5-46
5. VIDEO OUT Y, Chroma Level Check (VC-256 Board)
Mode
VTR stop
Signal
No signal
Measurement Point
Video terminal of AUDIO/VIDEO jack
(75
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level: A = 286 ± 18mV (NTSC)
A = 300 ± 18mV (PAL)
Burst level: B = 286 ± 18mV (NTSC)
B = 300 ± 18mV (PAL)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
11
10
Set the data, and press PAUSE
button.
button.
3
3
0C
02
Set the data, and press PAUSE
button.
button.
4
Check that the sync signal level
(A) satisfies the specified value.
(A) satisfies the specified value.
5
Check that the burst signal level
(B) satisfies the specified value.
(B) satisfies the specified value.
6
3
0C
00
Set the data, and press PAUSE
button.
button.
7
D
11
00
Set the data, and press PAUSE
button.
button.
8
0
01
00
Set the data.
Fig. 5-3-10.
H
B
A
5-47
3-5.
IR TRANSMITTER ADJUSTMENTS
(DCR-TRV130)
(DCR-TRV130)
Adjust using the IR receiver jig (J-6082-383-A).
Note:
If the distance between the IR receiver jig and the camcorder is
below 1m, cover the LASER LINK emitter with a ND filter. (For
example, when the distance is 30cm to 50cm, cover the LASER
LINK emitter with a ND filter 1.0.)
below 1m, cover the LASER LINK emitter with a ND filter. (For
example, when the distance is 30cm to 50cm, cover the LASER
LINK emitter with a ND filter 1.0.)
Switch setting:
SUPER LASER LINK ........................... ON (Red LED is lit)
1. IR Video Carrier Frequency Adjustment
(MI-041 Board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Pin 5 of CN003 of IR receiver jig (RF)
(Or Pin qh of IC3901 of MI-041 board)
(Or Pin qh of IC3901 of MI-041 board)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
80
Specified Value
f = 11.85 ± 0.05 MHz (*1)
f = 11.55 ± 0.05 MHz (*2)
f = 11.55 ± 0.05 MHz (*2)
*1: IC3901 of MI-041 board is LA9511.
*2: IC3901 of MI-041 board is AN2920.
*2: IC3901 of MI-041 board is AN2920.
Connection of Equipment:
Connect the measuring device as shown in the following figure,
and adjust.
Connect the measuring device as shown in the following figure,
and adjust.
2. IR Video Deviation Adjustment (MI-041 Board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
VIDEO OUT terminal of IR receiver
jig (Terminated at 75
jig (Terminated at 75
Ω
)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
7E
Specified Value
A = 0.82 ± 0.05 V
Connection of Equipment:
Connect the measuring device as shown in the following figure,
and adjust.
Connect the measuring device as shown in the following figure,
and adjust.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
08
Set the data, and press PAUSE
button.
button.
3
F
80
Change the data, and set the
video carrier frequency (f) to the
specified value.
video carrier frequency (f) to the
specified value.
4
F
80
Press PAUSE button.
5
3
0C
00
Set the data, and press PAUSE
button.
button.
6
0
01
00
Set the data.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
0C
01
Set the data, and press PAUSE
button.
button.
3
F
7E
Change the data, set the video
signal amplitude (A) to the
specified value.
signal amplitude (A) to the
specified value.
4
F
7E
Press PAUSE button.
5
3
0C
00
Set the data, and press PAUSE
button.
button.
6
0
01
00
Set the data.
Fig. 5-3-12.
Main unit
IR receiver jig
Pin
5
of
CN003
Frequency counter
Main unit
IR receiver jig
VIDEO
OUT
75
Ω
75
Ω
(1-247-804-11)
Oscilloscope
A
H
White
Fig. 5-3-11.
Fig. 5-3-13.
5-48
3. IR Audio Deviation Adjustment (MI-041 Board)
Mode
VTR stop
Signal
Video : Color bar, VIDEO IN jack of
DVMC-DA1
Audio : 400Hz, –7.5dBs, AUDIO IN
L and R jack of DVMC-DA1
Measurement Point
AUDIO L terminal and AUDIO R
terminal of IR receiver jig
(Terminated at 47k
terminal of IR receiver jig
(Terminated at 47k
Ω
)
Measuring Instrument
Audio level meter
Adjustment Page
F
Adjustment Address
7F
Specified Value
Signal level: –7.5 ± 1.0 dBs
Level difference of L and R: Below
2dB
Level difference of L and R: Below
2dB
Connection of Equipment:
Connect the measuring device as shown in the following figure,
and adjust.
Connect the measuring device as shown in the following figure,
and adjust.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Connect the audio level meter to
the AUDIO L terminal of the IR
receiver jig.
the AUDIO L terminal of the IR
receiver jig.
3
F
7F
Change the data and set the
400Hz audio signal level to the
specified value.
400Hz audio signal level to the
specified value.
4
F
7F
Press PAUSE button.
5
Connect the audio level meter to
the AUDIO R terminal of the IR
receiver jig.
the AUDIO R terminal of the IR
receiver jig.
6
F
7F
Check that the 400Hz audio
signal level is within the
specified value. If outside, repeat
from step 2.
signal level is within the
specified value. If outside, repeat
from step 2.
7
0
01
00
Set the data.
Main unit
Audio oscillator
Audio Left
(White)
(White)
DV
IN/OUT
IN/OUT
DV
IN/OUT
IN/OUT
R
L
VIDEO IN
VIDEO OUT
(75
(75
Ω
)
AUDIO IN
Audio Right
(Red)
(Red)
Attenuator
Media converter
DVMC-DA1
DVMC-DA1
Pattern generator
IR receiver jig
AUDIO OUT
L
R
Audio level meter
47k
Ω
600
Ω
600
Ω
: 270
Ω
(1-249-410-11) + 330
Ω
(1-249-411-11)
47k
Ω
(1-249-437-11)
Fig. 5-3-14.
5-49
3-6.
AUDIO SYSTEM ADJUSTMENTS
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to the
video system measuring instruments as shown in Fig. 5-3-15.
Connect the audio system measuring instruments in addition to the
video system measuring instruments as shown in Fig. 5-3-15.
1. Playback Level Check
Mode
Playback
Signal
Digital8 alignment tape:
For audio operation check
(WR5-3ND (NTSC), WR5-3CD (PAL))
For audio operation check
(WR5-3ND (NTSC), WR5-3CD (PAL))
Measurement Point
AUDIO/VIDEO jack left or right
Measuring Instrument
Audio level meter and frequency
counter
counter
Specified Value
32 kHz mode: 1 kHz, +3.0 ± 2.0dBs
48 kHz mode: 1 kHz, +3.0 ± 2.0dBs
44.1 kHz mode:
The 7.35kHz signal level during EMP
OFF is +2.0 ± 2.0dBs.
The 7.35kHz signal level during EMP
ON is –6 ± 2 dB from the signal level
during EMP OFF.
48 kHz mode: 1 kHz, +3.0 ± 2.0dBs
44.1 kHz mode:
The 7.35kHz signal level during EMP
OFF is +2.0 ± 2.0dBs.
The 7.35kHz signal level during EMP
ON is –6 ± 2 dB from the signal level
during EMP OFF.
Checking Method:
1)
1)
Check that the playback signal level is the specified value.
Fig. 5-3-15.
Main unit
AUDIO/
VIDEO
Left (White)
Right
47k
Ω
47k
Ω
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k
Ω
(1-249-437-11)
Playback
(Red)