Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc16e-dcr-hc18e-dcr-hc20-dcr-hc20e-sm4.pdf
Date

Sony DCR-HC16E / DCR-HC18E / DCR-HC20 / DCR-HC20E (serv.man4) Service Manual ▷ View online

6-27
DCR-HC16E/HC18E/HC20/HC20E
13. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video terminal of
Display data
AUDIO/VIDEO
of page 1 (Note3)
jack
Measuring Instrument
Vectorscope
Adjustment
remote commander
Specified Value 1
Fig. 6-1-13. A to B
Specified Value 2
R ratio : 29C0 to 2A40 (NTSC)
2A80 to 2B00 (PAL)
B ratio : 5CC0 to 5D40 (NTSC)
5BC0 to 5C40 (PAL)
Specified Value 3
8000 to 8BC0
Note1:
Perform “Auto White Balance Adjustment” before this adjustment.
If not performed, R ratio data and B ratio data may not satisfy the
specified value 2.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note4:
NTSC model : DCR-HC20
PAL model
: DCR-HC16E/HC18E/HC20E
Switch setting:
1)
MODE .................................................................... CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Checking method:
Order Page Address Data
Procedure
Indoor white balance check
1
Check that the lens is not covered
with either filter.
2
6
48
02
Set the data.
3
6
01
0F
Set the data, and press PAUSE
button.
4
Check that the center of the white
luminance point is within the
circle shown Fig. 6-1-13. A.
5
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
6
Place the C14 filter on the lens.
7
6
01
3F
Set the data, and press PAUSE
button.
8
Check that the center of the white
luminance point is within the
circle shown Fig. 6-1-13. B.
9
0
03
04
Set the data.
10
1
Check that the display data
(Note3) satisfies the R ratio
specified value.
11
0
03
05
Set the data.
12
1
Check that the display data
(Note3) satisfies the B ratio
specified value.
13
Remove the C14 filter.
LV data check
14
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
15
6
01
00
Set the data, and press PAUSE
button.
16
0
03
06
Set the data.
17
1
Check that the display data
(Note3) satisfies the specified
value 3.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
Remove the ND filter.
R-Y
2mm
B-Y
2mm
R-Y
B-Y 
0.5mm
1mm
3mm
3mm
Fig. 6-1-13 (A).
Fig. 6-1-13 (B).
6-28
DCR-HC16E/HC18E/HC20/HC20E
14. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A : ENC03MA
Type B : ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2680 to 5080
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (CAMERA SET menu) ......................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(SE-141 board SE401)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
Yaw sensor check
(SE-141 board SE402)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
5
0
03
00
Set the data.
6
Move the camcorder, and check
that the steady shot operations
have been performed normally
Note3:
Don’t move the camcorder.
6-29
DCR-HC16E/HC18E/HC20/HC20E
1-4.
ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
As the PANEL OPEN switch is attached to the cabinet (R), this
cabinet must be attached when performing adjustments.
If you perform the adjustments with cabinet (R) removed, set the
following data.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
Note4:
NTSC model : DCR-HC20
PAL model
: DCR-HC16E/HC18E/HC20E
Switch setting:
LCD panel ........................................................................... Closed
1. EVF Automatic Adjustment (VC-350 board)
This adjustment does the following adjustment items automatically.
VCO adjustment
Contrast adjustment
Mode
CAMERA
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
3F, 40 (VCO adj.)
47 (Contrast adj.)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
71
00
Set the data, and press PAUSE
button.
3
3
01
5A
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note2)
6
C
3F
Read the data, and this data is
named D
3F
.
7
Convert D
3F
 to decimal notation,
and obtain D
3F
’. (Note3)
8
Calculate D
40
’ using following
equations (Decimal calculation)
[NTSC model]
When D
3F
’   245
D
40
’ = D
3F
’+10
When D
3F
’ > 245
D
40
’ = 255
[PAL model]
When D
3F
’   10
D
40
’ = D
3F
’– 10
When D
3F
’ < 10
D
40
’ = 0
9
Convert D
40
’ to a hexadecimal
number, and obtain D
40
. (Note3)
10
C
40
D
40
Set the data, and press PAUSE
button.
11
C
71
41
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Note2:
If the data is “01”, adjustment has errors. Contents of the error is
written into page: 3, addresses: C6. See the following table.
Note3:
Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Data of page: 3,
address: C6
5E
61
Contents of error
VCO adjustment error
Contrast adjustment error
6-30
DCR-HC16E/HC18E/HC20/HC20E
1-5.
LCD SYSTEM ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
NTSC model : DCR-HC20
PAL model
: DCR-HC16E/HC18E/HC20E
Switch setting:
LCD panel ............................................................................. Open
1. LCD Automatic Adjustment (PD-213 board)
This adjustment does the following adjustment items automatically.
VCO adjustment
Contrast adjustment
Mode
CAMERA
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
50, 51 (VCO adj.)
58 (Contrast adj.)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
70
00
Set the data, and press PAUSE
button.
3
3
01
5A
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note2)
6
C
50
Read the data, and this data is
named D
50
.
7
Convert D
50
 to decimal notation,
and obtain D
50
’. (Note3)
8
Calculate D
51
’ using following
equations (Decimal calculation)
[NTSC model]
When D
50
’   245
D
51
’ = D
50
’ + 10
When D
50
’ > 245
D
51
’ = 255
[PAL model]
When D
50
’   10
D
51
’ = D
50
’ – 10
When D
50
’ < 10
D
51
’ = 0
9
Convert D
51
’ to a hexadecimal
number, and obtain D
51
. (Note3)
10
C
51
D
51
Set the data, and press PAUSE
button.
11
C
70
41
Set the data, and press PAUSE
button.
12
0
01
00
Set the data.
Note2:
If the data is “01”, adjustment has errors. Contents of the error is
written into page: 3, addresses: C6. See the following table.
Data of page: 3,
address: C6
58
60
Contents of error
VCO adjustment error
Contrast adjustment error
Note3:
Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Page of 59
Display

Click on the first or last page to see other DCR-HC16E / DCR-HC18E / DCR-HC20 / DCR-HC20E (serv.man4) service manuals if exist.