DOWNLOAD Sony DCR-SC100 / DCR-SC100E Service Manual ↓ Size: 4.09 MB | Pages: 121 in PDF or view online for FREE

Model
DCR-SC100 DCR-SC100E
Pages
121
Size
4.09 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M DCR-SC100/SC100E''97 US AEP
File
dcr-sc100-dcr-sc100e.pdf
Date

Sony DCR-SC100 / DCR-SC100E Service Manual ▷ View online

5–11
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 200 ± 50 lux)
Check operations on TV monitor
F
24 to 29, 38 to 3C
20) Press the PAUSE button of the adjusting remote commander.
21) Set data: 03 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
22) Read the DDS display data, and this data is named W
0
. If W
0
lies within the “8C” to “90” range, perform “Processing after
completing adjustments”. If it lies outside the range, perform
the following adjustments.
23) Convert W
0
 to decimal notation, and obtain W
0
´.
24) Calculate X
2
´ using the following equations (decimal notation
calculation).
C´ = W
0
´ – B´ – 24 ................................................... Equation 4
X
2
´= ............... Equation 
5
(X
1
´ and B´ are values obtained from equations 2) and 3)
25) Convert X
2
´ to hexadecimal notation and obtain X
2
.
(Round off to one decimal place)
26) Set data X
2
 to page: F, address: 1E, and press the PAUSE button
of the adjusting remote commander.
27) Change the data of page: F, address: 1F, and adjust the DDS
display data to “8E”.
28) Press the PAUSE button of the adjusting remote commander.
29) Set data: 01 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
30) Check that the DDS display data lies within the “16” to “1A”
range.
Processing after Completing Adjustments
1) Set data: 00 to page: D, address: 11, and press the PAUSE button
of the adjusting remote commander.
2) Set data: 00 to page: 0, address: 01.
3) Set data: 00 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
4) Set data: 00 to page: 6, address: 04.
5) Set data: 00 to page: 6, address: 00.
4) Check that the data of page: 6, address: 02 is 00.
5) Set data: 13 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
6) Set data: 15 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
(The adjustment data will be automatically input to page: F,
address: 24 to 29, 38 to 3C.)
7) Check that the data of page: 6, address: 02 is “01”.
Processing after Completing Adjustments
1) Turn OFF the main power supply (8.4V)
Adjusting method:
1) Check that at both the zoom lens TELE terminal and WIDE
terminal, the center of the chart for the flange back adjustment
and center of the exposure screen coincide.
2) Set data: 01 to page: 6, address: 00.
3) Check that the data of page: F, address: 24 to 29, 38 to 3C is the
initial value (see table below).
5. Flange Back Adjustment
The inner focus lens flange back adjustment is carried out
automatically.
(118 – B´) x (X
1
´ – 48) + 48 x C´
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Address
Data
CD
19
92
21
12
14
24
25
26
27
28
29
41
00
19
00
2E
38
39
3A
3B
3C
Address
Data
5–12
6. Flange Back Check
Siemens star
2.0m from the front of the lens
Luminance: approx. 200 lux
Check the operation on the TV monitor
Focused at the TELE end and WIDE end.
Subject
Measurement Point
Measuring Instrument
Specified Value
Color bar chart standard picture frame
(1.5m from the front of the lens)
Video output terminal of AUDIO VIDEO
OUT jack
Oscilloscope and TV monitor.
A = B, C = D, t = 0 ± 0.1 msec
Subject
Measurement Point
Measuring Instrument
Specified Value
Check on the oscilloscope
1. horizontal period
A = B
A
B
C = D
C
D
2. Vertical period
V
t = 0 ± 0.1 msec
Check on the TV monitor
Color bar chart picture frame
TV monitor picture frame
Fig. 5-1-6.
Fig. 5-1-7.
Fig. 5-1-8.
7. Picture Frame Setting
Setting method:
1) Adjust the zoom and the camera direction, and set to the specified
position.
2) Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “color bar chart standard picture frame”.
n
Switch setting:
1) STEADY SHOT (Menu display) ....................................... OFF
2) DIGITAL ZOOM (Menu display) ...................................... OFF
Checking method:
1) Place the Siemens star 2.0m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Siemens
star up to a point before noise appears on the image.
3) Shoot the siemens star with the zoom TELE end.
4) Turn on the auto focus.
5) Check that the lens is focused (Note 1), and turn off the auto
focus
6) Set data: 10 to page: 6, address: 21.
7) Shoot the siemens star with the zoom WIDE end.
8) Observe the TV monitor and check that the lens is focused.
Note 1: When the auto focus is ON, the lens can be checked if it is
focused or not by observing the data on page A of the
adjusting remote commander.
1) Set data: 0F to page: 6, address: 04.
2) Page A shows the state of the focus.
A : 00 : XX
01: Focused
00: Unfocused
Processing after Completing Adjustments
1) Set data: 00 to page: 6, address: 21.
2) Set data: 00 to page: 6, address: 04.
5–13
8. G-CAM flip Discrimination Adjustment
Sets the color reproduction conditions to optimum.
Note 1: Displayed data of page A of the adjusting remote
commander
A : XX : XX
S2
S1
Adjusting method
1) Set data: 01 to page: 6, address: 00.
2) Set data: 01 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
3) Set data: 16 to page: 6, address: 04.
4) Set data: 59 (NTSC) or data: 70 (PAL) to page: F, address: 53,
and press the PAUSE button of the adjusting remote commander.
5) Select page A of the adjusting remote commander, and compare
the higher 2 digits (S1) and lower 2 digits (S2) of the 4-digit
display data.
[When S1<S2]
Perform steps 6) onwards.
[When S1
<
=
S2]
Perform steps 7) onwards.
6) Set data: D9 (NTSC) or data: F0 (PAL) to page: F, address: 53,
and press the PAUSE button of the adjusting remote commander.
7) Set data: 00 to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
8) Set data: 00 to page: 6, address: 04.
9) Set data: 00 to page: 6, address: 00.
Color bar chart standard picture frame
Display data of page A of the adjusting
remote commander (Note 1)
F
53
Subject
Measuring point
Measuring instrument
Adjusting page
Adjusting address
n
n
5–14
Color bar chart standard picture frame
Video output terminal of AUDIO /
VIDEO OUT jack
Vectorscope
F
2E, 30, 8F, 90
All color luminance points should settle
within each color reproduction frame.
9. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that the proper color
reproduction is produced.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: NTSC model: DCR-SC100
PAL model: DCR-SC100E
Adjusting method:
1) Set data: 01 to page: 6, address: 00.
2) Set data: 3D to page: 6, address: 01, and press the PAUSE button
of the adjusting remote commander.
3) Set data: 3F to page: F, address: 16, and press the PAUSE button
of the adjusting remote commander.
4) Adjust the GAIN and PHASE of the vectorscope, and adjust the
burst luminance point to the burst position of the color
reproduction frame.
5) Change the data of addresses 2E, 30, 8F and 90 of page: F, and
settle each color luminance point in each color reproduction
frame.
Note 1: Be sure to press the PAUSE button of the adjusting
remote commander before changing the addresses.
If not, the new data will not be written to the memory.
6) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments
1) Set data: 00 to page: 6, address: 01 and press the PAUSE button
of the adjusting remote commander.
2) Set data: 00 to page: 6, address: 00.
For NTSC model
Fig. 5-1-9.
For PAL model
Fig. 5-1-10.
(
Burst position
Burst position
(
Page of 121
Display