DOWNLOAD Sony DCR-HC44E / DCR-HC46 / DCR-HC46E (serv.man3) Service Manual ↓ Size: 809.75 KB | Pages: 73 in PDF or view online for FREE

Model
DCR-HC44E DCR-HC46 DCR-HC46E (serv.man3)
Pages
73
Size
809.75 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc44e-dcr-hc46-dcr-hc46e-sm3.pdf
Date

Sony DCR-HC44E / DCR-HC46 / DCR-HC46E (serv.man3) Service Manual ▷ View online

6-27
DCR-HC44E/HC46/HC46E_ADJ
How to release the picture frame setting:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-11
2. Vertical period
Fig. 6-1-12
Check on the monitor TV (Underscanned mode)
Fig. 6-1-13
7.
Picture Frame Setting
(Color reproduction adjustment frame)
Subject
Color bar chart
(Color reproduction adjustment
frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope and monitor TV
Specified Value
A=B, C=D, E=F
Note 1: Perform “Hall Adjustment” and “Flange Back Adjust-
ment” before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu Setting) ......................................... MANUAL
Setting method:
Order
Procedure
1
Adjust the zoom and the camera direction, and set
the specified position.
2
Mark the position of the picture frame on the monitor
TV, and adjust the picture frame to the this position
in following adjustment using “Color reproduction
adjustment frame”.
How to read the XH, XL, YH and YL data:
Order Page Address Data
Procedure
1
0
03
18
2
1
Read XH data and XL data.
(Note 3)
3
0
03
22
4
1
Read YH data and YL data.
(Note 3)
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
90
XL
2
6
91
XH
3
6
92
YL
4
6
93
YH
5
6
01
79
Press PAUSE (Write) button.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
6-28
DCR-HC44E/HC46/HC46E_ADJ
8.
Picture Frame Setting (Center frame)
Subject
Clear chart (Center frame)
(1 m (PTB-450) or 40 cm (PTB-
1450)  from the front of lens)
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Monitor TV
Specified Value
A clear chart must be shot in larger
size than nine grids in the center of
frame shown on the screen.
(Fig. 6-1-15)
Note: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) ZOOM .................................................................... WIDE end
5) DIGITAL ZOOM (Menu setting) .................................... OFF
6) STEADY SHOT (Menu setting) ..................................... OFF
7) FOCUS (Menu Setting) ......................................... MANUAL
Setting method:
Order Page Address Data
Procedure
1
Shoot a clear chart in the
center of screen with the
zoom at WIDE end.
2
0
01
01
3
E
EF
91
Press PAUSE (Write) button.
4
Check that a clear chart is
shot in larger size than nine
grids in the center of frame
shown on the screen.
5
E
EF
00
Press PAUSE (Write) button.
6
0
01
00
7
In the following adjustment,
if the “Center frame” is used,
adjust the clear chart to this
position.
A clear chart must be shot in larger size than central nine grids. 
Fig.6-1-14
9.
F No. & ND Light Quality Standard Data Input
RadarW
RadarW
RadarW
Correct the lens iris and dispersion of the ND filter light quantity.
Adjustment Page
F
Adjustment Address
1C to 23
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: F, address: 1C to 23.
Note 2: Press the PAUSE (Write) button of the adjustment re-
mote commander each time to set data.
Address Data
1C
F8
1D
03
1E
09
1F
13
20
F1
21
F8
22
13
23
20
3) Select page: 0, address: 01, and set data: 00.
6-29
DCR-HC44E/HC46/HC46E_ADJ
10. MAX GAIN Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects
in low illuminance will not be produced (dark).
Subject
Clear chart (Center frame)
Adjustment Page
F
Adjustment Address
2C
Note 1: Perform “Flange Back and Zoom Lever Center Adjust-
ment” before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4: NTSC model: DCR-HC46
PAL model: DCR-HC44E/HC46E
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) ZOOM .................................................................... WIDE end
5) DIGITAL ZOOM (Menu setting) .................................... OFF
6) STEADY SHOT (Menu setting) ..................................... OFF
7) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Center Frame”. If not,
perform “8. Picture Frame
Setting (Center Frame)”
2
0
01
01
3
6
D0
Set the following data.
20: NTSC model
20: PAL model
4
6
D1
Set the following data.
80: NTSC model
B0: PAL model
5
6
01
6F
Press PAUSE (Write) button.
(Note 6)
6
6
02
Check the data changes to
“01”.
Note 6: The adjustment data will be automatically input to page:
F, address: 2C.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
11. Mechanical Shutter Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the close time and loss time every F number of the me-
chanical shutter and the high-speed shutter correction value to
correct the luminous exposure.
Adjustment Page
F
Adjustment Address
76 to 8B
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: NTSC model: DCR-HC46
PAL model: DCR-HC44E/HC46E
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: F, address: 76 to 8B.
Note 3: Press the PAUSE (Write) button of the adjustment re-
mote commander each time to set data.
Address
Data
NTSC
PAL
76
49
3D
77
8C
D4
78
39
30
79
DC
E2
7A
32
2B
7B
DE
07
7C
2E
27
7D
29
3B
7E
2A
24
7F
33
2A
80
60
5D
81
73
6C
82
79
71
83
76
6D
84
66
5D
85
1E
1D
86
81
82
87
80
80
88
80
80
89
80
80
8A
80
80
8B
80
7F
3) Select page: 0, address: 01, and set data: 00.
Ver. 1.2  2007.09
6-30
DCR-HC44E/HC46/HC46E_ADJ
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
D0
00
3
0
01
00
4
Perform “Color Reproduc-
tion Check”.
NTSC model
PAL model
Fig. 6-1-15
12. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment
frame)
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
37, 39, 40, 41
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Perform “Hall Adjustment” and “Flange Back Adjust-
ment” before this adjustment.
Note 3: NTSC model: DCR-HC46
PAL model: DCR-HC44E/HC46E
Switch setting:
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADYSHOT (Menu setting) ...................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
perform “7. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”
2
0
01
01
3
6
D0
Set the following data.
7C: NTSC model
82: PAL model
4
6
01
3D
Press PAUSE (Write) button.
5
F
F0
Set the following data, and
press PAUSE (Write) button.
37: NTSC model
B7: PAL model
6
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst lumi-
nance point to the burst
position of color reproduc-
tion frame.
7
F
Change the data and settle
each color luminance point in
each color reproduction
frame. (Note 4)
Note 4: Be sure to press the PAUSE (Write) button of the adjust-
ing remote commander before changing the addresses.
If not, the new data will not be written to the memory.
37
39
40
41
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst
position
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst
position
Page of 73
Display