6-15
DCR-HC14E/HC15/HC15E
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F
Page Data”.)
Table. 6-1-8.
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26 to 29
2A
2B
26 to 29
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
80
81
5D
8B
9A
80
7A
1B
00
07
00
0E
00
0D
00
22
27
00
F1
2B
C0
5A
00
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
80
81
5D
8B
9A
80
7A
1B
00
07
00
0E
00
0D
00
22
24
00
EF
2C
40
59
30
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
36MHz origin osc. adj.
Fixed data-1
Fixed data-2
HALL adj.
Fixed data-1
MAX GAIN adj.
LV standard data input
AWB standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Auto white balance adj.
Flange back adj.
Address
Remark
Initial value
Initial value
NTSC PAL
43 to 45
46
47 to 55
56
57
58
59 to 5B
5C
5D
5E to 6B
6C
6D to 6F
70
71 to 74
75
76 to 86
87
88 to 8B
8C
8D
8E to BC
BD
BE to C8
C9
CA
CB
CC to E4
E5
E6 to FF
FF
Fixed data-1
Optical axis adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
FF
6-16
DCR-HC14E/HC15/HC15E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “36MHz
Origin Oscillation Adjustment”), check that the specified values of
“VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 36MHz Origin Oscillation Adjustment
(VC-311 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin eg of IC2501
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f=13500000 ± 68Hz
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
When open the VA-118 board, use the following extension cable
between the VC-311 board CN1002 and VA-118 board CN4004.
J-6082-352-A (100P, 0.5mm)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13, 14, 15
Specified Value 1
88 to 8C
Specified Value 2
15 to 19
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
IRIS display data
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
POWER ................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
8A
Set the data.
3
6
95
17
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note4)
6
6
01
00
Set the data, and press PAUSE
button.
Note4:
The adjustment data will be automatically input to page: F, address:
13, 14, 15.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
Fig. 6-1-7.
IC2501
61
60
80
1
20
21
40
41
VC-311 BOARD(SIDE A)
6-17
DCR-HC14E/HC15/HC15E
3. Flange Back Adjustment (Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
32 to 42
Note1:
Dark Siemens star chart.
Note2:
This adjustment should be carried out upon completion of “HALL
Adjustment”.
Note3:
Make the lens horizontal and perform this adjustment.
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
POWER ................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note:
The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage:
The specified voltage varies according to the minipattern box, so
adjust the power supply output voltage to the specified voltage
written on the sheet which is supplied with the minipattern box.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button.
4
6
01
27
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note6)
Note6:
The adjustment data will be automatically input to page: F, address:
32 to 42.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”.
Fig. 6-1-8.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
6-18
DCR-HC14E/HC15/HC15E
4. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
4-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass)
(Luminance: 350 ± 50 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
32 to 42
Note1:
This adjustment should be carried out upon completion of “HALL
Adjustment”.
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
POWER ................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Preparations:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button.
4
6
01
15
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note5)
Note5:
The adjustment data will be automatically input to page: F, address:
32 to 42.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
Turn off the power and turn on
again.
2
Perform “Flange Back
Adjustment (2)”
4-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
32 to 42
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
POWER ................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button.
4
Place a ND filter on the lens so
that the optimum image is obtain.
5
6
01
29
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
32 to 42.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”