DOWNLOAD Sony DCR-HC16E / DCR-HC18E / DCR-HC20 / DCR-HC20E (serv.man4) Service Manual ↓ Size: 868.83 KB | Pages: 59 in PDF or view online for FREE

Model
DCR-HC16E DCR-HC18E DCR-HC20 DCR-HC20E (serv.man4)
Pages
59
Size
868.83 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc16e-dcr-hc18e-dcr-hc20-dcr-hc20e-sm4.pdf
Date

Sony DCR-HC16E / DCR-HC18E / DCR-HC20 / DCR-HC20E (serv.man4) Service Manual ▷ View online

6-35
DCR-HC16E/HC18E/HC20/HC20E
3-1-2.
Precautions on Adjusting
Note1:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
1)
The adjustments of this unit are performed in the VTR mode
(PLAY/EDIT mode) or camera mode (CAMERA mode).
To set to the VTR mode, set the mode switch to “PLAY/EDIT”
or set the “Forced VTR Power ON mode” using the adjusting
remote commander (Note2).
To set to the camera mode, set the mode switch to “CAMERA”
or set the “Forced Camera Power ON mode” using the adjusting
remote commander (Note3).
After completing adjustments, be sure to exit the “Forced VTR
Power ON Mode” or “Forced Camera Power ON Mode”.
(Note4)
2)
The cabinet (R) block need not be connected. To remove it,
disconnect the following connectors.
VC-350 board CN1002 (8P, 0.5mm)
VC-350 board CN1011 (6P, 0.5mm)
VC-350 board CN1006 (22P, 0.5mm)
3)
The front panel block (Microphone unit, IR-051 board) need
not be connected. To remove it, disconnect the following
connector.
IR-051 board CN602 (16P, 0.5mm)
4)
The EVF block and the battery panel section need not be
connected except for the DC IN jack of the battery panel section.
To remove them, disconnect the following connector.
VC-350 board CN9301 (20P, 0.5mm)
The following connector must be connected to connect the DC
IN jack.
VC-350 board CN2001 (26P, 0.5mm)
5)
The lens block (CD-489 board, SE-141 board) need not be
connected. To remove it, disconnect the following connectors.
VC-350 board CN3001 (14P, 0.5mm)
VC-350 board CN3101 (23P, 0.3mm)
SE-141 board CN401 (6P, 0.5mm)
6)
By setting the “Forced VTR Power ON mode”, the VTR section
can be operate even if the control switch block (SS6300) has
been removed. When removing it, disconnect the following
connector.
VC-350 board CN1001 (18P, 0.5mm)
7)
The MS-200 board need not be connected. But removing the
MS-200 board (removing the VC-350 board CN1005) means
removing the lithium 3V power supply (MS-200 board, BT501),
data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data.
But, the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the MS-200 board
has been removed. (Refer to “6-4.Service Mode” for the data
on the history use and the self-diagnosis data.)
To remove the MS-200 board, disconnect the following
connectors.
VC-350 board CN1005 (20P 0.5mm)
Note2:
Setting the “Forced VTR Power ON” mode (PLAY/EDIT mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjusting remote commander.
The above procedure will enable the VTR power to be turned
on with the control switch block (SS6300 block) removed.
After completing adjustments, be sure to exit the “Forced Power
ON mode”.
Note3:
Setting the “Forced Camera Power ON” mode (CAMERA mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjusting remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (SS6300 block) removed.
After completing adjustments, be sure to exit the “Forced Power
ON mode”.
Note4:
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 0, address: 01, and set data: 0
6-36
DCR-HC16E/HC18E/HC20/HC20E
3-1-3.
Adjusting Connectors
The measuring point of the playback RF signal is CN1007 of VC-
350 board. Connect the measuring instruments via the CPC
connecting jigs (J-6082-521-A, J-6082-564-A). Refer to
“MECHANISM SECTION ADJUSTMENT” for the measuring
method. The following table lists the pin numbers and signal names
of CN1007.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
RF MON
SWP
GND
XCS EEP
EEP SCK
EEP SO
EEP SI
GND
Table 6-3-1.
3-1-4.
Connecting the Equipment
Connect the measuring instruments as shown in Fig. 6-3-2, and
perform the adjustments.
Adjustment
remote
commander
LANC jack
Main unit
AUDIO/VIDEO jack
TV monitor
VIDEO
(Yellow)
AUDIO L (White)
AUDIO R (Red)
Fig. 6-3-2.
Fig. 6-3-1.
Remove the CPC lid
8
CN1007
1
6-37
DCR-HC16E/HC18E/HC20/HC20E
3-1-5.
Alignment Tapes
Use the alignment tapes shown in the following table.
Use tapes specified in the signal column of each adjustment.
Fig. 6-3-3 shows the 75% color bar signals recorded on the alignment
tape for Audio Operation Check.
Note:
Measure with video terminal (Terminated at 75 
)
Use
Tape path adjustment
Switching position adjustment
Audio system adjustment
Operation check
Name
Tracking standard (XH2-1)
SW/OL standard (XH2-3)
Audio operation check
(XH5-3 (NTSC), XH5-3P (PAL))
System operation check
(XH5-5 (NTSC), XH5-5P (PAL))
For NTSC model
For PAL model
Color bar signal waveform
Color bar pattern
Color bar signal waveform
Color bar pattern
Fig. 6-3-3. Color bar signal of alignment tapes
3-1-6.
Input/Output Level and Impedance
Video input/output
A/V jack
Video signal:
1 Vp-p, 75 
 unbalanced,
sync negative
S video input/output
A/V jack
Luminance signal:
1 Vp-p, 75 
 unbalanced,
sync negative
Chrominance signal: 0.286 Vp-p, 75 
 unbalanced (NTSC)
: 0.300 Vp-p, 75 
 unbalanced (PAL)
Audio input/output
A/V jack
Input level: 327mV
Input impedance: More than 47k
Output level: 327 mV (at load impedance 47 k
)
Output impedance: Below 2.2 k
1V
0.714V
0.286V
White (75%)
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
0.286V
Q
I
Horizontal sync signal
(75%)
White
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Q
I
White
(100%)
Black
1V
0.7V
0.3V
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
Horizontal sync signal
0.3V
(100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
White
Blac
k
6-38
DCR-HC16E/HC18E/HC20/HC20E
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Initialization of 8, A, C, D, E, F, 1C, 1F Page Data
If the 8, A, C, D, E, F, 1C, 1F page data is erased due to some
reason, perform “1-2. INITIALIZATION OF 8, A, C, D, E, F, 1C,
1F PAGE DATA” of “6-1. CAMERA SECTION ADJUSTMENT”
Note: When reading or writing the 1C, 1F page data, select page: 0,
address: 10, and set data: 01, then select C or F page. The 1C or 1F
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
2. Touch Panel Adjustment
Adjust the calibration of the touch panel.
Mode
PLAY/EDIT (VTR stop)
Signal
Arbitrary
Adjustment Page
A
Adjustment Address
82 to 85
Note1: This adjustment should be carried out upon completion of the LCD
system adjustments.
Note2: Perform this adjustment with observing the screen from the front.
Note3: Check that the LCD panel is not reverse mode.
Note4: The data of page: 0, address: 10 must be “00”.
Adjusting method:
1)
Select page: 7, address: 05, and set data: 01.
2)
Using a stylus, push the center of “X” indicated in the part A.
3)
Using a stylus, push the center of “X” indicated in the part B.
4)
Using a stylus, push the center of “X” indicated in the part C.
5)
Select page: 7, address: 05, and check that the data is “00”.
A
C
B
Fig. 6-3-4.
Page of 59