DOWNLOAD Sony DCR-HC1000 / DCR-HC1000E (serv.man4) Service Manual ↓ Size: 1020.41 KB | Pages: 70 in PDF or view online for FREE

Model
DCR-HC1000 DCR-HC1000E (serv.man4)
Pages
70
Size
1020.41 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc1000-dcr-hc1000e-sm4.pdf
Date

Sony DCR-HC1000 / DCR-HC1000E (serv.man4) Service Manual ▷ View online

6-62
DCR-HC1000/HC1000E
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
B
Example:
If “8E” is displayed on the adjustment remote commander, the
bit values for bit7 to bit4 are shown in the A column, and the
bit values for bit3 to bit0 are shown in the B column.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
3. Bit value discrimination
Bit values must be discriminated using the display data of the
adjustment remote commander for following items. Use the table
below to discriminate if the bit value is “1” or “0”.
A
4. Switch check (1)
Page 2
Address 81
Note:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 2, address: 81.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
5. Switch check (2)
Page 7
Address F3
Note:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: F3.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
Bit
0
1
3
4
5
Function
POWER SW (XPOWER SW) (PS8200 block S5)
POWER SW (XMODE SW) (PS8200 block S5)
EJECT SW (XEJECT SW) (PS8200 block S4)
CC DOWN SW (Mechanism chassis)
DISPLAY/BATTERY INFO SW (XBATT INFO SW)
(FP-958 flexible S6002)
When bit value=1
ON
ON
ON
ON (DOWN)
ON
When bit value=0
OFF
OFF
OFF
OFF (UP)
OFF
Bit
0
Function
AUDIO VIDEO jack (JK-271 board CN5401)
When bit value=1
Used
When bit value=0
Not used
6. Switch check (3)
Page 7
Address F4
Note:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: F4.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
Bit
2
3
Function
FRONT MIC jack (FP-954 flexible J001)
FRONT MIC jack (FP-954 flexible J001)
When bit value=1
Used
Monaural MIC is
used
When bit value=0
Not used
Stereo MIC is used/
Not used
6-63
DCR-HC1000/HC1000E
Data (4 digits)
7. Switch check (4)
Page 7
Address F9
Note:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: F9.
2)
By discriminating the bit value of display data, the state of the switch can be discriminated.
Bit
5
6
Function
REAR MIC jack (FP-954 flexible J002)
REAR MIC jack (FP-954 flexible J002)
When bit value=1
Used
Monaural MIC is
used
When bit value=0
Not used
Stereo MIC is used/
Not used
8. Switch check (5)
Page 7
Address 60 to 6B
Note:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 60 to 6B.
2)
By discriminating the display data, the pressed key can be discriminated.
Example: If the data of address: 60 is “00” and the data of address: 61 is “02”, the data of KEY AD0 signal is “0002”. It can be
discriminated that the START/STOP button is pressed.
Address
60 (Upper digits)
61 (Lower digits)
(KEY AD0)
(IC8401 <zc.>)
62 (Upper digits)
63 (Lower digits)
(KEY AD1)
(IC8401 <zv/>>)
64 (Upper digits)
65 (Lower digits)
(KEY AD2)
(IC8401 <zvz>>)
66 (Upper digits)
67 (Lower digits)
(KEY AD3)
(IC8401 <zvx>>)
68 (Upper digits)
69 (Lower digits)
(KEY AD4)
(IC8401 <zvc>)
6A (Upper digits)
6B (Lower digits)
(KEY AD5)
(IC8401 <zvv>)
0000
(0000 to 0035)
START/STOP
(PS8200 block)
(S3)
BACK LIGHT
(FP-958 flexible)
(S6001)
REC START/STOP
(SS8200 block)
(S001)
FLASH
(FP-953 flexible)
(S1001)
PANEL CLOSE
(FP-958 flexible)
(S6003)
PHOTO
(PHOTO REC)
(PS8200 block)
(S2)
006C
(0036 to 00A2)
FOCUS/ZOOM
ZOOM
(FP-958 flexible)
(S6004)
LCD BACK LIGHT
(SS8200 block)
(S002)
PANEL REVERSE
(FP-955 flexible)
(S3001)
PHOTO
(PHOTO FREEZE)
(PS8200 block)
(S1)
00D8
(00A3 to 0113)
FOCUS/ZOOM
FOCUS MANUAL
(FP-958 flexible)
(S6004)
AUTO LOCK
ON
(FP-958 flexible)
(S6005)
03FC
(03A0 to 03FF)
No key input
FOCUS/ZOOM
FOCUS AUTO
(FP-958 flexible)
(S6004)
AUTO LOCK
OFF
(FP-958 flexible)
(S6005)
PANEL NORMAL
(FP-955 flexible)
(S3001)
PANEL OPEN
(FP-958 flexible)
(S6003)
No key input
6-64
DCR-HC1000/HC1000E
9. LED check
Page 7
Address 00, 01, 04
Note:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
Select page: 7, address: 01, and set data: 90.
2)
Select page: 7, address: 04, and set data: 01.
3)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
4)
Check that the following LEDs are lit.
TALLY, CHARGE, CAMERA-TAPE, CAMERA-MEMORY, PLAY/EDIT, MEMORY STICK
5)
Select page: 7, address: 01, and set data: 90.
6)
Select page: 7, address: 04, and set data: 00.
7)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
8)
Select page: 7, address: 00, and set data: 00.
9)
Select page: 7, address: 01, and set data: 00.
10. Record of Use check (1)
Page 7
Address A7 to A9
Note1:
When replacing the drum assembly or the mechanism deck, initialize the data of address: A7 to A9.
Note2:
This data will be kept even if the lithium battery (FP-953 flexible board BT1001) is removed.
Note3:
The data of page: 0, address: 10 must be “00”.
Address
A7
A8
A9
Function
Drum rotation
Hour (H)
counted time
Hour (M)
(BCD code)
Hour (L)
Remarks
100000th place digit and 10000th place digit of counted time
1000th place digit and 100th place digit of counted time
10th place digit and 1st place digit of counted time
Using method:
1)
The record of use data is displayed at addresses: A7 to A9.
Initializing method:
1)
Select page: 7, address: A7, set data: 00 and press the PAUSE button.
2)
Select page: 7, address: A8, set data: 00 and press the PAUSE button.
3)
Select page: 7, address: A9, set data: 00 and press the PAUSE button.
11. Record of Use check (2)
Page 7
Address C8 to CD
Note1:
This data will be kept even if the lithium battery (FP-953 flexible board BT1001) is removed.
Note2:
The data of page: 0, address: 10 must be “00”.
Using method:
1)
The record of use data is displayed at addresses: C8 to CD.
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence data
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
6-65
DCR-HC1000/HC1000E
12. Record of Self-diagnosis check
Page 7
Address B0 to C6
Note1:
This data will be kept even if the lithium battery (FP-953 flexible
board BT1001) is removed.
Note2:
The data of page: 0, address: 10 must be “00”.
Address
Self-diagnosis code
B0
“Repaired by” code (Occurred 1st time)   *1
B1
“Block function” code (Occurred 1st time)
B2
“Detailed” code (Occurred 1st time)
B4
“Repaired by” code (Occurred 2nd time)   *1
B5
“Block function” code (Occurred 2nd time)
B6
“Detailed” code (Occurred 2nd time)
B8
“Repaired by” code (Occurred 3rd time)   *1
B9
“Block function” code (Occurred 3rd time)
BA
“Detailed” code (Occurred 3rd time)
BC
“Repaired by” code (Occurred 4th time)   *1
BD
“Block function” code (Occurred 4th time)
BE
“Detailed” code (Occurred 4th time)
C0
“Repaired by” code (Occurred 5th time)   *1
C1
“Block function” code (Occurred 5th time)
C2
“Detailed” code (Occurred 5th time)
C4
“Repaired by” code (Occurred the last time)   *1
C5
“Block function” code (Occurred the last time)
C6
“Detailed” code (Occurred the last time)
*1:
“01” 
t “C”, “03” t “E”
Using method:
1)
The past self-diagnosis codes are displayed at addresses: B0 to C6. Refer to “SELF-DIAGNOSIS CODE TABLE” for detail of the self-
diagnosis code.
Initializing method:
1)
Select page: 7, address: 01, and set data: C0.
2)
Select page: 7, address: 00, set data: 01 and press the PAUSE button.
3)
Check that the data of page: 7, address: B0 to C7 are “00”.
4)
Select page: 7, address: 00, and set data: 00.
5)
Select page: 7, address: 01, and set data: 00.
Note3:
When the flash error code (E:91:**) is displayed. After repair, clear the error flag in the following method.
1) Select page: 7, address: 01, and set data: 75.
2) Select page: 7, address: 00, set data: 01 and press the PAUSE button.
3) Check that the data of page: 7, address: 02 is “01”.
Page of 70
Display