5. VIDEO OUT Y, Chroma Level Check (VC-256 Board)
Mode
VTR stop
Signal
No signal
Measurement Point
Video terminal of AUDIO/VIDEO jack
(75
 terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level: A = 286 ± 18mV (NTSC)
A = 300 ± 18mV (PAL)
Burst level: B = 286 ± 18mV (NTSC)
B = 300 ± 18mV (PAL)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
11
10
Set the data, and press PAUSE
button.
3
3
0C
02
Set the data, and press PAUSE
button.
4
Check that the sync signal level
(A) satisfies the specified value.
5
Check that the burst signal level
(B) satisfies the specified value.
6
3
0C
00
Set the data, and press PAUSE
button.
7
D
11
00
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
Fig. 5-3-10.
H
B
A
5-47
3-5.
IR TRANSMITTER ADJUSTMENTS
(DCR-TRV130)
Adjust using the IR receiver jig (J-6082-383-A).
Note:
If the distance between the IR receiver jig and the camcorder is
below 1m, cover the LASER LINK emitter with a ND filter. (For
example, when the distance is 30cm to 50cm, cover the LASER
LINK emitter with a ND filter 1.0.)
Switch setting:
SUPER LASER LINK ........................... ON (Red LED is lit)
1. IR Video Carrier Frequency Adjustment
(MI-041 Board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Pin 5 of CN003 of IR receiver jig (RF)
(Or Pin qh of IC3901 of MI-041 board)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
80
Specified Value
f = 11.85 ±  0.05 MHz (*1)
f = 11.55 ±  0.05 MHz (*2)
*1: IC3901 of MI-041 board is LA9511.
*2: IC3901 of MI-041 board is AN2920.
Connection of Equipment:
Connect the measuring device as shown in the following figure,
and adjust.
2. IR Video Deviation Adjustment (MI-041 Board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
VIDEO OUT terminal of IR receiver
jig (Terminated at 75
)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
7E
Specified Value
A = 0.82 ± 0.05 V
Connection of Equipment:
Connect the measuring device as shown in the following figure,
and adjust.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
08
Set the data, and press PAUSE
button.
3
F
80
Change the data, and set the
video carrier frequency (f) to the
specified value.
4
F
80
Press PAUSE button.
5
3
0C
00
Set the data, and press PAUSE
button.
6
0
01
00
Set the data.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
01
Set the data, and press PAUSE
button.
3
F
7E
Change the data, set the video
signal amplitude (A) to the
specified value.
4
F
7E
Press PAUSE button.
5
3
0C
00
Set the data, and press PAUSE
button.
6
0
01
00
Set the data.
Fig. 5-3-12.
Main unit
IR receiver jig
Pin 
5
 of 
CN003
Frequency counter
Main unit
IR receiver jig
VIDEO
OUT
75
75
 (1-247-804-11)
Oscilloscope
A
White
Fig. 5-3-11.
Fig. 5-3-13.
5-48
3. IR Audio Deviation Adjustment (MI-041 Board)
Mode
VTR stop
Signal
Video : Color bar, VIDEO IN jack of
DVMC-DA1
Audio : 400Hz, –7.5dBs, AUDIO IN
L and R jack of DVMC-DA1
Measurement Point
AUDIO L terminal and AUDIO R
terminal of IR receiver jig
(Terminated at 47k
)
Measuring Instrument
Audio level meter
Adjustment Page
F
Adjustment Address
7F
Specified Value
Signal level: –7.5 ± 1.0 dBs
Level difference of L and R: Below
2dB
Connection of Equipment:
Connect the measuring device as shown in the following figure,
and adjust.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Connect the audio level meter to
the AUDIO L terminal of the IR
receiver jig.
3
F
7F
Change the data and set the
400Hz audio signal level to the
specified value.
4
F
7F
Press PAUSE button.
5
Connect the audio level meter to
the AUDIO R terminal of the IR
receiver jig.
6
F
7F
Check that the 400Hz audio
signal level is within the
specified value. If outside, repeat
from step 2.
7
0
01
00
Set the data.
Main unit
Audio oscillator
Audio Left
(White)
DV 
IN/OUT
DV 
IN/OUT
R
L
VIDEO IN
VIDEO OUT
(75 
)
AUDIO IN
Audio Right
(Red)
Attenuator
Media converter
DVMC-DA1
Pattern generator
IR receiver jig
AUDIO OUT
L
R
Audio level meter
47k 
600 
600 
: 270 
 (1-249-410-11) + 330 
 (1-249-411-11)
47k 
 (1-249-437-11)
Fig. 5-3-14.
5-49
3-6.
AUDIO SYSTEM ADJUSTMENTS
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to the
video system measuring instruments as shown in Fig. 5-3-15.
1. Playback Level Check
Mode
Playback
Signal
Digital8 alignment tape:
  For audio operation check
  (WR5-3ND (NTSC), WR5-3CD (PAL))
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Audio level meter and frequency
counter
Specified Value
32 kHz mode: 1 kHz, +3.0 ± 2.0dBs
48 kHz mode: 1 kHz, +3.0 ± 2.0dBs
44.1 kHz mode:
The 7.35kHz signal level during EMP
OFF is +2.0 ± 2.0dBs.
The 7.35kHz signal level during EMP
ON is –6 ± 2 dB from the signal level
during EMP OFF.
Checking Method:
1)
Check that the playback signal level is the specified value.
Fig. 5-3-15.
Main unit
AUDIO/
VIDEO
Left (White)
Right 
47k 
47k 
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter 
47k 
 (1-249-437-11)
Playback
(Red)