6-20
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
4-2. Flange Back Adjustment (2) 
RadarW
RadarW
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjustment remote Commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
44 to 54, 56 and 57
Specified value
Data of page: 6, address: 0C is “00”
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) POWER ......................................................... CAMERA mode
2) NIGHTSHOT PLUS ........................................................ OFF
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 2)
3
6
01
13
Press PAUSE (Write) button.
4
Place ND filter on the lens so
that the optimum image is
obtain.
5
6
01
29
Press PAUSE (Write) button.
(Note 3)
6
6
02
Check the data changes to
“01”.
7
6
0C
Check the data is “00”.
Note 2: If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Note 3: The adjustment data will be automatically input to page:
F, address: 44 to 54, 56 and 57.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE (Write) button.
5
0
01
00
6
Perform “Flange Back
Check”.
5.
Flange Back Check
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) POWER ......................................................... CAMERA mode
2) NIGHTSHOT PLUS ........................................................ OFF
Note 2: When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 2.0 m
from the front of the lens.
2
To  open the IRIS, decrease
the luminous intensity to the
Siemens star up to a point be-
fore noise appear on the image.
3
Shoot the Siemens star with
the zoom TELE end.
4
6
40
01
5
6
41
01
6
Turn on the auto focus.
7
0
03
0F
8
1
Check that the lens is
focused. (Note 2)
9
6
21
10
10
Shoot the Siemens star with
the zoom WIDE end.
11
Observe the TV monitor and
check that the lens is
focused.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
0
03
00
6-21
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
Area Deviation
Correction Data
Phase
NTSC
PAL
 Address: 5B Address: 5C Address: 5B Address: 5C
1
22.5˚ to 67.5˚
E8
1A
E4
1A
2
67.5˚ to 112.5˚
00
24
00
24
3
112.5˚ to 157.5˚
18
1A
1C
1A
4
157.5˚ to 202.5˚
20
00
28
00
5
202.5˚ to 247.5˚
18
E6
1C
E6
6
247.5˚ to 292.5˚
00
DC
00
DC
7
292.5˚ to 337.5˚
E8
E6
E4
E6
8
337.5˚ to 22.5˚
E0
00
D8
00
Processing after completion of adjustment:
1) Select page: 6, address: 48, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
Fig. 6-1-11
6. Optical Axis Adjustment
Correct a deviation of optical axis between the lens and the CCD
imager.
If deviated, the screen center will be shifted when the lens is
zoomed from TELE end to WIDE end.
Subject
Clear chart
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
5B, 5C
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: “Flange Back Adjustment” must be already finished.
Note 3: NTSC model: DCR-HC52/HC54
PAL model: DCR-HC51E/HC52E/HC53E/HC54E
Switch setting:
1) POWER ......................................................... CAMERA mode
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADYSHOT (Menu setting) ...................................... OFF
Preparation for adjustment:
1) Play a monoscope portion of the System Check tape (XH5-5
(NTSC) or XH5-5P (PAL)).
2) Stick the optical axis deviation specification frame to the moni-
tor screen so that the center of monoscope coincides with the
center of specification frame.
3) Select the CAMERA mode.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 48, and set data: 01.
3) Select page: F, addresses: 5B and 5C, and set data: 00, and
then press the PAUSE (Write) button on the adjusting remote
commander.
4) Place the Clear Chart attached with a dot of diameter 9.0 
± 1.5
mm at 2 m position away from the lens.
5) Shoot the dot with the zoom at TELE end.
6) Change the lens direction so that the center of dot coincides
with the center of optical axis deviation specification frame.
7) Shoot the dot with the zoom at WIDE end.
8) Check on the monitor TV which area of optical axis deviation
specification frame the dot exists in. (Detect the deviation di-
rection from the center of screen.)
9) Select page: F, addresses: 5B and 5C, and write data corre-
sponding to the detected deviation direction as mentioned be-
low.
• If the deviation amount falls within a circle of which diameter
is 5.5% of the vertical view angle, the deviation amount is as-
sumed to be less, and write data: 00.
0
180
90
67.5
22.5
337.5
292.5
247.5
202.5
157.5
112.5
8
4
5
7
1
6
2
3
270
Circle of vertical 
view angle ratio 
5.5% (diameter)
Circle of vertical 
view angle ratio 
11% (diameter)
Area Deviation
Correction Data
Phase
NTSC
PAL
 Address: 5B Address: 5C Address: 5B Address: 5C
1
22.5˚ to 67.5˚
F4
0E
F2
0E
2
67.5˚ to 112.5˚
00
12
00
12
3
112.5˚ to 157.5˚
0C
0E
0E
0E
4
157.5˚ to 202.5˚
10
00
14
00
5
202.5˚ to 247.5˚
0C
F2
0E
F2
6
247.5˚ to 292.5˚
00
EE
00
EE
7
292.5˚ to 337.5˚
F4
F2
F2
F2
8
337.5˚ to 22.5˚
F0
00
EC
00
• If the deviation amount exists outside a circle of 5.5% of verti-
cal view angle but within a circle of 11%, enter the following
data.
• If the deviation amount exists outside a circle of which diam-
eter is 11% of the vertical view angle, enter the following data.
6-22
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
How to release the picture frame setting:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
03
00
3
6
01
00
4
6
90
00
5
6
91
00
6
6
92
00
7
6
93
00
Check on the oscilloscope
1.
Horizontal period
Fig. 6-1-12
2.
Vertical period
Fig. 6-1-13
Check on the monitor TV (Underscanned mode)
Fig. 6-1-14
7.
Picture Frame Setting
(Color reproduction adjustment frame)
Subject
Color bar chart
(Color reproduction adjustment
frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope and monitor TV
Specified Value
A = B, C = D, E = F
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Perform “Flange Back Adjustment” before this adjust-
ment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu Setting) ......................................... MANUAL
Setting method:
Order
Procedure
1
Adjust the zoom and the camera direction, and set
the specified position.
2
Mark the position of the picture frame on the monitor
TV, and adjust the picture frame to the this position
in following adjustment using “Color reproduction
adjustment frame”.
How to read the XH, XL, YH and YL data:
Order Page Address Data
Procedure
1
0
03
18
2
1
Read XH data and XL data.
(Note 3)
3
0
03
22
4
1
Read YH data and YL data.
(Note 3)
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
90
XL
2
6
91
XH
3
6
92
YL
4
6
93
YH
5
6
01
79
Press PAUSE (Write) button.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
6-23
DCR-HC51E/HC52/HC52E/HC53E/HC54/HC54E_ADJ
8.
F No. Standard Data Input 
RadarW
RadarW
RadarW
Adjust the dispersion of the lens iris every F mumber, and com-
pensate the exposure.
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Adjustment Page
F
Subject
Clear chart (Center frame)
(1 m (PTB-450) or 40 cm (PTB-1450) 
   from of lens)
(Refer to 13. Picture Frame Setting (Center frame)
Adjustment Address
1C to 23
Processing after completing adjustment:
Order
Page
Address
Data
Procedure
1
0
01
01
D8
2
6
02
Check the data is "00"
Order
Page
Address
Data
Procedure
1
6
01
00
00
2
0
01
5
6
02
Check the data is "01"
6
6
0C
Check the data is "00"
3
6
D1
Press PAUSE (write ) button
Press PAUSE (write ) button
BB
4
6
01
Press PAUSE (write ) button
Page of 62
Display

Click on the first or last page to see other DCR-HC51E / DCR-HC52 / DCR-HC52E / DCR-HC53E / DCR-HC54 / DCR-HC54E (serv.man4) service manuals if exist.