Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc44e-dcr-hc46-dcr-hc46e-sm3.pdf
Date

Sony DCR-HC44E / DCR-HC46 / DCR-HC46E (serv.man3) Service Manual ▷ View online

6-15
DCR-HC44E/HC46/HC46E_ADJ
5.
18 Page table
Note 1: If reading/writing data on pages 18, set data: 01 to page:
0, address: 10, and then select pages: 8. By this data set-
ting, the pages 18 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to“00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to D7
Fixed data-1 (Initialized data)
D8
Fixed data-2
D9 to DC
Fixed data-1 (Initialized data)
DD
Fixed data-2
DE
Fixed data-1 (Initialized data)
DF
E0
Fixed data-2
E1 to E3
Fixed data-1 (Initialized data)
E4
Fixed data-2
E5 to F1
Fixed data-1 (Initialized data)
F2
Fixed data-2
F3 to F6
Fixed data-1 (Initialized data)
F7
Fixed data-2
F8 to FF
Fixed data-1 (Initialized data)
6.
1C Page table
Note 1: If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to“00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 77
Fixed data-1 (Initialized data)
78
Fixed data-2
79 to B2
Fixed data-1 (Initialized data)
B3
00
00
B4
00
00
B5
00
00
B6
00
00
B7
00
00
B8
80
80
B9
00
00
BA
00
00
BB
00
00
BC
00
00
BD
00
00
SD error rate check (LP)
BE
00
00
BF
00
00
C0
00
00
C1
00
00
C2
00
00
C3
80
80
C4
00
00
C5
00
00
C6
00
00
C7
00
00
C8
00
00
C9 to D4
Fixed data-1 (Initialized data)
D5
Fixed data-2
D6 to FF
Fixed data-1 (Initialized data)
6-16
DCR-HC44E/HC46/HC46E_ADJ
2.
Modification of E, F, 14, 19, 1E, 1F Page Data
If the E, F, 14, 19, 1E, 1F page data has been initialized, change
the data of the “Fixed data-2” address shown in the following table
by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 14, 19, 1E, 1F, set data: 01 to
page: 0, address: 10, and then select pages 4, 9, E, F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification E, F, 14, 19, 1E,
1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
1-2-3.
Initialization of E, F, 14, 19, 1E, 1F Page Data
1.
Initializing of E, F, 14, 19, 1E, 1F Page Data
Note 1: If “Initialization of Pages E, F, 14, 19, 1E, 1F” is ex-
ecuted, all data on pages E, F, 14, 19, 1E, 1F are initial-
ized. (Only an individual page cannot be initialized)
Note 2: If the E, F, 14, 19, 1E, 1F page data has been initialized,
the following adjustments need to be performed again.
1) Modification of E, F, 14, 19, 1E, 1F page data
2) Camera system adjustment (if all areas were initial-
ized)
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
14
Adjustment Address
00 to FF
Adjustment Page
19
Adjustment Address
00 to FF
Adjustment Page
1E
Adjustment Address
00 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
Set the following data, and
press PAUSE button.
3
6
01
2D: NTSC model
2F: PAL model
4
6
03
01
Press PAUSE (Write) button.
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE (Write) button.
7
Perform “Modification of E,
F, 14, 19, 1E, 1F Page Data”
Note 3: NTSC model: DCR-HC46
PAL model: DCR-HC44E/HC46E
6-17
DCR-HC44E/HC46/HC46E_ADJ
4.
F Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
Fixed data-1 (Initialized data)
11
80
80
Flange back and zoom lever center
adj.
12
Fixed data-1 (Initialized data)
13
28
28
Hall adj.
14
70
70
15, 16
Fixed data-1 (Initialized data)
17
19
19
18
28
28
Hall adj.
19
D8
D8
1A, 1B
Fixed data-1 (Initialized data)
1C
00
00
1D
00
00
1E
00
00
1F
00
00
F No. standard data input
20
00
00
21
00
00
22
00
00
23
00
00
24
25
Fixed data-2
26 to 29
Fixed data-1 (Initialized data)
2A
35
35
LV standard data input
2B
00
00
2C
7F
70
MAX GAIN adj.
2D
Fixed data-1 (Initialized data)
2E
25
25
2F
00
00
Auto white balance
30
07
07
standard data input
31
00
00
32
15
15
33
00
00
Auto white balance adj.
34
0C
0C
35
00
00
36
Fixed data-1 (Initialized data)
37
45
48
Color reproduction adj.
38
Fixed data-1 (Initialized data)
39
2C
2E
Color reproduction adj.
3A to 3F
Fixed data-1 (Initialized data)
40
F9
FE
Color reproduction adj.
41
EA
E1
42, 43
Fixed data-1 (Initialized data)
3.
E Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 0B
Fixed data-1 (Initialized data)
0C
Fixed data-2
0D
Fixed data-1 (Initialized data)
0E
Fixed data-2
0F, 10
Fixed data-1 (Initialized data)
11
Fixed data-2
12 to 1F
Fixed data-1 (Initialized data)
20
21
Fixed data-2
22
23 to 45
Fixed data-1 (Initialized data)
46
Fixed data-2
47 to 53
Fixed data-1 (Initialized data)
54
55
Fixed data-2
56 to 5B
Fixed data-1 (Initialized data)
5C
5D
5E
5F
60
Fixed data-2
61
62
63
64 to 71
Fixed data-1 (Initialized data)
72
73
Fixed data-2
74 to 7C
Fixed data-1 (Initialized data)
7D
Fixed data-2
7E to BF
Fixed data-1 (Initialized data)
C0
Fixed data-2
C1 to CB
Fixed data-1 (Initialized data)
CC
Fixed data-2
CD to D5
Fixed data-1 (Initialized data)
D6
Fixed data-2
D7, D8
Fixed data-1 (Initialized data)
D9
Fixed data-2
DA to FF
Fixed data-1 (Initialized data)
6-18
DCR-HC44E/HC46/HC46E_ADJ
F Page table
Address
Initial value
Remark
NTSC PAL
44
29
29
45
38
38
Auto white balance adj.
46
57
57
47
20
20
48
37
37
49
1D
1D
4A
3B
3B
4B
7A
7A
4C
1C
1C
4D
1F
1F
4E
00
00
4F
00
00
Flange back and zoom lever center
50
00
00
adj.
51
00
00
52
75
75
53
19
19
54
00
00
55
4A
4A
56
00
00
57
00
00
58
00
00
MR adj./Flange back and zoom
lever center adj.
59
Fixed data-1 (Initialized data)
5A
80
80
5B
80
80
5C
80
80
5D
80
80
5E
40
40
5F
C0
C0
MR adj.
60
40
40
61
C0
C0
62
40
40
63
C0
C0
64
40
40
65
C0
C0
66 to 71
Fixed data-1 (Initialized data)
72
73
Fixed data-2
74, 75
Fixed data-1 (Initialized data)
76
5C
4D
77
00
00
78
47
3C
79
00
00
7A
3E
34
Mechanical shutter adj.
7B
00
00
7C
38
2F
7D
00
00
Address
Initial value
Remark
NTSC PAL
7E
28
20
7F
00
00
80
62
60
81
7A
75
82
81
7B
83
7C
76
84
6A
63
Mechanical shutter adj.
85
1E
1E
86
80
80
87
80
80
88
80
80
89
80
80
8A
80
80
8B
80
80
8C to AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to B1
Fixed data-1 (Initialized data)
B2
Fixed data-2
B3 to CB
Fixed data-1 (Initialized data)
CC
CD
Fixed data-2
CE, CF
Fixed data-1 (Initialized data)
D0
Fixed data-2
D1, D2
Fixed data-1 (Initialized data)
D3
D4
Fixed data-2
D5 to F7
Fixed data-1 (Initialized data)
F8
Fixed data-2
F9
Fixed data-1 (Initialized data)
FA
FB
Fixed data-2
FC to FF
Fixed data-1 (Initialized data)
Page of 73