DOWNLOAD Sony DCR-PC8E (serv.man2) Service Manual ↓ Size: 4.69 MB | Pages: 119 in PDF or view online for FREE

Model
DCR-PC8E (serv.man2)
Pages
119
Size
4.69 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-pc8e-sm2.pdf
Date

Sony DCR-PC8E (serv.man2) Service Manual ▷ View online

5-33
DCR-PC8E
8. White Balance Adjustment (PD-148A board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
A8, A9
Specified Value
The LCD screen should not be colored.
Note1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC2101
Note2:
Use the AC power adaptor.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
A8
79
Set the data, and press PAUSE
button.
3
D
A9
6F
Set the data, and press PAUSE
button.
4
D
A9
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5
D
A8
Change the data so that the LCD
screen is not colored.
6
D
A8
Press PAUSE button.
7
D
A9
Change the data so that the LCD
screen is not colored.
8
D
A9
Press PAUSE button.
9
D
A9
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
5-34
DCR-PC8E
5-2. MECHANISM SECTION
ADJUSTMENT
On the mechanism section adjustment
For details of mechanism section adjustments, checks,
and replacement of mechanism parts, refer to the separate
volume “DV MECHANICAL ADJUSTMENT MANUAL 
J Mechanism  ”.
2-1.
HOW TO ENTER RECORD MODE WITHOUT
CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, set data: 0C, and press the PAUSE
button of the adjustment remote commander.
(The mechanism enters the record mode automatically.)
Note:
The function buttons become inoperable.
5)
To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander.  (Whenever you want to quit the record mode, be
sure to quit following this procedure.)
2-2.
HOW TO ENTER PLAYBACK MODE
WITHOUT CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, set data: 0B, and press the PAUSE
button of the adjustment remote commander.
(The mechanism enters the playback mode automatically.)
Note:
The function buttons become inoperable.
5)
To quit the playback mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander.  (Whenever you want to quit the playback mode,
be sure to quit following this procedure.)
2-3.
TAPE PATH ADJUSTMENT
1. Preparation for Adjustment
1)
Clean the tape running side (tape guide, drum, capstan shaft,
pinch roller, etc.).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
4)
Connect an oscilloscope to VC-265D board CN004 via the
CPC-6 flexible jig (J-6082-370-B) and CPC-6 terminal board
jig (J-6082-371-A).
Channel 1: VC-265D board, CN004 Pin w; (Note)
External trigger: VC-265D board, CN004 Pin qj
Note:
Connect a 75 
 resistor between pins w; of CN004 and ql
(GND).
75 
 resistor (Parts code: 1-247-804-11)
5)
Playback the alignment tape for tracking. (XH2-1)
6)
Select page: 3, address: 33, and set data: 08.
7)
Select page: 3, address: 26, and set data: 31.
8)
Check that the oscilloscope RF waveform is normal at the
entrance and exit.
If not normal, adjust according to the separate volume
“DV MECHANICAL ADJUSTMENT MANUAL 
J Mechanism ” .
CN004 of VC-265D board
2. Procedure after operations
1)
Connect the adjustment remote commander to the LANC jack
and set the HOLD switch to the ON position.
2)
Select page: 3, address: 26, and set data: 00.
3)
Select page: 3, address: 33, and set data: 00.
Fig. 5-2-1.
CH1
Entrance side
Exit side
Check this section
(Normal waveform)
CH2
(Trigger)
3.3msec
Pin No.
1
3
5
7
9
11
13
15
17
19
Signal Name
LANC SIG
EVF LED DA
EVF VCO
TW PWE
HI RXD
HI TEST A
TCK
JIG TDO
SWP
GND
Pin No.
2
4
6
8
10
12
14
16
18
20
Signal Name
EVF VG
GND
HI XRESET
HI TXD
TMS
JIG TDI
GND
RF IN/LANC JACK IN
RF MON
5-35
DCR-PC8E
5-3. VIDEO SECTION ADJUSTMENTS
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1.
Equipment Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band above 30 MHz with
delay mode) (Unless specified otherwise, use a 10 : 1 probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal.
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) Alignment tapes
• Tracking standard (XH2-1)
Parts code: 8-967-997-01
• SW/OL standard (XH2-3)
Parts code: 8-967-997-11
• Audio operation check for PAL (XH5-3P)
Parts code: 8-967-997-55
• System operation check for PAL (XH5-5P)
Parts code: 8-967-997-66
12) Adjustment remote commander (J-6082-053-B)
13) CPC-6 flexible jig (J-6082-370-B) (Note)
14) CPC-6 terminal board jig (J-6082-371-A)
Note:
When using the old CPC-6 jig (J-6082-370-A), open the cabinet
(R) assembly.
5-36
DCR-PC8E
3-1-2.
Precautions on Adjusting
1)
The adjustments of this unit are performed in the VTR mode
or camera mode.
To set to the VTR mode, set the power switch to “VCR” or set
the “Forced VTR Power ON mode” using the adjustment remote
commander (Note 1).
To set to the Camera mode, set the power switch to “CAMERA”
or set the “Forced Camera Power ON mode” using the
adjustment remote commander (Note 2).
After completing adjustments, be sure to exit the “Forced VTR
Power ON Mode” or “Forced Camera Power ON Mode”.
2)
To remove the cabinet (R), disconnect the following connector.
VC-265D board CN012 (60P, 0.4mm)
As the DC IN jack is connected to the BJ-002A board of the
cabinet (R), the board must be connected to the VC-265D board.
So remove the BJ-002A board and DC IN jack from the cabinet
(R). To remove them from the cabinet (R), disconnect the
following connectors. (The LCD block and battery terminal
need not to be connected. To operate VTR, use the adjustment
remote commander.)
1. BJ-002A board CN3107 (8P, 0.8mm)
2. BJ-002A board CN3106 (16P, 0.8mm)
3. BJ-002A board CN3105 (3P, 1.5mm)
And connect the BJ-002A board to the following connector of
VC-265D board.
VC-265D board CN012 (60P, 0.4mm)
3)
The Lens-EVF block need not to be connected. To remove them,
disconnect the following connector.
VC-265D board CN001 (88P, 0.4mm)
4)
As removing CN013 0f  VC-265D board (removing the control
switch block (FK-1770)) means removing the lithium 3V power
supply, data such as date, time, user-set menus will be lost.
After completing adjustments, reset these data. If the CN013
has been removed, the self-diagnosis data, data on history of
use (total drum rotation time etc.) will be lost. Before removing,
note down the self-diagnosis data (data of page: 2, address: B0
to C6) and the data on history use (data of page: 2, address: A2
to AA). (Refer to “5-4.Service Mode” for the data on the history
use and the self-diagnosis data.)
5)
If the “Forced VTR power ON” mode is set, the control switch
block (PS-1770) need not be connected. To remove it,
disconnect the following connectors.
Control switch block (FK-1770) CN602 (8P, 0.5mm)
Note 1:
Setting the “Forced VTR Power ON” mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the VTR power to be turned on
with the control switch block (PS-1770) removed.
After completing adjustments, be sure to exit the “Forced Power
ON mode”.
Note 2:
Setting the “Forced Camera Power ON” mode (Camera mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (PS-1770) removed.
After completing adjustments, be sure to exit the “Forced Power
ON mode”.
Note 3:  
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Page of 119
Display