00” to “0F”.)
amplitude of the burst signal
level (A).
(The data should be “00” to “0F”.)
5
C
28
Press PAUSE button.
6
3
0C
00
Set the data, and press PAUSE
button.
button.
7
Check that the burst signal level
(B) satisfies the specified value.
(B) satisfies the specified value.
8
0
01
00
Set the data.
2. S VIDEO OUT Y Level Adjustment (VC-280 Board)
Mode
Camera
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO jack
(75
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified Value
A = 1000 ± 14mV
Note:
The data of page: 0, address: 10 must be “00”.
Switch setting:
DEMO MODE (Menu setting) ................................................ OFF
DEMO MODE (Menu setting) ................................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
02
Set the data, and press PAUSE
button.
button.
3
C
25
Change the data and set the Y
signal level (A) to the specified
value.
signal level (A) to the specified
value.
4
C
25
Press PAUSE button.
5
3
0C
00
Set the data, and press PAUSE
button.
button.
6
0
01
00
Set the data.
CH1
CH2
A
H
CH1
H
B
When the data of page: 3, address: 0C, is 04:
When the data of page: 3, address: 0C, is 00:
Fig. 5-3-5.
H
Center of luminance line
A
Fig. 5-3-6.
5-49
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
3. S VIDEO OUT Chroma Level Adjustment
(VC-280 Board)
Mode
Camera
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
jack (75
jack (75
Ω
terminated)
External trigger: Y signal terminal of
S VIDEO jack
S VIDEO jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified Value
Cr level: A = 714 ± 14mV (NTSC)
A = 700 ± 14mV (PAL)
Cb level:B = 714 ± 14mV (NTSC)
B = 700 ± 14mV (PAL)
Burst level: C = 286 ± 6mV (NTSC)
C = 300 ± 6mV (PAL)
Note:
The data of page: 0, address: 10 must be “00”.
Switch setting:
DEMO MODE (Menu setting) ................................................ OFF
DEMO MODE (Menu setting) ................................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
02
Set the data, and press PAUSE
button.
button.
3
C
26
Change the data and set the Cr
signal level (A) to the specified
value.
signal level (A) to the specified
value.
4
C
26
Press PAUSE button.
5
C
27
Change the data and set the Cb
signal level (B) to the specified
value.
signal level (B) to the specified
value.
6
C
27
Press PAUSE button.
7
Check that the burst signal level
(C) is satisfied the specified value.
(C) is satisfied the specified value.
8
3
0C
00
Set the data, and press PAUSE
button.
button.
9
0
01
00
Set the data.
4. VIDEO OUT Y, Chroma Level Check (VC-280 Board)
Mode
Camera
Subject
Arbitrary
Measurement Point
Video terminal of AUDIO VIDEO
jack (75
jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level: A = 286 ± 18mV (NTSC)
A = 300 ± 18mV (PAL)
Burst level: B = 286 ± 18(mV (NTSC)
B = 300 ± 18mV (PAL)
Note:
The data of page: 0, address: 10 must be “00”.
Switch setting:
DEMO MODE (Menu setting) ................................................ OFF
DEMO MODE (Menu setting) ................................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
3
0C
02
Set the data, and press PAUSE
button.
button.
2
Check that the sync signal level
(A) satisfies the specified value.
(A) satisfies the specified value.
3
Check that the burst signal level
(B) satisfies the specified value.
(B) satisfies the specified value.
4
3
0C
00
Set the data, and press PAUSE
button.
button.
H
C
A
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
B
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
H
B
A
Fig. 5-3-7.
Fig. 5-3-8.
5-50
DCR-TRV16/TRV16E/TRV18/TRV18E/TRV116E/TRV118E
3-5.
AUDIO SYSTEM ADJUSTMENTS
[Connection of Audio System Measuring Devices]
Connect the audio system measuring devices as shown in Fig. 5-3-9.
Fig. 5-3-9.
Recording (Camera mode)
Audio oscillator
Attenuator
600
Ω
Left
Right
Main unit
MIC
600
Ω
: 270
Ω
(1-249-410-11) + 330
Ω
(1-249-411-11)
Main unit
AUDIO/
VIDEO
OUT
Left (White)
Right
47k
Ω
47k
Ω
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k
Ω
(1-249-437-11)
Playback
(Red)