Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd202e-dcr-dvd203-dcr-dvd203e-dcr-dvd703-dcr-.pdf
Date

Sony DCR-DVD202E / DCR-DVD203 / DCR-DVD203E / DCR-DVD703 / DCR-DVD703E (serv.man4) Service Manual ▷ View online

6-17
DCR-DVD202E/DVD203/DVD203E/DVD703/DVD703E
7.
1E Page table
Note 1:
If reading/writing data on pages 1E, set data: 01 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 1E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00
Fixed data-2
01 to 03
Fixed data-1 (Initialized data)
04
Fixed data-2
05, 06
Fixed data-1 (Initialized data)
07
08
Fixed data-2
09 to 17
Fixed data-1 (Initialized data)
18
19
1A
1B
1C
Fixed data-2
1D
1E
1F
20 to AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to D1
Fixed data-1 (Initialized data)
D2
D3
D4
Fixed data-2
D5
D6 to D8
Fixed data-1 (Initialized data)
D9
DA
DB
Fixed data-2
DC
DD to FF
Fixed data-1 (Initialized data)
8.
1F Page table
Note 1:
If reading/writing data on pages 1F, set data: 01 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (“Refer to 1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (“Refer to 2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 1A
Fixed data-1 (Initialized data)
1B
Fixed data-2
1C to AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to AF
Fixed data-1 (Initialized data)
B0
B1
Fixed data-2
B2 to B9
Fixed data-1 (Initialized data)
BA
Fixed data-2
BB
Fixed data-1 (Initialized data)
BC
Fixed data-2
BD to E6
Fixed data-1 (Initialized data)
E7
Fixed data-2
E8 to FF
Fixed data-1 (Initialized data)
6-18
DCR-DVD202E/DVD203/DVD203E/DVD703/DVD703E
1-2-3.
Initialization of C, 1C Page Data
1.
Initializing of C, 1C Page Data
Note1:
If “Initialization of Pages C, 1C” is executed, all data on
pages C, 1C are initialized. (Only an individual page can-
not be initialized)
Note2 :
If the C, 1C page data has been initialized, the following
adjustments need to be performed again.
1) Modification of C, 1C page data
2) Input of board type data
3) LCD/EVF system adjustments
4) Video system adjustments
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
1C
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
80
0F
Press PAUSE button.
Check the data changes to
4
3
80
“1F”.
Perform “Modification of C,
5
1C Page Data”
Note 3:
If other than adjustment address was initialized, the ad-
justed data is not initialized.
2.
Modification of C, 1C Page Data
If the C, 1C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages C, set data: 00 to page: 0,
address: 10, and then select pages C.
3) If modification of data on pages 1C, set data: 01 to page: 0,
address: 10, and then select pages C.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) Check that the data at the addresses for adjustment are initial
values (adjustment initial values) listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification C, 1C page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
Note 2:
This operation should be done with the adjustment re-
mote commander. The operation of page: 02 cannot be
performed with the SeusCam.
3.
Input of Board Type Data
Write the board type data in the EEPROM (nonvolatile memory).
Page
1C
Address
72, 73
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 01.
3) Input the following data to page: C, addresses: 72 and 73
Note:
Press the PAUSE button of the adjustment remote com-
mander each time to set the data.
MD-114 board:
Address
Data
72
02
73
02
MD-120 board:
Address
Data
72
08
73
08
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
6-19
DCR-DVD202E/DVD203/DVD203E/DVD703/DVD703E
4.
C Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 24
Fixed data-1 (Initialized data)
25
87
87
S VIDEO OUT Y level adj.
26
70
70
S VIDEO OUT chroma level adj.
27
50
50
28 to 3B
Fixed data-1 (Initialized data)
3C
Fixed data-2
3D, 3E
Fixed data-1 (Initialized data)
3F
6C
7A
VCO adj. (EVF)
40
90
80
41 to 44
Fixed data-1 (Initialized data)
45
7E
7E
White balance adj. (EVF)
46
7B
7B
47
58
58
Contrast adj. (EVF)
48 to 4A
Fixed data-1 (Initialized data)
4B
Fixed data-2
4C
Fixed data-1 (Initialized data)
4D
Fixed data-2
4E, 4F
Fixed data-1 (Initialized data)
50
6C
78
VCO adj. (LCD)
51
90
80
52
B6
B6
V-COM adj. (LCD)
53 to 55
Fixed data-1 (Initialized data)
56
83
83
Transmissive mode white balance
57
7F
7F
adj. (LCD)
58
5E
5E
Contrast adj. (LCD)
59 to 5C
Fixed data-1 (Initialized data)
5D
Fixed data-2
5E to 65
Fixed data-1 (Initialized data)
66
67
Fixed data-2
68 to 78
Fixed data-1 (Initialized data)
79
7A
Fixed data-2
7B
8E
8E
Reflective mode white balance adj.
7C
87
87
(LCD)
7D, 7E
Fixed data-1 (Initialized data)
7F
Fixed data-2
80
91
8E
IC2801 LINE OUT Y gain adj.
81
AD
AF
IC2801 LINE OUT chroma gain adj.
82
7B
7D
83
00
00
84
00
00
IC2801 adj.
85
00
00
Address
Initial value
Remark
NTSC PAL
86
00
00
87
0C
0F
88
36
46
IC2801 adj.
89
F8
18
8A
20
21
8B to 98
Fixed data-1 (Initialized data)
99
85
8A
IC2801 adj.
9A to A0
Fixed data-1 (Initialized data)
A1
20
20
A2
20
20
IC2801 adj.
A3
20
20
A4 to E3
Fixed data-1 (Initialized data)
E4
Fixed data-2
E5 to F1
Fixed data-1 (Initialized data)
F2
Fixed data-2
F3 to FF
Fixed data-1 (Initialized data)
6-20
DCR-DVD202E/DVD203/DVD203E/DVD703/DVD703E
5.
1C Page table
Note 1:
If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to“00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 21
Fixed data-1 (Initialized data)
22
23
Fixed data-2
24, 25
Fixed data-1 (Initialized data)
26
27
Fixed data-2
28 to 58
Fixed data-1 (Initialized data)
59
Fixed data-2
5A to 60
Fixed data-1 (Initialized data)
61
Fixed data-2
62 to 6B
Fixed data-1 (Initialized data)
6C
Fixed data-2
6D to 71
Fixed data-1 (Initialized data)
72
02
02
Refer to “3. Input of Board Type
Data” of “1-2-3. Initialization of C,
73
02
02
1C Page Data”.
74 to D5
Fixed data-1 (Initialized data)
D6
Fixed data-2
D7 to F4
Fixed data-1 (Initialized data)
F5
Fixed data-2
F6
Fixed data-1 (Initialized data)
F7
F8
Fixed data-2
F9 to FF
Fixed data-1 (Initialized data)
Page of 82
Display

Click on the first or last page to see other DCR-DVD202E / DCR-DVD203 / DCR-DVD203E / DCR-DVD703 / DCR-DVD703E (serv.man4) service manuals if exist.