DOWNLOAD Sony DCR-PC106E / DCR-PC107E (serv.man4) Service Manual ↓ Size: 1.18 MB | Pages: 59 in PDF or view online for FREE

Model
DCR-PC106E DCR-PC107E (serv.man4)
Pages
59
Size
1.18 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc106e-dcr-pc107e-sm4.pdf
Date

Sony DCR-PC106E / DCR-PC107E (serv.man4) Service Manual ▷ View online

6-15
DCR-PC106E/PC107E
3. E Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Table. 6-1-7.
Address
00 to 14
15
16 to 1B
1C
1D
1E to 34
35
36 to 3B
3C
3D to 42
43
44
45
46
47
48
49
4A
4B
4C
4D to 86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92 to C3
C4
C5 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
4. F Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C to 29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36 to 39
3A
3B
3C to 3D
3E
3F
40
41
42 to 43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
80
45
43
11
20
02
E0
A8
00
60
1B
00
07
00
0E
00
0D
00
22
24
00
EF
2C
40
59
30
1F
F6
27
DD
14
4B
00
00
00
00
22
19
00
75
36MHz origin osc. adj.
Fixed data-1
HALL adj.
Fixed data-1
MAX GAIN adj.
LV standard data input
Fixed data-1
AWB standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Auto white balance adj.
Fixed data-1
Flange back adj.
6-16
DCR-PC106E/PC107E
F page
Address
Address
Remark
Initial value
52
53
54
56 to 59
5A
5B to 8B
8C
8D
8E
8F
90
91 to 92
93
94
95
96
97
98
99
9A
9B
9C
9D to 9F
A0
A1
A2
A3
A4
A5
A6
A7 to A8
A9
AA
AB
AC
AD
AE
AF
B0
B1 to CB
CC
CD
CE
CF
D0
D1
D2
D3 to EA
EB
EC to ED
EE
EF to F1
F2
F3
Remark
Initial value
04
00
00
FF
Flange back adj.
Fixed data-1
Optical axis adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Table. 6-1-9.
Address
Remark
Initial value
Address
Remark
Initial value
F4 to F8
F9
FA to FB
FC
FD to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-17
DCR-PC106E/PC107E
5. 1F Page Table
Note1: When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 1F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1F Page Data”).
Table. 6-1-9.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 59
5A
5B
5C
5D
A9 to FF
00
00
00
00
Fixed data-1
Emergency memory address
(Camera section)
Fixed data-1
6-18
DCR-PC106E/PC107E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “36MHz
Origin Oscillation Adjustment”), check that the specified values of
“VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 36MHz Origin Oscillation Adjustment (VC-350 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin qs of IC3001
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f=18000000 
±
 90Hz
Note: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
VC-350 board
IC3001
1
12
36
25
13
24
48
37
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
12 to 17
Specified Value 1
85 to 89
Specified Value 2
15 to 19
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
87
Set the data.
3
6
95
17
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note4)
6
6
01
00
Set the data, and press PAUSE
button.
Note4: The adjustment data will be automatically input to page: F, address:
12 to 17.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
Fig. 6-1-6.
Page of 59
Display

Click on the first or last page to see other DCR-PC106E / DCR-PC107E (serv.man4) service manuals if exist.