DOWNLOAD Sony DCR-SC100 / DCR-SC100E Service Manual ↓ Size: 4.09 MB | Pages: 121 in PDF or view online for FREE

Model
DCR-SC100 DCR-SC100E
Pages
121
Size
4.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M DCR-SC100/SC100E''97 US AEP
File
dcr-sc100-dcr-sc100e.pdf
Date

Sony DCR-SC100 / DCR-SC100E Service Manual ▷ View online

5–49
PD-87 BOARD (SIDE A)
CN1401
1
9
VC-193 BOARD (SIDE A)
NOTE: IC201 and IC8401 are mounted to the SIDE B.
IC1900
IC402
CN201
IC201
IC8401
CN9301
CN9304
CN9303
R1901
11
1
39
2
40
1
10
20
1
2
79
80
1
5
1
12
13
24
25
36
37
48
1
12
13
24
25
36
37
48
1
2
13
14
5–53
0 : 00 : 00
Page
Data Address
Fig. 5-4-1.
3) Operate the adjusting remote commander as follows.
• Changing the page
The page increases when the EDIT SEARCH+ button is pressed,
and decreases when the EDIT SEARCH– button is pressed.
There are altogether 16 pages, from 0 to F.
Table 5-4-1.
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 11 12 13 1415
0 1 2 3 4 5 6 7 8 9 A B C D E F
• Changing the address
The address increases when the FF (
)) button is pressed,
and decreases when the REW (
0) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (
() button is pressed, and
decreases when the STOP (
p) button is pressed.
There are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data (C, D, F page) in the nonvolatile memory.
(The new adjustment data will not be recorded in the nonvolatile
memory if this step is not performed.)
4) After completing all adjustments, turn off the main power supply
(8.4V) once.
5-4. SERVICE MODE
4-1. ADJUSTING REMOTE COMMANDER
The adjusting remote commander is used for changing the calculation
coefficient in signal processing, EVR data, etc. The adjusting
remote commander performs bi-directional communication with
the unit using the remote commander signal line (LANC). The
resultant data of this bi-directional communication is written in
the non-volatile memory.
1. Using the adjusting remote commander
1) Connect the adjusting remote commander to the LANC terminal.
2) Adjust the HOLD switch of the adjusting remote commander to
“HOLD” (SERVICE position).
If it has been properly connected, the LCD on the adjusting
remote commander will display as shown in Fig. 5-4-1.
2. Precautions upon using the adjusting
remote commander
Mishandling of the adjusting remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjustments
and new adjustment data after each adjustment.
5–54
4-2. DATA PROCESSING
The calculation of the DDS display and the adjusting remote
commander display data (hexadecimal notation) are required for
obtaining the adjustment data of some adjustment items. In this case,
after converting the hexadecimal notation to decimal notation,
calculate and convert the result to hexadecimal notation, and use it
as the adjustment data. Table 5-4-2. indicates the hexadecimal
notation-the decimal notation calculation table.
Table 5-4-2.
Hexadecimal notation-Decimal notation
2
The lower digits of the
hexadecimal notation
The upper digits of the
hexadecimal notation
0
1
2
3
4
5
6
7
8
9
A (
A)
B (
b)
C (
c)
D (
d)
E (
E)
F (
F)
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
(
A)
(
b)
(
c)
(
d)
(
E)
(
F)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
104
165
166
167
168
109
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
Note:
(
) indicate the adjusting remote control unit display.
(Example) In the case that the DDS display and the adjusting remote control unit display are BD (
bd).
As the upper digit of the hexadecimal notation is B (
b), and the lower digit is D (d), the intersection “189”  of the 1
and 2 in the above table is the decimal notation to be calculated. conversion table
5–55
4-3. SERVICE MODE
1.
Setting the Test Mode
For page D, the data set is recorded in the non-volatile memory
by pressing the PAUSE button of the adjusting remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off (8.4 Vdc).
After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjusting
remote commander.
Set data: 00 to page: 0, address: 01.
2. Record of Use Check
Page D
Address 10
Function
Normal
Forced camera power ON
Forced VTR power ON
Forced camera+VTR power ON
Data
00
01
02
03
Page 2
Address 35 to 3D
Using method:
1) The record of use data is displayed at addresses: 35 to 3D of
page 2.
Note: This data will be erased (reset) when the vanadium lithium
battery (LI-62 board BT701) is removed.
Address
35
36
37
38
39
3A
3B
3C
3D
Drum rotation
counted time
(decimal)
User initial power on
date
(decimal)
Final condensation
occurrence date
(decimal)
Function
Minute
Hour (L)
Hour (H)
Year
Month
Day
Year
Month
Day
Remarks
1 to 59 minutes
1 to 99 hours
100 to 9900 hours
After setting the clock, set the date of power on next
Page of 121
Display

Click on the first or last page to see other DCR-SC100 / DCR-SC100E service manuals if exist.