DOWNLOAD Sony DCR-HC65 (serv.man2) Service Manual ↓ Size: 5.37 MB | Pages: 67 in PDF or view online for FREE

Model
DCR-HC65 (serv.man2)
Pages
67
Size
5.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-hc65-sm2.pdf
Date

Sony DCR-HC65 (serv.man2) Service Manual ▷ View online

1-1
SECTION 1
SERVICE NOTE
DCR-HC65
Make sure that the flat cable and flexible board are not cracked of 
bent at the terminal.
Do not insert the cable insufficiently nor crookedly.
Cut and remove the part of gilt 
which comes off at the point.
(Take care that there are 
some pieces of gilt left inside)
When remove a connector, don't pull at wire of connector.
Be in danger of the snapping of a wire.
When installing a connector, don't press down at wire of connector.
Be in danger of the snapping of a wire.
1-1. SERVICE NOTE
1.
NOTE FOR REPAIR
1-2
DCR-HC65
2.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied to the battery terminal using the regulated power supply (8.4V), the power is shut off so
that the unit cannot operate.
This following two methods are available to prevent this. Take note of which to use during repairs.
Method 1.
Use the AC power adaptor (AC-L25).
Method 2.
Connect the servicing remote commander RM-95 (J-6082-053-B) to the LANC jack, and set the commander switch to the “ADJ” side.
3.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
1
Open the flash.
2
Remove the cabinet (F) section.
3
Remove the cabinet (R) section.
4
Remove the EVF section.
5
Remove the VC-359 board.
6
Remove the mechanism deck.
7
Supply +4.5V from the DC power supply to the loading motor and unload with pressing the cassette compartment.
VC-359
VC-359 board
DC power supply (+4.5Vdc)
Loading motor
1-3
DCR-HC65
1-2. SELF-DIAGNOSIS FUNCTION
1.
SELF-DIAGNOSIS FUNCTION
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder, or LCD
screen what to do.
Details of the self-diagnosis functions are provided in the Instruction
manual.
2.
SELF-DIAGNOSIS DISPLAY
When problems occur while the unit is operating, the counter of the
viewfinder or LCD screen consists of an alphabet and 4-digit number,
which blinks at 3.2Hz. This 5-character display indicates the
“repaired by:”, “block” in which the problem occurred, and “detailed
code” of the problem.
Note: The “self-diagnosis display” data will be kept even if the lithium battery (BT151 of CK-141 board) is removed.
1 1
3 1
C
Repaired by:
Refer to page 1-4.
Self-diagnosis Code Table.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
Ver 1.1  2004. 07
1-4E
DCR-HC65
3.
SELF-DIAGNOSIS CODE TABLE
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
E
E
E
E
E
Block
Function
0
4
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
2
0
6
1
6
1
6
2
6
2
Detailed
Code
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
0
0
0
0
1
0
0
0
0
1
Symptom/State
Non-standard battery is used.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
Winding S reel fault when counting the
rest of tape.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum operations.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
S reel side tape slacking when
unloading.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum
FG fault during normal drum
operations
Data on A page or D page are rewriten.
Difficult to adjust focus
(Cannot initialize focus.)
Zoom operations fault
(Cannot initialize zoom lens.)
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Self-diagnosis Code
Repaired b
y
:
Correction
Use the info LITHIUM battery.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Make data on A page and D page correct value.
Inspect the lens block focus MR sensor (Pin 1, 2 of CN5101 of
VC-359 board) when focusing is performed when the focus ring is
rotated in the focus manual mode, and the focus motor drive circuit
(IC5101 of VC-359 board) when the focusing is not performed.
Inspect the lens block zoom reset sensor (Pin  wh of CN5101 of
VC-359 board) when zooming is performed when the zoom switch
is operated and the zoom motor drive circuit (IC5101 of VC-359
board) when zooming is not performed.
Inspect pitch angular velocity sensor (SE401 of CD-513 board)
peripheral circuits.
Inspect yaw angular velocity sensor (SE402 of CD-513 board)
peripheral circuits.
Ver 1.1  2004. 07
Page of 67