DOWNLOAD Sony DCR-DVD101 / DCR-DVD101E / DCR-DVD91E (serv.man4) Service Manual ↓ Size: 867.67 KB | Pages: 49 in PDF or view online for FREE

Model
DCR-DVD101 DCR-DVD101E DCR-DVD91E (serv.man4)
Pages
49
Size
867.67 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd101-dcr-dvd101e-dcr-dvd91e-sm4.pdf
Date

Sony DCR-DVD101 / DCR-DVD101E / DCR-DVD91E (serv.man4) Service Manual ▷ View online

6-19
DCR-DVD91E/DVD101/DVD101E
6. Optical Axis Adjustment
Align the lens Optical Axis with that of the CCD imager. If deviated,
center of picture can lose focus when zoom is operated from the
WIDE end to the TELE end.
Subject
Siemens star
Measurement Point
Check on the monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
5A
Note1:
This adjustment should be carried out upon completion of “Flange
back adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 48 is “00”. If not, set data:
00 to this address.
Note4:
NTSC model : DCR-DVD101
PAL model
: DCR-DVD91E/DVD101E
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
DIGITAL ZOOM (Menu setting) .................................... OFF
3)
STEADY SHOT (Menu setting) ...................................... OFF
Preparations before adjustments:
1)
Connect a DV camcorder to  the monitor TV.
2)
Playback the monoscope segment of the system check tape
(XH5-5(NTSC), XH5-5P(PAL),).
3)
Attach the optical axis frame chart (transparent) on the monitor
TV screen. Center of monoscope image and that of optical axis
frame must be agree.
4)
Disconnect the DV camcorder from the monitor TV, and
connect the DVD camcorder to the monitor TV.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 5A, set data: 00, and press the PAUSE
button.
3)
Place the Siemens star 2.0 m away from the front of the lens.
4)
Shoot the Siemens star with the zoom TELE end.
5)
Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
6)
Shoot the Siemens star with the zoom WIDE end.
7)
Measure on the monitor TV screen in which area of the optical
axis frame the center of the Siemens star is located. Measure
the amount of displacement (distance between the center of
the Siemens star and the center of the optical axis frame.) The
measurement value is named L1.
8)
Read the correction data corresponding to the area from Table
6-1-8.
9)
Input the correction data to page: F, address: 5A, and press the
PAUSE button
10) Shoot the Siemens star with the zoom TELE end.
11) Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
12) Shoot the Siemens star with the zoom WIDE end.
13) Measure the amount of displacement (distance between the
center of the Siemens star and the center of the optical axis
frame.) The measurement value is named L2.
14) Compare the values L1 and L2, and confirm that L2 is smaller
than L1. If L2 is lager than L1, select page: F, address: 5A, set
data: 00, and press the PAUSE button.
Table 6-1-10.
Processing after Completing Adjustments:
1)
Select page: 0, address: 01, and set data: 00.
Fig. 6-1-8.
Area
1
2
3
4
5
6
7
8
Correction data
(Page: F, address: 5A)
01
02
03
04
05
06
07
08
Display phase
22.6
°
 to 67.5
°
67.6
°
 to 112.5
°
112.6
°
 to 157.5
°
157.6
°
 to 202.5
°
202.6
°
to 247.5
°
247.6
°
 to 292.5
°
292.6
°
 to 337.5
°
337.6
°
 to 22.5
°
6-20
DCR-DVD91E/DVD101/DVD101E
7. Mechanical Shutter Adjustment
Adjustment Page
F
Adjustment Address
5C to 71
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
NTSC model : DCR-DVD101
PAL model
: DCR-DVD91E/DVD101E
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 5C to 71.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Select page: 0, address: 01, and set data: 00.
PAL
80
80
80
80
80
80
40
00
34
00
30
00
2A
00
14
00
70
80
80
80
80
1E
Address
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
NTSC
80
80
80
80
80
80
40
00
34
00
30
00
2A
00
14
00
70
80
80
80
80
1E
Data
6-21
DCR-DVD91E/DVD101/DVD101E
8. Picture Frame Setting
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.0m from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Note1:
The following adjustments should be carried out upon completion
of “Flange back adjustment” and “Optical Axis Adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Setting method:
1)
Select page: 6, address: 48, and set data: 02.
2)
Adjust the zoom and the camera direction, and set to the
specified position.
3)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
Processing after Completing Camera System Adjustments:
After completing the camera system adjustments, release the data
settings.
1)
Select page: 6, address: 48, and set data: 00.
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-9.
2. Vertical period
Fig. 6-1-10.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-11.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
6-22
DCR-DVD91E/DVD101/DVD101E
9. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
33, 35, 3A, 3B
Specified Value
All color luminance points should settle
within each color reproduction frame.
Note1:
This adjustment should be carried out upon completion of “Flange
back adjustment” and “Optical Axis Adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
NTSC model : DCR-DVD101
PAL model
: DCR-DVD91E/DVD101E
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 48, and set data: 02.
3)
Select page: 6, address: 9D, set the following data, and press
the PAUSE button.
82 (NTSC), 89 (PAL)
4)
Select page: 6, address: 01, set data: 3D, and press the PAUSE
button.
5)
Select page: F, address: 80, set the following data, and press
the PAUSE button.
37 (NTSC), B7 (PAL)
6)
Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
7)
Change the data of page: F, address: 33, 35, 3A and 3B, and
settle each color luminance point in each color reproduction
frame.
Note:
Be sure to press the PAUSE button of the adjustment remote
commander before changing the addresses. If not, the new data
will not be written to the memory.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 6, address: 48, and set data: 00.
3)
Select page: 6, address: 9D, and set data: 00.
4)
Select page: 0, address: 01, and set data: 00.
Burst position
For NTSC model
Burst position
For PAL model
Fig. 6-1-12.
Page of 49