DOWNLOAD Sony DCR-DVD101 / DCR-DVD101E / DCR-DVD91E (serv.man4) Service Manual ↓ Size: 867.67 KB | Pages: 49 in PDF or view online for FREE

Model
DCR-DVD101 DCR-DVD101E DCR-DVD91E (serv.man4)
Pages
49
Size
867.67 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd101-dcr-dvd101e-dcr-dvd91e-sm4.pdf
Date

Sony DCR-DVD101 / DCR-DVD101E / DCR-DVD91E (serv.man4) Service Manual ▷ View online

6-23
DCR-DVD91E/DVD101/DVD101E
10. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
19
Note1:
This adjustment should be carried out upon completion of “Flange
back adjustment” and “Optical Axis Adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4:
NTSC model : DCR-DVD101
PAL model
: DCR-DVD91E/DVD101E
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
02
Set the data.
3
6
96
Set the following data.
28 (NTSC), 1C (PAL)
4
6
97
Set the following data.
80 (NTSC), 00 (PAL)
5
6
01
6F
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01” within 30 sec. (Note5)
Note5:
The adjustment data will be automatically input to page: F, address:
19.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
6
96
00
Set the data.
3
6
97
00
Set the data.
4
6
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
11. LV Standard Data Input
And adjust the normal coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FB0 to 1050
Note1:
This adjustment should be carried out upon completion of “Flange
back adjustment”,  “Optical Axis Adjustment” and “Color
Reproduction Adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
   Display data
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
02
Set the data.
3
6
01
0D
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01” within 20 sec. (Note5)
5
0
03
1E
Set the data.
6
1
Check that the display data (Note5)
satisfies the specified value.
Note5:
The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
03
00
Set the data.
4
0
01
00
Set the data.
5
Perform “Auto White Balance
Standard Data Input”.
6-24
DCR-DVD91E/DVD101/DVD101E
12. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
2A to 2D
Note1:
This adjustment should be carried out upon completion of “Flange
back adjustment”,  “Optical Axis Adjustment” and “Color
reproduction adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
02
Set the data.
3
Wait for 2 sec.
4
6
01
11
Set the data, and press PAUSE
button.
5
6
01
0B
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
2A to 2D.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
01
00
Set the data.
4
Perform “Auto White Balance
Adjustment”.
13. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
2E to 31, 3E to 41
Note1:
This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4:
NTSC model : DCR-DVD101
PAL model
: DCR-DVD91E/DVD101E
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
6
48
02
Set the data.
4
F
3E
Set the following data, and press
PAUSE button.
28 (NTSC), 29 (PAL)
5
F
3F
00
Set the following data, and press
PAUSE button.
00 (NTSC), C0 (PAL)
6
F
40
Set the following data, and press
PAUSE button.
5E (NTSC), 5B (PAL)
7
F
41
00
Set the data, and press PAUSE
button.
8
6
01
83
Set the data, and press PAUSE
button.
9
6
01
81
Set the data, and press PAUSE
button.
10
6
02
Check that the data changes to
“01”. (Note5)
Note5:
The adjustment data will be automatically input to page: F, address:
2E to 31.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
01
00
Set the data.
4
Perform “White Balance Check”.
6-25
DCR-DVD91E/DVD101/DVD101E
14. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video terminal of
Display data
AUDIO/VIDEO
of page 1 (Note3)
jack
Measuring Instrument
Vectorscope
Adjustment
remote commander
Specified Value 1
Fig. 6-1-13. A to B
Specified Value 2
R ratio : 27B0 to 2840 (NTSC)
28B0 to 2940 (PAL)
B ratio : 5DB0 to 5E40 (NTSC)
5AB0 to 5B40 (PAL)
Specified Value 3
8000 to 8BC0
Note1:
Perform “Auto White Balance Adjustment” before this adjustment.
If not performed, R ratio data and B ratio data may not satisfy the
specified value 2.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note4:
NTSC model : DCR-DVD101
PAL model
: DCR-DVD91E/DVD101E
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Checking method:
Order Page Address Data
Procedure
Indoor white balance check
1
Check that the lens is not covered
with either filter.
2
6
48
02
Set the data.
3
6
01
0F
Set the data, and press PAUSE
button.
4
Check that the center of the white
luminance point is within the
circle shown Fig. 6-1-13. A.
5
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
6
Place the C14 filter on the lens.
7
6
01
3F
Set the data, and press PAUSE
button.
8
Check that the center of the white
luminance point is within the
circle shown Fig. 6-1-13. B.
9
0
03
04
Set the data.
10
1
Check that the display data
(Note3) satisfies the R ratio
specified value.
11
0
03
05
Set the data.
12
1
Check that the display data
(Note3) satisfies the B ratio
specified value.
13
Remove the C14 filter.
LV data check
14
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
15
6
01
00
Set the data, and press PAUSE
button.
16
0
03
06
Set the data.
17
1
Check that the display data
(Note3) satisfies the specified
value 3.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
48
00
Set the data.
4
Remove the ND filter.
R-Y
2mm
B-Y
2mm
R-Y
B-Y 
0.5mm
1mm
3mm
3mm
Fig. 6-1-13 (A).
Fig. 6-1-13 (B).
6-26
DCR-DVD91E/DVD101/DVD101E
15. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A : ENC03MA
Type B : ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2680 to 5080
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (Menu setting) ....................................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(SE-143 board SE5502)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
Yaw sensor check
(SE-143 board SE5501)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
5
0
03
00
Set the data.
6
Move the camcorder, and check
that the steady shot operations
have been performed normally
Note3:
Don’t move the camcorder.
Page of 49
Display

Click on the first or last page to see other DCR-DVD101 / DCR-DVD101E / DCR-DVD91E (serv.man4) service manuals if exist.