Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc51e-dcr-hc52-dcr-hc52e-dcr-hc53e-dcr-hc54-dc.pdf
Date

Sony DCR-HC51E / DCR-HC52 / DCR-HC52E / DCR-HC53E / DCR-HC54 / DCR-HC54E (serv.man4) Service Manual ▷ View online

6-44
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
3.
VIDEO OUT Level Check (VC-537 board)
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Video terminal of A/V OUT jack (75
Ω terminated)
Measuring Instrument
Oscilloscope
Specified value
Sync level: A = 286 
± 18 mVp-p (NTSC)
A = 300 
± 18 mVp-p (PAL)
Burst level: B = 286 
± 18 mVp-p (NTSC)
B = 300 
± 18 mVp-p (PAL)
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: NTSC model: DCR-HC52/HC54
PAL model: DCR-HC51E/HC52E/HC53E/HC54E
Switch setting:
1) DEMO MODE (Menu setting) ........................................ OFF
Checking method:
Order Page Address Data
Procedure
1
3
0C
02
Press PAUSE (Write) button.
2
Check the sync signal level
(A) to the specified value.
3
Check the burst signal level
(B) to the specified value.
4
3
0C
00
Press PAUSE (Write) button.
Fig. 6-3-5
H
B
A
6-45
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
3-5.
AUDIO  SYSTEM  ADJUSTMENTS
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to
the video system measuring instruments as shown in Fig. 6-3-6.
Fig. 6-3-6
Audio
oscillator
Attenuator
600 Ω
600 Ω (270 Ω (1-249-410-11) +330 Ω (1-249-411-11))
Main unit
Main unit
47 k Ω
47 k Ω: 1-249-437-11
Audio level meter or
distortion meter
TV monitor
A/V R
 jack
Pattern generator 
Video output
 (75 Ω)
A/V R
jack
(L)
(R)
Video
Audio (L)
Audio (R)
In Recording (CAMERA mode)
In Playback (PLAY/EDIT mode)
Audio
Video
Audio
1.
Playback Level Check
Mode
Playback (PLAY/EDIT mode)
Signal
Alignment tape:
For audio operation check
(XH5-3 (NTSC))
(XH5-3P (PAL))
Measurement Point
Audio left or right terminal of A/V R
jack
Measuring Instrument
Audio level meter and frequency
counter
Specified Value
32 kHz mode: 1 kHz, + 3.0 
± 2.0 dBs
48 kHz mode: 1 kHz, + 3.0 
± 2.0 dBs
44.1 kHz mode:
The 7.35 kHz signal level during EMP
OFF is +2.0 
± 2.0 dBs.
The 7.35 kHz signal level during EMP
ON is 
−6 ± 2 dB from the signal level
during EMP OFF.
Note 1: 0dBs = 0.775Vrms
Note 2 :NTSC model: DCR-HC52/HC54
PAL model: DCR-HC51E/HC52E/HC53E/HC54E
Checking Method:
1) Check that the playback signal level is the specified value.
2.
Overall Level Characteristics Check
Mode
Recording (CAMERA mode) and
playback (PLAY/EDIT mode)
Signal
400 Hz, 
−7.5 dBs signal:
Audio left and right terminal of A/V R
jack
Measurement Point
Audio left or right terminal of A/V R
jack
Measuring Instrument
Audio level meter
Specified Value
–7.5 
± 3.0 dBs
Note : 0dBs = 0.775Vrms
Checking Method:
1) Select page: 7, address: 05, and set the bit value of bit 7 to  “1”.
2) Input the 400 Hz, –7.5 dBs signal in the audio left and right
terminal of A/V R jack.
3) Record the signal.
4) Remove the input signal.
5) Playback the recorded section.
6) Check that the 400 Hz signal level is the specified value.
7) Select page: 7, address: 05, and set the bit value of bit 7 to  “0”.
6-46
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
5.
Overall Separation Check
Mode
Recording (CAMERA mode) and
playback (PLAY/EDIT mode)
Signal
400 Hz, 
−7.5 dBs signal:
Audio <left> [right] terminal of A/V
R jack
No signal:
Audio  <left> [right] terminal of A/V
R jack
Measurement Point
Audio <left> [right] terminal of A/V
R jack
Measuring Instrument
Audio level meter
Specified Value
Below 
−40 dBs
Note : 0dBs = 0.775Vrms
< > : Left channel check
[   ] : Right channel check
Checking Method:
1) Select page: 7, address: 05, and set the bit value of bit 7 to  “1”.
2) Input the 400 Hz, 
−7.5 dBs signal in the audio <left> [right]
terminal of A/V R jack.
Connect the audio <left> [right] terminal of A/V R jack to
GND using a jumper wire.
3) Record the signal.
4) Remove the input signal, and remove the jumper wire.
5) Playback the recorded section.
6) Check that the signal level of the audio <left> [right] terminal
is the specified value.
7) Select page: 7, address: 05, and set the bit value of bit 7 to  “0”.
3.
Overall Distortion Check
Mode
Recording (CAMERA mode) and
playback (PLAY/EDIT mode)
Signal
400 Hz, –7.5 dBs signal:
Audio left and right terminal of A/V R
jack
Measurement Point
Audio left or right terminal of A/V
R jack
Measuring Instrument
Audio distortion meter
Specified Value
Below 0.4%
(200 Hz to 6 kHz BPF ON)
Note : 0dBs = 0.775Vrms
Checking Method:
1) Select page: 7, address: 05, and set the bit value of bit 7 to  “1”.
2) Input the 400 Hz, –7.5 dBs signal in the audio left and right
terminal of A/V R jack.
3) Record the signal.
4) Remove the input signal.
5) Playback the recorded section.
6) Check that the distortion is the specified value.
7) Select page: 7, address: 05, and set the bit value of bit 7 to  “0”.
4.
Overall Noise Level Check
Mode
Recording (CAMERA mode) and
playback (PLAY/EDIT mode)
Signal
No signal:
Audio left and right terminal of A/V R
jack
Measurement Point
Audio left or right terminal of A/V
R jack
Measuring Instrument
Audio level meter
Specified Value
Below 
−45 dBs
(IHF-A filter ON, 20 kHz LPF ON)
Note : 0dBs = 0.775Vrms
Checking Method:
1) Select page: 7, address: 05, and set the bit value of bit 7 to  “1”.
2) Connect the audio left terminal of A/V R jack to GND using a
jumper wire.
Connect the audio right terminal of A/V R jack to GND using
a jumper wire.
3) Record the signal.
4) Remove the jumper wires.
5) Playback the recorded section.
6) Check that the noise level is the specified value.
7) Select page: 7, address: 05, and set the bit value of bit 7 to  “0”.
6-47
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
6-4. SERVICE  MODE
4-1.
ADJUSTMENT  REMOTE  COMMANDER
(RM-95)
The adjustment remote commander (RM-95) is used for changing
the calculation coefficient in signal processing, EVR data, etc. The
adjustment remote commander (RM-95) performs bi-directional
communication with the unit using the remote commander signal
line (LANC). The resultant data of this bi-directional communica-
tion is written in the non-volatile memory.
1.
Using the Adjustment Remote Commander (RM-95)
1) Connect the adjustment remote commander to the LANC ter-
minal.
2) Set the HOLD switch of the adjustment remote commander
(RM-95) to “HOLD” (SERVICE position). If it has been prop-
erly connected, the LCD on the adjustment remote commander
(RM-95) will display as shown in Fig. 6-4-1.
Fig. 6-4-1
3) Operate the adjustment remote commander (RM-95) as fol-
lows.
• Changing the page
The page increases when the EDIT SEARCH+ button is
pressed, and decreases when the EDIT SEARCH- button is
pressed. There are altogether 16 pages, from 0 to F.
• Changing the address
The address increases when the FF (M) button is pressed,
and decreases when the REW (m) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (N) button is pressed,
and decreases when the STOP (x) button is pressed. There
are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data in the nonvolatile memory. (The new adjusting data will
not be recorded in the nonvolatile memory if this step is not
performed)
4) After completing all adjustments, turn off the main power sup-
ply (8.4 V) once.
Page
Data
Address
2.
Precautions Upon Using the Adjustment Remote
Commander (RM-95)
Mishandling of the adjustment remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjust-
ments and new adjustment data after each adjustment.
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 1112 13 14 15
Page of 62
Display

Click on the first or last page to see other DCR-HC51E / DCR-HC52 / DCR-HC52E / DCR-HC53E / DCR-HC54 / DCR-HC54E (serv.man4) service manuals if exist.