DOWNLOAD Sony DCR-DVD100 / DCR-DVD100E (serv.man4) Service Manual ↓ Size: 933.62 KB | Pages: 52 in PDF or view online for FREE

Model
DCR-DVD100 DCR-DVD100E (serv.man4)
Pages
52
Size
933.62 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd100-dcr-dvd100e-sm4.pdf
Date

Sony DCR-DVD100 / DCR-DVD100E (serv.man4) Service Manual ▷ View online

6-15
DCR-DVD100/DVD100E
3. Flange Back Adjustment (Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
32 to 42
Note1:
Dark Siemens star chart.
Note2:
This adjustment should be carried out upon completion of “HALL
Adjustment”.
Note3:
Make the lens horizontal and perform this adjustment.
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note:
The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage:
The specified voltage varies according to the minipattern box, so
adjust the power supply output voltage to the specified voltage
written on the sheet which is supplied with the minipattern box.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button. (Note3)
4
6
01
27
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note6)
Note6:
The adjustment data will be automatically input to page: F, address:
32 to 42.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”.
Fig. 6-1-7.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
6-16
DCR-DVD100/DVD100E
4. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
4-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass)
(Luminance: 350 
±
 50 lux)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
32 to 42
Note1:
This adjustment should be carried out upon completion of “HALL
Adjustment”.
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, turn off
the power and turn on again.
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
Preparations:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button. (Note2)
4
6
01
15
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note5)
Note5:
The adjustment data will be automatically input to page: F, address:
32 to 42.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
Turn off the power and turn on
again.
2
Perform “Flange Back
Adjustment (2)”
4-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
32 to 42
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”, turn off the
power and turn on again.
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
01
Set the data.
3
6
01
13
Set the data, and press PAUSE
button. (Note2)
4
Place a ND filter on the lens so
that the optimum image is obtain.
5
6
01
29
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
32 to 42.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again.
4
Perform “Flange Back Check”
6-17
DCR-DVD100/DVD100E
5. Flange Back Check
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Note1:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
NIGHT SHOT .................................................................. OFF
Note2:
When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
1)
Select page: 6, address: 40, and set data: 01.
2)
Select page: 6, address: 41, and set data: 01.
3)
Place the Siemens star 2.0m from the front of the lens.
4)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
5)
Shoot the Siemens star with the zoom TELE end.
6)
Turn on the auto focus.
7)
Check that the lens is focused (Note2).
8)
Select page: 6, address: 21, and set data: 10.
9)
Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.
6-18
DCR-DVD100/DVD100E
6. Optical Axis Adjustment
Align the lens Optical Axis with that of the CCD imager. If deviated,
center of picture can lose focus when zoom is operated from the
WIDE end to the TELE end.
Subject
Siemens star
Measurement Point
Check on the monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
46
Note1:
This adjustment should be carried out upon completion of “Flange
back adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 48 is “00”. If not, set data:
00 to this address.
Note4:
NTSC model: DCR-DVD100
PAL model: DCR-DVD100E
Switch setting:
1)
MODE ............................................................. MOVIE ( 
 )
2)
DIGITAL ZOOM (Menu setting) .................................... OFF
3)
STEADY SHOT (Menu setting) ...................................... OFF
Preparations before adjustments:
1)
Connect a DV camcorder to the monitor TV.
2)
Playback the monoscope segment of the DV system check tape
(XH5-5 (NTSC), XH5-5P (PAL),).
3)
Attach the optical axis frame chart (transparent) on the monitor
TV screen. Center of monoscope image and that of optical axis
frame must be agree.
4)
Disconnect the DV camcorder from the monitor TV, and
connect the DVD camcorder to the monitor TV.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 46, set data: 00, and press the PAUSE
button.
3)
Place the Siemens star 2.0 m away from the front of the lens.
4)
Shoot the Siemens star with the zoom TELE end.
5)
Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
6)
Shoot the Siemens star with the zoom WIDE end.
7)
Measure on the monitor TV screen in which area of the optical
axis frame the center of the Siemens star is located. Measure
the amount of displacement (distance between the center of
the Siemens star and the center of the optical axis frame.) The
measurement value is named L1.
8)
Read the correction data corresponding to the area from Table
6-1-9.
9)
Input the correction data to page: F, address: 46, and press the
PAUSE button
10) Shoot the Siemens star with the zoom TELE end.
11) Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
12) Shoot the Siemens star with the zoom WIDE end.
13) Measure the amount of displacement (distance between the
center of the Siemens star and the center of the optical axis
frame.) The measurement value is named L2.
14) Compare the values L1 and L2, and confirm that L2 is smaller
than L1. If L2 is lager than L1, select page: F, address: 46, set
data: 00, and press the PAUSE button.
Table 6-1-9.
Processing after Completing Adjustments:
1)
Select page: 0, address: 01, and set data: 00.
Fig. 6-1-8.
Area
1
2
3
4
5
6
7
8
Correction data
(Page: F, address: 46)
01
02
03
04
05
06
07
08
Display phase
22.6
°
 to 67.5
°
67.6
°
 to 112.5
°
112.6
°
 to 157.5
°
157.6
°
 to 202.5
°
202.6
°
to 247.5
°
247.6
°
 to 292.5
°
292.6
°
 to 337.5
°
337.6
°
 to 22.5
°
Page of 52
Display