Sony DCR-TRV140 Service Manual ▷ View online

5-26
DCR-TRV140
1-5.
LCD SYSTEM ADJUSTMENTS
Note 1:
The back light (fluorescent tube) is driven by a high volt-
age AC power supply. Therefore, do not touch the back
light holder to avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent dam-
ages caused by static electricity.
Note 3:
Set the LCD BRIGHT (Menu setting) to the center.
Set the LCD B.L. (Menu setting) to the BRT NORMAL.
Set the LCD COLOR (Menu setting) to the center.
 [Adjusting connector]
Most of the measuring points for adjusting the LCD display are
concentrated in the following connector.
CN5502 of the PD-156 board
Connect the Measuring Instruments via the multi CPC jig (J-6082-
311-A).
The following table shows the Pin No. and signal name of the
connector.
[LCD type check]
By measuring the resistor value between Pin 6 of CN5502 and
Pin q; of CN5502, the type of LCD can be discriminated.
PD-156 board CN5502
Resistor
value
1 k
1.5 k
LCD type
TYPE S
TYPE C
Pin No.
1
3
5
7
9
Signal Name
VB
VG
VR
C-SYNC/XHD
GND
Pin No.
2
4
6
8
10
Signal Name
XVD OUT
PANEL COM
PANEL_ID
XHD OUT
GND
Fig. 5-1-16
1. VCO Adjustment (PD-156 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pin 8 of CN5502 (XHD OUT)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
A2, A3
Specified Value
f=15734 
±
 30 Hz (NTSC model)
f=15625 
±
 30 Hz (PAL model)
Note 1:
NTSC model: DCR-TRV140/TRV140M
PAL model: DCR-TRV140E
Adjusting method
Order Page Address Data
Procedure
1
0
01
01
2
D
A2
Change the data and set the
frequency (f) to the specified
value.
3
D
A2
Press PAUSE button.
4
D
A2
Read the data and this data is
named D
A2
.
5
Convert D
A2
 to decimal
notation, and obtain D
A2
’.
(Note 2)
6
Calculate D
A3
’ using
following equations.
(decimal calculation)
D
A3
’ = D
A2
’ + 23 (NTSC
model)
D
A3
’ = D
A2
’ – 20 (PAL model)
7
Convert D
A3
’ to a hexadeci-
mal number, and obtain D
A3
.
(Note 2, 3)
8
D
A3
D
A3
Press PAUSE button.
9
0
01
00
Note 2:
Refer to table 5-4-1. “Hexadecimal-decimal conver-
sion table”
Note 3:
If D
A3
’ > 255, then D
A3
 = FF (NTSC model)
If D
A3
’ < 0, then D
A3
 = 00 (PAL model)
Multi CPC jig
(J-6082-311-A)
PD-156 board
CN5502
6
 pin
0
 pin
Volt ohm meter
+
5-27
DCR-TRV140
3. Contrast Adjustment (PD-156 board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value. If deviated, the screen image will be blackish or satu-
rated (whitish).
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pin 3 of CN5502 (VG)
 External trigger : Pin 4 of CN5502
 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
AA
Specified Value
A=3.45 
±
 0.07 Vp-p (TYPE S model)
A=2.80 
±
 0.07 Vp-p (TYPE C model)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
AA
Change the data and set the
voltage (A) to the specified
value. (The data of address:
AA, should be “00” to “7F”)
3
D
AA
Press PAUSE button.
4
0
01
00
2. RGB AMP Adjustment (PD-156 board)
Set the D range of the RGB driver used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pin 3 of CN5502 (VG)
 External trigger : Pin 4 of CN5502
 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A5
Specified Value
A=3.60 
±
 0.05 Vp-p (TYPE S model)
A=2.90 
±
 0.05 Vp-p (TYPE C model)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
A5
Change the data and set the
voltage (A) to the specified
value. (The data of address:
A5, should be “00” to “3F”)
3
D
A5
Press PAUSE button
4
0
01
00
A: Between the pedestal (0 IRE) and 100 IRE
Fig. 5-1-18
A
2H 
100 IRE
Pedestal
A: Between the reversed waveform pedestal and
non-reversed waveform pedestal
Fig. 5-1-17
A
2H 
Pedestal 
Pedestal
5-28
DCR-TRV140
5. V-COM Adjustment (PD-156 board)
Set the DC bias of the common electrode drive signal of LCD to
the specified value.
If deviated, the LCD display will move, producing flicker and con-
spicuous vertical lines.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
A4
Note 1:
Perform “RGB AMP Adjustment”, ”Contrast
Adjsutment” and “COM AMP Adjustment” before this
Adjsutment.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
A4
Change the data so that
brightness of the section A
and section B is equal.
3
D
A4
Read the data and this data is
named Dref.
4
Convert Dref to decimal
notation, and obtain Dref’.
(Note 2)
5
Calculate D
A4
’ using
following equations.
(decimal calculation)
D
A4
’ = Dref’ - 8
6
Convert D
A4
’ to a hexadeci-
mal number, and obtain D
A4
.
(Note 2)
7
D
A4
D
A4
Press PAUSE button.
8
0
01
00
Note 2:
Refer to table 5-4-1. “Hexadecimal-decimal conversion
table”
4. COM AMP Adjustment (PD-156 board)
Set the common electrode drive signal level of LCD to the speci-
fied value.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Pin 4 of CN5502 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A7
Specified Value
NTSC model
A=6.30 
±
 0.05 Vp-p (TYPE S model)
A=5.45 
±
 0.05 Vp-p (TYPE C model)
PAL model
A=6.10 
±
 0.05 Vp-p (TYPE S model)
A=5.45 
±
 0.05 Vp-p (TYEP C model)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
A7
Change the data and set the
voltage (A) to the specified
value.
3
D
A7
Press PAUSE button.
4
0
01
00
A
A
A
A
B
B
B
B
Fig. 5-1-20
A: PANEL COM signal level
Fig. 5-1-19
A
2H
5-29
DCR-TRV140
6. White Balance Adjustment (PD-156 board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
A8, A9
Specified Value
The LCD screen should not be
colored.
Note 1:
Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5501
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
A8
80
Press PAUSE button.
A9
80
(Initial value)
3
Check that the LCD screen is
not colored. If not colored,
proceed to step 5.
4
D
A8
Change the data so that the
A9
LCD screen is not colored.
(Note 2)
5
0
01
00
Note 2:
To write in the non-volatile memory (EEPROM), press
the PAUSE button each time to set the data.
Page of 127
Display

Click on the first or last page to see other DCR-TRV140 service manuals if exist.