Sony DCR-PC8E (serv.man2) Service Manual ▷ View online

5-45
DCR-PC8E
5. PLL f
0
 & LPF f
0
 Fine Adjustment (VC-265D board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
30
Set the data, and press PAUSE
button.
3
3
02
Check that the data changes to
“00” with in 5 sec. (Note1)
4
3
03
Check that the data is “00”.
(Note2)
5
0
01
00
Set the data.
Note1:
If it isn’t satisfied, there are errors.
Note2:
If the data of page: 3, address: 03 is other than “00”, there are
errors. For the error contents, see the following table. (For the bit
values, refer to “5-4. SERVICE MODE”,  “4-3. 3. Bit value
discrimination”.)
Bit value of page: 3,
Error contents
address: 03 data
bit 2 = 1 or bit 3 = 1
PLL f
0
 fine adjustment is defective
bit 4 = 1 or bit 5 = 1
PLL f
0
 adjustment is defective
bit 6 = 1
LPF f
0
 is defective
4-4. Processing after Completing Adjustments
Order Page Address Data
Procedure
1
2
30
00
Set the data.
2
3
33
00
Set the data.
3
0
01
00
Set the data.
5-46
DCR-PC8E
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the
specified value of “36MHz Origin Oscillation Adjustment” of
“CAMERA SYSTEM ADJUSTMENT” is satisfied.
1. Chroma BPF f
0
 Adjustment (VC-265D board)
Set the center frequency of IC801 chroma band-pass filter.
Mode
Camera
Subject
All black
(Cover the lens with the lens cap)
Measurement Point
CH1: Chroma signal terminal of
S VIDEO jack (75
 terminated)
CH2: Y signal terminal of S VIDEO
jack (75
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
28
Specified Value
A = 100mVp-p or less
B = 200mVp-p or more
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Check that the burst signal (B) is
output to the chroma signal
terminal of S VIDEO jack.
3
3
0C
04
Set the data, and press PAUSE
button.
4
C
28
Change the data for minimum
amplitude of the burst signal
level (A).
(The data should be “00” to
“0F”.)
5
C
28
Press PAUSE button.
6
3
0C
00
Set the data, and press PAUSE
button.
7
Check that the burst signal level
(B) satisfies the specified value.
8
0
01
00
Set the data.
2. S VIDEO OUT Y Level Adjustment (VC-265D board)
Mode
Camera
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO jack
(75
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified Value
A = 1000 ± 14mV
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
35
Note down the data.
3
2
35
01
Set the data.
4
3
0C
02
Set the data, and press PAUSE
button.
5
C
25
Change the data and set the Y
signal level (A) to the specified
value.
6
C
25
Press PAUSE button.
7
3
0C
00
Set the data, and press PAUSE
button.
8
2
35
Set the data that is noted down at
step 2.
9
0
01
00
Set the data.
CH1
CH2
A
H
CH1
H
B
When the data of page: 3, address: 0C, is 04:
When the data of page: 3, address: 0C, is 00:
Fig. 5-3-8.
H
Center of luminance line
A
Fig. 5-3-9.
5-47
DCR-PC8E
3. S VIDEO OUT Chroma Level Adjustment
(VC-265D board)
Mode
Camera
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
jack (75
 terminated)
External trigger: Y signal terminal of
S VIDEO jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified Value
Cr level:
A = 700 ± 14mV
Cb level:
B = 700 ± 14mV
Burst level: C = 300 ± 6mV
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
35
Note down the data.
3
2
35
01
Set the data.
4
3
0C
02
Set the data, and press PAUSE
button.
5
C
26
Change the data and set the Cr
signal level (A) to the specified
value.
6
C
26
Press PAUSE button.
7
C
27
Change the data and set the Cb
signal level (B) to the specified
value.
8
C
27
Press PAUSE button.
9
Check that the burst signal level
(C) is satisfied the specified value.
10
3
0C
00
Set the data, and press PAUSE
button.
11
2
35
Set the data that is noted down at
step 2.
12
0
01
00
Set the data.
4. VIDEO OUT Y, Chroma Level Check (VC-265D board)
Mode
Camera
Subject
Arbitrary
Measurement Point
VIDEO terminal of AUDIO/VIDEO
jack (75
 terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level: A = 300 ± 18mV
Burst level: B = 300 ± 18mV
Adjusting method:
Order Page Address Data
Procedure
1
2
35
Note down the data.
2
2
35
01
Set the data.
3
3
0C
02
Set the data, and press PAUSE
button.
4
Check that the sync signal level
(A) satisfies the specified value.
5
Check that the burst signal level
(B) satisfies the specified value.
6
3
0C
00
Set the data, and press PAUSE
button.
7
2
35
Set the data that is noted down at
step 1.
8
0
01
00
Set the data.
H
C
A
0.23 
µ
sec
B
0.23 
µ
sec
H
B
A
Fig. 5-3-10.
Fig. 5-3-11.
5-48
DCR-PC8E
3-5.
AUDIO SYSTEM ADJUSTMENTS
[Connection of Audio System Measuring Devices]
Connect the audio system measuring devices as shown in Fig. 5-3-12.
Fig. 5-3-12.
Recording (Camera mode)
Audio oscillator
Attenuator
600 
Left
Right
Main unit
MIC
600 
: 270 
 (1-249-410-11) + 330 
 (1-249-411-11)
Main unit
AUDIO/
VIDEO
OUT
Left (White)
Right 
47k 
47k 
Video (Yellow)
TV monitor
Audio level meter
or Distortion meter
47k 
 (1-249-437-11)
Playback
(Red)
Page of 119
Display