DOWNLOAD Sony DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) Service Manual ↓ Size: 1.27 MB | Pages: 62 in PDF or view online for FREE

Model
DCR-HC14E DCR-HC15 DCR-HC15E (serv.man4)
Pages
62
Size
1.27 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc14e-dcr-hc15-dcr-hc15e-sm4.pdf
Date

Sony DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) Service Manual ▷ View online

6-27
DCR-HC14E/HC15/HC15E
14. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03MA
Type B: ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2B00 to 4B00
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (Menu setting) ....................................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(MA-421 board SE5402)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
Yaw sensor check
(MA-421 board SE5401)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
5
0
03
00
Set the data.
6
Move the camcorder, and check
that the steady shot operations
have been performed normally
Note3:
Don’t move the camcoder.
6-28
DCR-HC14E/HC15/HC15E
1-4.
ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
As the PANEL CLOSE switch is attached to the cabinet (R), this
cabinet must be attached when performing adjustments.
If you perform the adjustments with cabinet (R) removed, set the
following data.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
Note4:
NTSC model : DCR-HC15
PAL model
: DCR-HC14E/HC15E
Switch setting
LCD panel .................................................................... Closed
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN1004 of VC-311 board.
Connect the Measuring Instruments via the CPC-7 jig (J-6082-382-
A).
The following table shows the Pin No. and signal name of CN1004.
Table 6-1-10.
1. VCO Adjustment (VA-118 board)
Set the VCO free-run frequency. If deviated, the EVF screen will
be blurred.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qa of CN1004 of VC-311 board
(EVF VCO)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
36, 37
Specified Value
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
36
Change the data and set the VCO
frequency (f) to the specified
value.
3
C
36
Press PAUSE button.
4
C
36
Read the data, and this data is
named D
36
.
5
Convert D
36
 to decimal notation,
and obtain D
36
’. (Note2)
6
Calculate D
37
’ using following
equations (Decimal calculation)
[NTSC model]
When D
36
’   231
D
37
’ = D
36
’+24
When D
36
’ > 231
D
37
’ = 255
[PAL model]
When D
36
’   24
D
37
’ = D
36
’–24
When D
36
’ < 24
D
37
’ = 0
7
Convert D
37
’ to a hexadecimal
number, and obtain D
37
. (Note2)
8
C
37
D
37
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2:
Refer to “Table 5-4-1. Hexadecimal-decimal Conversion Table”.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
FRRV
RF MON
RF IN/LANC
JACK IN
SWP
PANEL COM
REG_GND
H START
REG_GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
PANEL VG
REG_GND
EVF VCO
REG_GND
EVF VG
EXT DA
LANC SIG
N.C.
Fig. 6-1-15.
CN1004
Remove the CPC lid
16
1
6-29
DCR-HC14E/HC15/HC15E
2. RGB AMP Adjustment (VA-118 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Note:
Do either of the automatic adjustment or the manual adjustment.
2-1. Automatic Adjustment
Mode
Camera
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
39
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
50
Set the data, and press PAUSE
button.
3
3
02
Check that the data changes from
“50” to “00”.
4
3
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
2-2. Manual Adjustment
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qd of CN1004 of VC-311 board
(EVF VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
39
Specified Value
A = 7.50 ± 0.10V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
39
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to the
specified value.
3
C
39
Press PAUSE button.
4
0
01
00
Set the data.
Pedestal
Pedestal
A
2H
Fig. 6-1-16.
6-30
DCR-HC14E/HC15/HC15E
3. Contrast Adjustment (VA-118 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Note:
Do either of the automatic adjustment or the manual adjustment.
3-1. Automatic Adjustment
Mode
Camera
Subject
Arbitrary
Adjustment Page
C
Adjustment Address
3E
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
51
Set the data, and press PAUSE
button.
3
3
02
Check that the data changes from
“51” to “00”.
4
3
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
3-2. Manual Adjustment
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin qd of CN1004 of VC-311 board
(EVF VG)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
3E
Specified Value
A = 2.50 ± 0.10V
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
3E
Change the data and set the
voltage (A) between the 100 IRE
and 0 IRE (pedestal) to the
specified value. (The data should
be “00” to “7F”.)
3
C
3E
Press PAUSE button.
4
0
01
00
Set the data.
100 IRE
Pedestal
A
2H
Fig. 6-1-17.
Page of 62
Display

Click on the first or last page to see other DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) service manuals if exist.